Diseño de un sistema de control Fuzzy para el manejo de una ortesis de la rodilla activa simula en un entorno 3D

The present comprehensive degree work develops a control system focused on the rehabilitation of the knee, the control is reflected in the monitoring of the angular movement. Said angular movement is observed thanks to the active orthosis designed and simulated in a 3D environment, this, with the fu...

Full description

Autores:
Villota Betancourth, Harold David
Nieto Ortiz, Ingrid Tatiana
Tipo de recurso:
Trabajo de grado de pregrado
Fecha de publicación:
2023
Institución:
Universidad Antonio Nariño
Repositorio:
Repositorio UAN
Idioma:
spa
OAI Identifier:
oai:repositorio.uan.edu.co:123456789/8405
Acceso en línea:
http://repositorio.uan.edu.co/handle/123456789/8405
Palabra clave:
Rehabilitación de rodilla
Control Fuzzy
Ortesis 3D
56.23 V761d
Knee rehabilitation
Fuzzy Control
3D Orthosis
Rights
openAccess
License
Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
id UAntonioN2_b1b2efbad25a8a267c6da276379dc862
oai_identifier_str oai:repositorio.uan.edu.co:123456789/8405
network_acronym_str UAntonioN2
network_name_str Repositorio UAN
repository_id_str
dc.title.es_ES.fl_str_mv Diseño de un sistema de control Fuzzy para el manejo de una ortesis de la rodilla activa simula en un entorno 3D
title Diseño de un sistema de control Fuzzy para el manejo de una ortesis de la rodilla activa simula en un entorno 3D
spellingShingle Diseño de un sistema de control Fuzzy para el manejo de una ortesis de la rodilla activa simula en un entorno 3D
Rehabilitación de rodilla
Control Fuzzy
Ortesis 3D
56.23 V761d
Knee rehabilitation
Fuzzy Control
3D Orthosis
title_short Diseño de un sistema de control Fuzzy para el manejo de una ortesis de la rodilla activa simula en un entorno 3D
title_full Diseño de un sistema de control Fuzzy para el manejo de una ortesis de la rodilla activa simula en un entorno 3D
title_fullStr Diseño de un sistema de control Fuzzy para el manejo de una ortesis de la rodilla activa simula en un entorno 3D
title_full_unstemmed Diseño de un sistema de control Fuzzy para el manejo de una ortesis de la rodilla activa simula en un entorno 3D
title_sort Diseño de un sistema de control Fuzzy para el manejo de una ortesis de la rodilla activa simula en un entorno 3D
dc.creator.fl_str_mv Villota Betancourth, Harold David
Nieto Ortiz, Ingrid Tatiana
dc.contributor.advisor.spa.fl_str_mv Quinayás Burgos, César Augusto
dc.contributor.author.spa.fl_str_mv Villota Betancourth, Harold David
Nieto Ortiz, Ingrid Tatiana
dc.subject.es_ES.fl_str_mv Rehabilitación de rodilla
Control Fuzzy
Ortesis 3D
topic Rehabilitación de rodilla
Control Fuzzy
Ortesis 3D
56.23 V761d
Knee rehabilitation
Fuzzy Control
3D Orthosis
dc.subject.ddc.es_ES.fl_str_mv 56.23 V761d
dc.subject.keyword.es_ES.fl_str_mv Knee rehabilitation
Fuzzy Control
3D Orthosis
description The present comprehensive degree work develops a control system focused on the rehabilitation of the knee, the control is reflected in the monitoring of the angular movement. Said angular movement is observed thanks to the active orthosis designed and simulated in a 3D environment, this, with the future objective of creating a capable device in order to automate part of a complete rehabilitation therapy, specifically in passive therapy, which is where the patient needs external help to flex - extend the leg and gradually recover the range of motion. Normally, for any knee injury, a rehabilitation and recovery therapy plan is needed. To give a context of the problem about the lack of automation, we begin by describing a traditional knee rehabilitation therapy, initially the inflammation of the joint is reduced to start as soon as possible with small movements, the position of the patient depends on the professional manager since It can be sitting or lying down, but always looking for the comfort of both to be able to complete the primary exercises that are: Flexion and extension, this happens in passive kinesitherapy. Each time the arc of angular mobility must increase to observe an improvement, the ranges handled by physiotherapists go from 0-20°, 0-40°, 0-60°, 0-90° and the measurement of these angles is carried out by a tool called a goniometer. When inquiring into the rehabilitation process, we find that they do not use this tool and the recovery is subjective, since they depend on the reaction that is reflected in the patient to make decisions, that is, if they feel pain, they stop immediately with therapy until you can continue again. That is why the control system seeks to ensure the angle within the range of 0° to 90° and the movement can be observed in the active orthosis designed in 3D. For the design and development of the Fuzzy control system, the Matlab tool that goes hand in hand with the Simulink platform is used, this programming is done by means of blocks which will have input and output variables, that is why that other external microcontrollers are used for specific actions that will be seen in the development of this document. The active support orthosis is designed in a CAD program called SolidWorks, to then be taken to Simulink where the assembly is carried out in order to unify the entire control system and to be able to proceed with the manipulation. This is demonstrated in the results of the document.
publishDate 2023
dc.date.accessioned.none.fl_str_mv 2023-08-09T15:33:07Z
dc.date.available.none.fl_str_mv 2023-08-09T15:33:07Z
dc.date.issued.spa.fl_str_mv 2023-06-08
dc.type.spa.fl_str_mv Trabajo de grado (Pregrado y/o Especialización)
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_7a1f
dc.type.coarversion.none.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
format http://purl.org/coar/resource_type/c_7a1f
dc.identifier.uri.none.fl_str_mv http://repositorio.uan.edu.co/handle/123456789/8405
dc.identifier.bibliographicCitation.spa.fl_str_mv Almeida, A., Santana, R., Karelin, A., Daniel De La, J., Santisteban López, L. E., Florencia, M., Anglin, P., Gonzales, D. L., Zamora, I., Francisco, L. J., & Mesa, C. (2020). La articulación de la rodilla: lesión del ligamento cruzado anterior. Universidad de Ciencias Médicas de Granma., 1–97. https://docs.google.com/viewerng/viewer?url=https://revdosdic.sld.cu/index.php/revd osdic/article/viewFile/38/97
Alvarez Ajuria. (2017). REHABILITACIÓN DE LA ROTURA DEL LIGAMENTO CRUZADO ANTERIOR EN EL FÚTBOL. https://addi.ehu.es/bitstream/handle/10810/23475/TFG_ALVAREZ%2CA.pdf?seque nce=3&isAllowed=y Artromot K1 – Equipos Interferenciales. (2017). https://interferenciales.com.mx/products/artromot-k1
Basas Angel. (2017). Análisis de los efectos de un protocolo de electroestimulación y ejercicios excéntricos, isométricos y concéntricos sobre el dolor y la funcionalidad en el tratamiento y readaptación de la tendinopatía rotuliana o rodilla del saltador. https://oa.upm.es/45231/1/ANGEL_BASAS_GARCIA.pdf
