Stability criteria and critical runway conditions of propylene glycol manufacture in a continuous stirred tank reactor
Here, a new method for the analysis of the steady state and the safety operational conditions of the hydrolysis of propylene oxide with excess of water, in a Continuous Stirred Tank Reactor (CSTR), was developed. For industrial operational typical values, at first, the generated and removed heat bal...
- Autores:
-
Gómez, Miguel Ángel
López Zamora, Sandra Milena
Gómez, Isabel Dobrosz
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2015
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/67668
- Acceso en línea:
- https://repositorio.unal.edu.co/handle/unal/67668
http://bdigital.unal.edu.co/68697/
- Palabra clave:
- 62 Ingeniería y operaciones afines / Engineering
stability criteria
propylene oxide
propylene glycol
runaway conditions.
Criterios de estabilidad
óxido de propileno
propilen glicol
condiciones de runaway.
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional