Determinación de calidad del ensayo de tensión en acero mediante estudios de reproducibilidad y repetibilidad

Este proyecto plantea el análisis y procedimiento de repetibilidad, reproducibilidad e incertidumbre para el ensayo de acero corrugado para varilla de diámetros bajo los estándares de la norma NTC 2289 (NORMA TÉCNICA COLOMBIANA). Para estudios de repetibilidad se ensayaron 6 muestras de varilla de d...

Full description

Autores:
Barbosa Ortiz, Yeni Del Pilar
Dallos Rincon, Fredy Leonardo
Tipo de recurso:
http://purl.org/coar/version/c_b1a7d7d4d402bcce
Fecha de publicación:
2016
Institución:
Universidad Industrial de Santander
Repositorio:
Repositorio UIS
Idioma:
spa
OAI Identifier:
oai:noesis.uis.edu.co:20.500.14071/34037
Acceso en línea:
https://noesis.uis.edu.co/handle/20.500.14071/34037
https://noesis.uis.edu.co
Palabra clave:
Ensayo De Tensión En Acero
Repetibilidad De Los Resultados De Medición
Reproducibilidad De Los Resultados De Medición
Incertidumbre
Tolerancia.
This project proposes the analysis and the procedures of repeatability
reproducibility and uncertainty for the test of corrugated steel for rod with diameters " and under the standards of standard NTC 2289 (COLOMBIAN TECHNICAL STANDARD). For repeatability studies
six diameter rod samples were tested. For rods of diameter " and
twelve rod samples were tested
respectively
taking into account that each rod diameter has its respective test clamp in the materials characterization laboratory of the Industrial University of Santander. For reproducibility studies
four samples were tested for each rod diameter
respectively
two in the materials characterization laboratory of the Industrial University of Santander
in the same way
two samples of rod were tested for each diameter respectively in the external laboratory (Andes University Civil Engineering laboratory)
certified by the ONAC (National Accreditation Organization of Colombia). Using different statistical methods likes ranges and averages to obtained a percentages of repeatability
reproducibility and r&R percentages. The Gum guide was used to estimate an uncertainty with a 95% confidence level
this method was applied only for " and diameter rod samples
respectively
in the repeatability test performed in the materials characterization laboratory of the Industrial University of Santander.
Rights