Carlos, I. J., & Vergara, V. (2017). Diseño de un dispositivo de rehabilitacion de rodilla mediante optimizacion de mecanismos. Universidad autonoma del estado de mexico. http://ri.uaemex.mx/bitstream/handle/20.500.11799/79836/Tesis_Juan_Carlos_Villan ueva.pdf?sequence=1
Carpio Holguín, D. M. (2022). Desarrollo de un controlador neuro difuso sobre un sistema embebido y monitoreo remoto de variables a través de una plataforma iot. https://dspace.ups.edu.ec/bitstream/123456789/21895/4/UPS-GT003622.pdf
Cinesiterapia, el beneficio del movimiento - Tratamiento | Fisiolution. (2020). https://fisiolution.com/cinesiterapia-el-beneficio-del-movimiento/
CRUZ SÁNCHEZ ARI BERITH. (2020). INSTRUMENTACIÓN Y CONTROL DE UN PROTOTIPO DE EXOESQUELETO PARA MANO EN REHABILITACIÓN ASISTIDA. http://192.100.170.40/bitstream/123456789/301/1/2020-MR-BACS.pdf
Daniel Eduardo, & Pablo Fernando. (2018). diseño e implementaciòn de un control difuso de velocidad para motor hidraulico [Universidad Polictecnica Salesiana Sede Cuenca]. https://dspace.ups.edu.ec/bitstream/123456789/16369/1/UPS-CT007970.pdf
Erick Lemus. (2021, May 26). ¿Qué es una Ortesis de Rodilla y cómo funciona? - Miprotesisdepierna.mx. https://miprotesisdepierna.mx/blog/ortesis-de-rodilla/
M. Amirullah. (2015). Simulation of fuzzy logic control for DC servo motor using Arduino based on MATLAB/Simulink. Proceedings of 2014 International Conference on Intelligent Autonomous Agents, Networks and Systems, INAGENTSYS 2014, 42–46
Popular models | 3D CAD Model Collection | GrabCAD Community Library. (2023). https://grabcad.com/library
R. Chavez. (n.d.). Control de una prótesis mioelectrica de brazo por medio de Logica difusa. AOTS and Ricardo Palma University. Retrieved May 22, 2023, from https://www.urp.edu.pe/pdf/id/5798/n/control-una-protesis-mioelectrica-de-brazopor-medio-de-logica-difusa
Sabalbal, M., Johnson, M., & McAlister, V. (2013). Absence of the genicular arterial anastomosis as generally depicted in textbooks. Annals of the Royal College of Surgeons of England, 1–5. https://doi.org/10.1308/003588413X13629960046831
dc.identifier.instname.spa.fl_str_mv instname:Universidad Antonio Nariño
dc.identifier.reponame.spa.fl_str_mv reponame:Repositorio Institucional UAN
dc.identifier.repourl.spa.fl_str_mv repourl:https://repositorio.uan.edu.co/
url http://repositorio.uan.edu.co/handle/123456789/8405
identifier_str_mv Almeida, A., Santana, R., Karelin, A., Daniel De La, J., Santisteban López, L. E., Florencia, M., Anglin, P., Gonzales, D. L., Zamora, I., Francisco, L. J., & Mesa, C. (2020). La articulación de la rodilla: lesión del ligamento cruzado anterior. Universidad de Ciencias Médicas de Granma., 1–97. https://docs.google.com/viewerng/viewer?url=https://revdosdic.sld.cu/index.php/revd osdic/article/viewFile/38/97
Alvarez Ajuria. (2017). REHABILITACIÓN DE LA ROTURA DEL LIGAMENTO CRUZADO ANTERIOR EN EL FÚTBOL. https://addi.ehu.es/bitstream/handle/10810/23475/TFG_ALVAREZ%2CA.pdf?seque nce=3&isAllowed=y Artromot K1 – Equipos Interferenciales. (2017). https://interferenciales.com.mx/products/artromot-k1
Basas Angel. (2017). Análisis de los efectos de un protocolo de electroestimulación y ejercicios excéntricos, isométricos y concéntricos sobre el dolor y la funcionalidad en el tratamiento y readaptación de la tendinopatía rotuliana o rodilla del saltador. https://oa.upm.es/45231/1/ANGEL_BASAS_GARCIA.pdf
Carlos, I. J., & Vergara, V. (2017). Diseño de un dispositivo de rehabilitacion de rodilla mediante optimizacion de mecanismos. Universidad autonoma del estado de mexico. http://ri.uaemex.mx/bitstream/handle/20.500.11799/79836/Tesis_Juan_Carlos_Villan ueva.pdf?sequence=1
Carpio Holguín, D. M. (2022). Desarrollo de un controlador neuro difuso sobre un sistema embebido y monitoreo remoto de variables a través de una plataforma iot. https://dspace.ups.edu.ec/bitstream/123456789/21895/4/UPS-GT003622.pdf
Cinesiterapia, el beneficio del movimiento - Tratamiento | Fisiolution. (2020). https://fisiolution.com/cinesiterapia-el-beneficio-del-movimiento/
CRUZ SÁNCHEZ ARI BERITH. (2020). INSTRUMENTACIÓN Y CONTROL DE UN PROTOTIPO DE EXOESQUELETO PARA MANO EN REHABILITACIÓN ASISTIDA. http://192.100.170.40/bitstream/123456789/301/1/2020-MR-BACS.pdf
Daniel Eduardo, & Pablo Fernando. (2018). diseño e implementaciòn de un control difuso de velocidad para motor hidraulico [Universidad Polictecnica Salesiana Sede Cuenca]. https://dspace.ups.edu.ec/bitstream/123456789/16369/1/UPS-CT007970.pdf
Erick Lemus. (2021, May 26). ¿Qué es una Ortesis de Rodilla y cómo funciona? - Miprotesisdepierna.mx. https://miprotesisdepierna.mx/blog/ortesis-de-rodilla/
M. Amirullah. (2015). Simulation of fuzzy logic control for DC servo motor using Arduino based on MATLAB/Simulink. Proceedings of 2014 International Conference on Intelligent Autonomous Agents, Networks and Systems, INAGENTSYS 2014, 42–46
Popular models | 3D CAD Model Collection | GrabCAD Community Library. (2023). https://grabcad.com/library
R. Chavez. (n.d.). Control de una prótesis mioelectrica de brazo por medio de Logica difusa. AOTS and Ricardo Palma University. Retrieved May 22, 2023, from https://www.urp.edu.pe/pdf/id/5798/n/control-una-protesis-mioelectrica-de-brazopor-medio-de-logica-difusa
Sabalbal, M., Johnson, M., & McAlister, V. (2013). Absence of the genicular arterial anastomosis as generally depicted in textbooks. Annals of the Royal College of Surgeons of England, 1–5. https://doi.org/10.1308/003588413X13629960046831
instname:Universidad Antonio Nariño
reponame:Repositorio Institucional UAN
repourl:https://repositorio.uan.edu.co/
dc.language.iso.spa.fl_str_mv spa
language spa
dc.rights.none.fl_str_mv Acceso abierto
dc.rights.license.spa.fl_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
dc.rights.uri.spa.fl_str_mv https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
Acceso abierto
https://creativecommons.org/licenses/by-nc-nd/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.coverage.spatial.spa.fl_str_mv Colombia( Popayán, Cauca)
dc.publisher.spa.fl_str_mv Universidad Antonio Nariño
dc.publisher.program.spa.fl_str_mv Ingeniería Biomédica
dc.publisher.faculty.spa.fl_str_mv Facultad de Ingeniería Mecánica, Electrónica y Biomédica
dc.publisher.campus.spa.fl_str_mv Popayán - Alto Cauca
institution Universidad Antonio Nariño
bitstream.url.fl_str_mv https://repositorio.uan.edu.co/bitstreams/22a5400a-9bdf-455c-8f2e-ec1fdf6db5b4/download
https://repositorio.uan.edu.co/bitstreams/fab2985b-bc5b-4bcb-b5da-acc070c04713/download
https://repositorio.uan.edu.co/bitstreams/aec66fb9-6334-4cc0-a6bf-d31109e8bf99/download
https://repositorio.uan.edu.co/bitstreams/2e249abb-9d71-4266-8456-4d66e75bdfdf/download
https://repositorio.uan.edu.co/bitstreams/98378db4-102f-483d-926f-d1059a863679/download
bitstream.checksum.fl_str_mv 0ccf19ae350bcdc643c7c257cf794fa0
619ac2a3744a5a7bcc82998ea1f81cee
2d766f62a2c248dd0d0e67ca32ef816c
99733c46a6995ebcf5aee1734c41dedd
9868ccc48a14c8d591352b6eaf7f6239
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional UAN
repository.mail.fl_str_mv alertas.repositorio@uan.edu.co
