Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system
This article describes the implementation and use of a two-accelerometer system to measure the angle formed between lower joints of weightlifters during the execution of the technical gesture. Being aware of movement between joints will allow identifying bad moves and prevent injuries in athletes. L...
- Autores:
- Tipo de recurso:
- Fecha de publicación:
- 2014
- Institución:
- Universidad Tecnológica de Bolívar
- Repositorio:
- Repositorio Institucional UTB
- Idioma:
- eng
- OAI Identifier:
- oai:repositorio.utb.edu.co:20.500.12585/9044
- Acceso en línea:
- https://hdl.handle.net/20.500.12585/9044
- Palabra clave:
- Mechatronics
Hardware and software
Open platforms
Accelerometers
- Rights
- restrictedAccess
- License
- http://creativecommons.org/licenses/by-nc-nd/4.0/
id |
UTB2_1163464d2286a238412bb96630bd525f |
---|---|
oai_identifier_str |
oai:repositorio.utb.edu.co:20.500.12585/9044 |
network_acronym_str |
UTB2 |
network_name_str |
Repositorio Institucional UTB |
repository_id_str |
|
spelling |
Marrugo A.G.Diaz Parada R.A.Martínez-Santos, Juan Carlos2020-03-26T16:32:50Z2020-03-26T16:32:50Z20142014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014 - Conference Proceedings9781479979325https://hdl.handle.net/20.500.12585/904410.1109/CIIMA.2014.6983443Universidad Tecnológica de BolívarRepositorio UTB5668287670026325154200This article describes the implementation and use of a two-accelerometer system to measure the angle formed between lower joints of weightlifters during the execution of the technical gesture. Being aware of movement between joints will allow identifying bad moves and prevent injuries in athletes. Likewise, it will help in turn to rehabilitation for people with problems in the movement of their joints. This design is based on open platforms both hardware and software. The preliminary result shows that we can connect a two-accelerometer system with an error in the measure of the angle no greater than 1.3% (0.795% on average). © 2014 IEEE.Universidad Tecnologica de BolivarRecurso electrónicoapplication/pdfengInstitute of Electrical and Electronics Engineers Inc.http://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/restrictedAccessAtribución-NoComercial 4.0 Internacionalhttp://purl.org/coar/access_right/c_16echttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84930989293&doi=10.1109%2fCIIMA.2014.6983443&partnerID=40&md5=a4e736290f03b6e43df922fd4d025cd6Scopus2-s2.0-849309892932014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014Study of the lower limp's angle during weightlifting exercises using an accelerometer-based systeminfo:eu-repo/semantics/conferenceObjectinfo:eu-repo/semantics/publishedVersionConferenciahttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_c94fMechatronicsHardware and softwareOpen platformsAccelerometers22 October 2014 through 24 October 2014Instituto Distrital de Recreación y Deporte, , http://ider.gov.co/Mayagoitia, R.E., Nene, A.V., Veltink, P.H., Accelerometer and rate gyroscope measurement of kinematics: An inexpensive alternative to optical motion analysis systems (2002) Journal of Biomechanics, 35 (4), pp. 537-542Cheng, P., Oelmann, B., Joint-angle measurement using accelerometers and gyroscopes?a survey (2010) Instrumentation and Measurement, IEEE Transactions on, 59 (2), pp. 404-414Fry, B., Reas, C., (2014) Processing Library for Visual Arts and Design, , http://www.processing.org, AugXiao-Mao, G., Bao-Sheng, Z., Fan, Z., Yu-Jie, Y., Wei, Z., Xi, L., Optimal design model for crank-connecting rod mechanism of atype stirling engine (2011) Consumer Electronics, Communications and Networks (CECNet), 2011 International Conference On. IEEE, pp. 519-522Veltink, P.H., Franken, H.M., Detection of knee unlock during stance by accelerometry (1996) Rehabilitation Engineering, IEEE Transactions on, 4 (4), pp. 395-402Dong, W., Chen, I., Lim, K., Goh, Y., (2007) Measuring Uniaxial Joint Angles with A Minimal Accelerometer Configuration, pp. 88-91Dejnabadi, H., Jolles, B.M., Aminian, K., A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes (2005) Biomedical Engineering, IEEE Transactions on, 52 (8), pp. 1478-1484(2008) Producto Punto, , http://www.geoan.com/analitica/vectores/productopunto.html(2014) ADXL35 Datasheet and Product Info, , http://www.analog.com/en/mems-sensors/memsinertial-sensors/adxl335/products/product.html, Aughttp://purl.org/coar/resource_type/c_c94fTHUMBNAILMiniProdInv.pngMiniProdInv.pngimage/png23941https://repositorio.utb.edu.co/bitstream/20.500.12585/9044/1/MiniProdInv.png0cb0f101a8d16897fb46fc914d3d7043MD5120.500.12585/9044oai:repositorio.utb.edu.co:20.500.12585/90442023-05-26 16:29:00.228Repositorio Institucional UTBrepositorioutb@utb.edu.co |
