Numerical and experimental preliminary study of temperature distribution in an electric resistance tube furnace for hot compression tests

Hot compression tests are performed when jaws, each one with a jacketed section to cool a part of its length, move through a tube furnace at elevated temperatures to compress a metal sample between them, changing the boundary conditions and the temperature distribution inside the furnace during the...

Full description

Autores:
Torrente-Prato, Gabriel
Torres-Rodríguez, Mary
Tipo de recurso:
Article of journal
Fecha de publicación:
2014
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/48965
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/48965
http://bdigital.unal.edu.co/42422/
Palabra clave:
hot compression tests
electric resistance tube furnaces
temperature distribution
heat balance
convection
radiation
Rights
openAccess
License
Atribución-NoComercial 4.0 Internacional