_version_ 1814300356827414528
spelling Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)Acceso abiertohttps://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Quinayás Burgos, César AugustoVillota Betancourth, Harold DavidNieto Ortiz, Ingrid Tatiana2056181720320561812410Colombia( Popayán, Cauca)2023-08-09T15:33:07Z2023-08-09T15:33:07Z2023-06-08http://repositorio.uan.edu.co/handle/123456789/8405Almeida, A., Santana, R., Karelin, A., Daniel De La, J., Santisteban López, L. E., Florencia, M., Anglin, P., Gonzales, D. L., Zamora, I., Francisco, L. J., & Mesa, C. (2020). La articulación de la rodilla: lesión del ligamento cruzado anterior. Universidad de Ciencias Médicas de Granma., 1–97. https://docs.google.com/viewerng/viewer?url=https://revdosdic.sld.cu/index.php/revd osdic/article/viewFile/38/97Alvarez Ajuria. (2017). REHABILITACIÓN DE LA ROTURA DEL LIGAMENTO CRUZADO ANTERIOR EN EL FÚTBOL. https://addi.ehu.es/bitstream/handle/10810/23475/TFG_ALVAREZ%2CA.pdf?seque nce=3&isAllowed=y Artromot K1 – Equipos Interferenciales. (2017). https://interferenciales.com.mx/products/artromot-k1Basas Angel. (2017). Análisis de los efectos de un protocolo de electroestimulación y ejercicios excéntricos, isométricos y concéntricos sobre el dolor y la funcionalidad en el tratamiento y readaptación de la tendinopatía rotuliana o rodilla del saltador. https://oa.upm.es/45231/1/ANGEL_BASAS_GARCIA.pdfCarlos, I. J., & Vergara, V. (2017). Diseño de un dispositivo de rehabilitacion de rodilla mediante optimizacion de mecanismos. Universidad autonoma del estado de mexico. http://ri.uaemex.mx/bitstream/handle/20.500.11799/79836/Tesis_Juan_Carlos_Villan ueva.pdf?sequence=1Carpio Holguín, D. M. (2022). Desarrollo de un controlador neuro difuso sobre un sistema embebido y monitoreo remoto de variables a través de una plataforma iot. https://dspace.ups.edu.ec/bitstream/123456789/21895/4/UPS-GT003622.pdfCinesiterapia, el beneficio del movimiento - Tratamiento | Fisiolution. (2020). https://fisiolution.com/cinesiterapia-el-beneficio-del-movimiento/CRUZ SÁNCHEZ ARI BERITH. (2020). INSTRUMENTACIÓN Y CONTROL DE UN PROTOTIPO DE EXOESQUELETO PARA MANO EN REHABILITACIÓN ASISTIDA. http://192.100.170.40/bitstream/123456789/301/1/2020-MR-BACS.pdfDaniel Eduardo, & Pablo Fernando. (2018). diseño e implementaciòn de un control difuso de velocidad para motor hidraulico [Universidad Polictecnica Salesiana Sede Cuenca]. https://dspace.ups.edu.ec/bitstream/123456789/16369/1/UPS-CT007970.pdfErick Lemus. (2021, May 26). ¿Qué es una Ortesis de Rodilla y cómo funciona? - Miprotesisdepierna.mx. https://miprotesisdepierna.mx/blog/ortesis-de-rodilla/M. Amirullah. (2015). Simulation of fuzzy logic control for DC servo motor using Arduino based on MATLAB/Simulink. Proceedings of 2014 International Conference on Intelligent Autonomous Agents, Networks and Systems, INAGENTSYS 2014, 42–46Popular models | 3D CAD Model Collection | GrabCAD Community Library. (2023). https://grabcad.com/libraryR. Chavez. (n.d.). Control de una prótesis mioelectrica de brazo por medio de Logica difusa. AOTS and Ricardo Palma University. Retrieved May 22, 2023, from https://www.urp.edu.pe/pdf/id/5798/n/control-una-protesis-mioelectrica-de-brazopor-medio-de-logica-difusaSabalbal, M., Johnson, M., & McAlister, V. (2013). Absence of the genicular arterial anastomosis as generally depicted in textbooks. Annals of the Royal College of Surgeons of England, 1–5. https://doi.org/10.1308/003588413X13629960046831instname:Universidad