Alternative generation of the output voltage waveform in an asymmetric transformer-based cascaded multilevel inverter under fault conditions

This paper introduces a method for the reconfiguration of a transformer-based cascaded multilevel inverter (CT-MLI), which allows the use of alternative switching patterns when individual inverter stages cease to operate as a result of a failure in the circuit switches. Different possibilities of re...

Full description

Autores:
Inostroza-Osses, Mauricio A.
López-Santos, Oswaldo
Aldana-Rodríguez, Yeison A.
Forero, Manuel G.
Tipo de recurso:
Article of journal
Fecha de publicación:
2022
Institución:
Universidad de Ibagué
Repositorio:
Repositorio Universidad de Ibagué
Idioma:
eng
OAI Identifier:
oai:repositorio.unibague.edu.co:20.500.12313/3844
Acceso en línea:
https://hdl.handle.net/20.500.12313/3844
Palabra clave:
Automatic reconfiguration
Fault tolerant operation
Multilevel inverters
Transformer-based cascade multilevel inverters
Rights