dc.title.none.fl_str_mv |
Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system |
title |
Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system |
spellingShingle |
Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system Mechatronics Hardware and software Open platforms Accelerometers |
title_short |
Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system |
title_full |
Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system |
title_fullStr |
Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system |
title_full_unstemmed |
Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system |
title_sort |
Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system |
dc.contributor.editor.none.fl_str_mv |
Marrugo A.G. |
dc.subject.keywords.none.fl_str_mv |
Mechatronics Hardware and software Open platforms Accelerometers |
topic |
Mechatronics Hardware and software Open platforms Accelerometers |
description |
This article describes the implementation and use of a two-accelerometer system to measure the angle formed between lower joints of weightlifters during the execution of the technical gesture. Being aware of movement between joints will allow identifying bad moves and prevent injuries in athletes. Likewise, it will help in turn to rehabilitation for people with problems in the movement of their joints. This design is based on open platforms both hardware and software. The preliminary result shows that we can connect a two-accelerometer system with an error in the measure of the angle no greater than 1.3% (0.795% on average). © 2014 IEEE. |
publishDate |
2014 |
dc.date.issued.none.fl_str_mv |
2014 |
dc.date.accessioned.none.fl_str_mv |
2020-03-26T16:32:50Z |
dc.date.available.none.fl_str_mv |
2020-03-26T16:32:50Z |
dc.type.coarversion.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_c94f |
dc.type.driver.none.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
dc.type.hasversion.none.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.spa.none.fl_str_mv |
Conferencia |
status_str |
publishedVersion |
dc.identifier.citation.none.fl_str_mv |
2014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014 - Conference Proceedings |
dc.identifier.isbn.none.fl_str_mv |
9781479979325 |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12585/9044 |
dc.identifier.doi.none.fl_str_mv |
10.1109/CIIMA.2014.6983443 |
dc.identifier.instname.none.fl_str_mv |
Universidad Tecnológica de Bolívar |
dc.identifier.reponame.none.fl_str_mv |
Repositorio UTB |
dc.identifier.orcid.none.fl_str_mv |
56682876700 26325154200 |
identifier_str_mv |
2014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014 - Conference Proceedings 9781479979325 10.1109/CIIMA.2014.6983443 Universidad Tecnológica de Bolívar Repositorio UTB 56682876700 26325154200 |
url |
https://hdl.handle.net/20.500.12585/9044 |
dc.language.iso.none.fl_str_mv |
eng |
language |
eng |
dc.relation.conferencedate.none.fl_str_mv |
22 October 2014 through 24 October 2014 |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_16ec |
dc.rights.uri.none.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/4.0/ |
dc.rights.accessrights.none.fl_str_mv |
info:eu-repo/semantics/restrictedAccess |
dc.rights.cc.none.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/4.0/ Atribución-NoComercial 4.0 Internacional http://purl.org/coar/access_right/c_16ec |
eu_rights_str_mv |
restrictedAccess |
dc.format.medium.none.fl_str_mv |
Recurso electrónico |
dc.format.mimetype.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Institute of Electrical and Electronics Engineers Inc. |
publisher.none.fl_str_mv |
Institute of Electrical and Electronics Engineers Inc. |
dc.source.none.fl_str_mv |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84930989293&doi=10.1109%2fCIIMA.2014.6983443&partnerID=40&md5=a4e736290f03b6e43df922fd4d025cd6 Scopus2-s2.0-84930989293 |
institution |
Universidad Tecnológica de Bolívar |
dc.source.event.none.fl_str_mv |
2014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014 |
bitstream.url.fl_str_mv |
https://repositorio.utb.edu.co/bitstream/20.500.12585/9044/1/MiniProdInv.png |
bitstream.checksum.fl_str_mv |
0cb0f101a8d16897fb46fc914d3d7043 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 |
repository.name.fl_str_mv |
Repositorio Institucional UTB |
repository.mail.fl_str_mv |
repositorioutb@utb.edu.co |
_version_ |
1814021619325075456 |