Antonio Nariñoreponame:Repositorio Institucional UANrepourl:https://repositorio.uan.edu.co/The present comprehensive degree work develops a control system focused on the rehabilitation of the knee, the control is reflected in the monitoring of the angular movement. Said angular movement is observed thanks to the active orthosis designed and simulated in a 3D environment, this, with the future objective of creating a capable device in order to automate part of a complete rehabilitation therapy, specifically in passive therapy, which is where the patient needs external help to flex - extend the leg and gradually recover the range of motion. Normally, for any knee injury, a rehabilitation and recovery therapy plan is needed. To give a context of the problem about the lack of automation, we begin by describing a traditional knee rehabilitation therapy, initially the inflammation of the joint is reduced to start as soon as possible with small movements, the position of the patient depends on the professional manager since It can be sitting or lying down, but always looking for the comfort of both to be able to complete the primary exercises that are: Flexion and extension, this happens in passive kinesitherapy. Each time the arc of angular mobility must increase to observe an improvement, the ranges handled by physiotherapists go from 0-20°, 0-40°, 0-60°, 0-90° and the measurement of these angles is carried out by a tool called a goniometer. When inquiring into the rehabilitation process, we find that they do not use this tool and the recovery is subjective, since they depend on the reaction that is reflected in the patient to make decisions, that is, if they feel pain, they stop immediately with therapy until you can continue again. That is why the control system seeks to ensure the angle within the range of 0° to 90° and the movement can be observed in the active orthosis designed in 3D. For the design and development of the Fuzzy control system, the Matlab tool that goes hand in hand with the Simulink platform is used, this programming is done by means of blocks which will have input and output variables, that is why that other external microcontrollers are used for specific actions that will be seen in the development of this document. The active support orthosis is designed in a CAD program called SolidWorks, to then be taken to Simulink where the assembly is carried out in order to unify the entire control system and to be able to proceed with the manipulation. This is demonstrated in the results of the document.El presente trabajo integral de grado desarrolla un sistema de control enfocado en la rehabilitación de la rodilla, el control se ve reflejado en el seguimiento del movimiento angular. Dicho movimiento angular es observado gracias a la ortesis activa diseñada y simulada en un entorno 3D, esto, con el objetivo a futuro de crear un dispositivo capacitado a fin de automatizar parte de una terapia completa de rehabilitación, específicamente en la terapia pasiva, que es donde el paciente necesita de una ayuda externa para realizar la flexión – extensión de la pierna y poco a poco vaya recuperando el arco de movilidad. Normalmente, para cualquier lesión de rodilla se necesita de un plan de terapia de rehabilitación y recuperación. Para dar un contexto del problema acerca de la falta de automatización se comienza describiendo una terapia tradicional de rehabilitación de rodilla. Inicialmente se reduce la inflamación de la articulación