On the use of the p-q theory for harmonic currents cancellation with shunt active filter

Discussion and mathematical proof on necessary and sufficient conditions for the application of the p-q theory for compensating the harmonic currents consumed by non-linear load using a shunt active filter are presented. These conditions over instantaneous active and reactive powers were not address...

Full description

Autores:
Tipo de recurso:
Fecha de publicación:
2019
Institución:
Universidad Tecnológica de Bolívar
Repositorio:
Repositorio Institucional UTB
Idioma:
eng
OAI Identifier:
oai:repositorio.utb.edu.co:20.500.12585/9224
Acceso en línea:
https://hdl.handle.net/20.500.12585/9224
Palabra clave:
Active filter control
Harmonic compensation
P-q theory
Rights
openAccess
License
http://creativecommons.org/licenses/by-nc-nd/4.0/
Description
Summary:Discussion and mathematical proof on necessary and sufficient conditions for the application of the p-q theory for compensating the harmonic currents consumed by non-linear load using a shunt active filter are presented. These conditions over instantaneous active and reactive powers were not addressed before and must be considered on the design of new control strategies based on p-q theory. Theoretical demonstration is proposed and an application example with simulations results is used to validate the theoretical results. © 2019 ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING.