Analysis of the influence of thickness on fire reaction performance in polyisocyanurate core sandwich panels
Sandwich panels (also known as insulated panels) have been traditionally used for industrial buildings and warehouses, but nowadays are being increasingly a favorable choice in building construction, mainly in wall cladding and roofing systems. This paper presents the results of an experimental and...
- Autores:
-
Murillo, Michel
Tutikian, Bernardo
Christ, Roberto
Silva Oliveira, Luis Felipe
Maschen, Makeli
Gómez Plata, leandro
Silva Oliveira, Marcos Leandro
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2020
- Institución:
- Corporación Universidad de la Costa
- Repositorio:
- REDICUC - Repositorio CUC
- Idioma:
- eng
- OAI Identifier:
- oai:repositorio.cuc.edu.co:11323/6749
- Acceso en línea:
- https://hdl.handle.net/11323/6749
https://doi.org/10.1016/j.jmrt.2020.06.088
https://repositorio.cuc.edu.co/
- Palabra clave:
- Analysis of variance
Core sandwich panel
Fire reaction
PIR foam
SBI test
- Rights
- openAccess
- License
- CC0 1.0 Universal