para empezar lo más pronto posible con pequeños movimientos. La posición del paciente depende del encargado profesional ya que puede ser sentado o acostado, pero siempre buscando la comodidad de ambos para poder culminar los ejercicios primarios que son: Flexión y extensión. Cada vez el arco de movilidad angular debe ir aumentando para observar una mejora, los rangos manejados por los fisioterapeutas van de 0-30°, 0-60°, 0-90° y la medición de estos ángulos es realizada por una herramienta llamada goniómetro. Al indagar en el proceso de rehabilitación, se encuentra que no hacen uso de dicha herramienta y la recuperación es subjetiva, ya que, dependen de la reacción que se refleja en el paciente para tomar decisiones, es decir, si siente dolor, se para inmediatamente con la terapia hasta que pueda continuar otra vez. Es por eso que se busca mediante el sistema de control asegurar el ángulo dentro del rango de 0° a 90° y se pueda observar el movimiento en la ortesis activa diseñada en 3D. Para el diseño y desarrollo del sistema de control Fuzzy, se hace uso de la herramienta Matlab que va de la mano con la plataforma Simulink. La programación se lleva a cabo utilizando bloques que contienen variables de entrada y salida. Sin embargo, para realizar acciones específicas que se describen en este documento, se emplean microcontroladores externos adicionales. La ortesis activa de apoyo se diseña en un programa CAD llamado SolidWorks, para luego ser llevado a Simulink en donde se realizar el ensamblado con el fin de unificar todo el sistema de control y poder proceder a la manipulación. Lo anterior se ve demostrado en los resultados del documento.Ingeniero(a) Biomédico(a)PregradoPresencialProyectospaUniversidad Antonio NariñoIngeniería BiomédicaFacultad de Ingeniería Mecánica, Electrónica y BiomédicaPopayán - Alto CaucaRehabilitación de rodillaControl FuzzyOrtesis 3D56.23 V761dKnee rehabilitationFuzzy Control3D OrthosisDiseño de un sistema de control Fuzzy para el manejo de una ortesis de la rodilla activa simula en un entorno 3DTrabajo de grado (Pregrado y/o Especialización)http://purl.org/coar/resource_type/c_7a1fhttp://purl.org/coar/version/c_970fb48d4fbd8a85GeneralORIGINAL2023_HaroldVillota2023_HaroldVillotaDocumento TIGapplication/pdf2783027https://repositorio.uan.edu.co/bitstreams/22a5400a-9bdf-455c-8f2e-ec1fdf6db5b4/download0ccf19ae350bcdc643c7c257cf794fa0MD512023_HaroldVillota_Acta2023_HaroldVillota_ActaACTA DE EVALUACION DE TRABAJO DE GRADOapplication/pdf165483https://repositorio.uan.edu.co/bitstreams/fab2985b-bc5b-4bcb-b5da-acc070c04713/download619ac2a3744a5a7bcc82998ea1f81ceeMD522023_HaroldVillota_Autorización2023_HaroldVillota_AutorizaciónAutorización uso de consultaapplication/pdf5399593https://repositorio.uan.edu.co/bitstreams/aec66fb9-6334-4cc0-a6bf-d31109e8bf99/download2d766f62a2c248dd0d0e67ca32ef816cMD542023_HaroldVillota_Turnitin2023_HaroldVillota_TurnitinInforme de similitudapplication/pdf2771738https://repositorio.uan.edu.co/bitstreams/2e249abb-9d71-4266-8456-4d66e75bdfdf/download99733c46a6995ebcf5aee1734c41deddMD53CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8811https://repositorio.uan.edu.co/bitstreams/98378db4-102f-483d-926f-d1059a863679/download9868ccc48a14c8d591352b6eaf7f6239MD55123456789/8405oai:repositorio.uan.edu.co:123456789/84052024-10-09 22:54:08.328https://creativecommons.org/licenses/by-nc-nd/4.0/Acceso abiertoopen.accesshttps://repositorio.uan.edu.coRepositorio Institucional UANalertas.repositorio@uan.edu.co