Alternative generation of the output voltage waveform in an asymmetric transformer-based cascaded multilevel inverter under fault conditions
This paper introduces a method for the reconfiguration of a transformer-based cascaded multilevel inverter (CT-MLI), which allows the use of alternative switching patterns when individual inverter stages cease to operate as a result of a failure in the circuit switches. Different possibilities of re...
- Autores:
-
Inostroza-Osses, Mauricio A.
López-Santos, Oswaldo
Aldana-Rodríguez, Yeison A.
Forero, Manuel G.
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2022
- Institución:
- Universidad de Ibagué
- Repositorio:
- Repositorio Universidad de Ibagué
- Idioma:
- eng
- OAI Identifier:
- oai:repositorio.unibague.edu.co:20.500.12313/3844
- Acceso en línea:
- https://hdl.handle.net/20.500.12313/3844
- Palabra clave:
- Automatic reconfiguration
Fault tolerant operation
Multilevel inverters
Transformer-based cascade multilevel inverters
- Rights
- openAccess
- License
- http://purl.org/coar/access_right/c_abf2