Corrosion failure assessment on AISI 310s steel used as support of refractory concrete panels in a clinker cooler
This article presents the corrosion failure assessment on AISI 310 Steel, used as support of refractory concrete panels in a Clinker cooler under a combination of high temperatures and atmospheres with high concentration of sulfur and carbon. It was performed a microstructural analysis by scanning e...