Alternative generation of the output voltage waveform in an asymmetric transformer-based cascaded multilevel inverter under fault conditions

This paper introduces a method for the reconfiguration of a transformer-based cascaded multilevel inverter (CT-MLI), which allows the use of alternative switching patterns when individual inverter stages cease to operate as a result of a failure in the circuit switches. Different possibilities of re...

Full description

Autores:
Inostroza-Osses, Mauricio A.
López-Santos, Oswaldo
Aldana-Rodríguez, Yeison A.
Forero, Manuel G.
Tipo de recurso:
Article of journal
Fecha de publicación:
2022
Institución:
Universidad de Ibagué
Repositorio:
Repositorio Universidad de Ibagué
Idioma:
eng
OAI Identifier:
oai:repositorio.unibague.edu.co:20.500.12313/3844
Acceso en línea:
https://hdl.handle.net/20.500.12313/3844
Palabra clave:
Automatic reconfiguration
Fault tolerant operation
Multilevel inverters
Transformer-based cascade multilevel inverters
Rights
openAccess
License
http://purl.org/coar/access_right/c_abf2
Description
Summary:This paper introduces a method for the reconfiguration of a transformer-based cascaded multilevel inverter (CT-MLI), which allows the use of alternative switching patterns when individual inverter stages cease to operate as a result of a failure in the circuit switches. Different possibilities of reconfiguration of the inverter stages to provide the output voltage signal are analyzed and optimal switching patterns are determined. The results obtained from the simulation in the PSIM software are provided to validate the proposal