Optimal design for rectangular isolated footings using the real soil pressure

The standard design method (classical method) for reinforced concrete rectangular footings is: First, a dimension is proposed and should comply with the allowable stresses; subsequently, the effective depth is obtained from the maximum moment and is checked against the bending shear and the punching...

Full description

Autores:
Luévanos Rojas, Arnulfo
López Chavarría, S
Medina Elizondo, M
Tipo de recurso:
Article of journal
Fecha de publicación:
2017
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/67577
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/67577
http://bdigital.unal.edu.co/68606/
Palabra clave:
62 Ingeniería y operaciones afines / Engineering
optimal design
reinforced concrete rectangular footings
minimum cost design
moments
bending shear
punching shear
Diseño óptimo
zapatas rectangulares de concreto reforzado
diseño de costo mínimo
momentos
cortante por flexión
cortante por punzonamiento
Rights
openAccess
License