Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system

This article describes the implementation and use of a two-accelerometer system to measure the angle formed between lower joints of weightlifters during the execution of the technical gesture. Being aware of movement between joints will allow identifying bad moves and prevent injuries in athletes. L...

Full description

Autores:
Tipo de recurso:
Fecha de publicación:
2014
Institución:
Universidad Tecnológica de Bolívar
Repositorio:
Repositorio Institucional UTB
Idioma:
eng
OAI Identifier:
oai:repositorio.utb.edu.co:20.500.12585/9044
Acceso en línea:
https://hdl.handle.net/20.500.12585/9044
Palabra clave:
Mechatronics
Hardware and software
Open platforms
Accelerometers
Rights
restrictedAccess
License
http://creativecommons.org/licenses/by-nc-nd/4.0/
id UTB2_1163464d2286a238412bb96630bd525f
oai_identifier_str oai:repositorio.utb.edu.co:20.500.12585/9044
network_acronym_str UTB2
network_name_str Repositorio Institucional UTB
repository_id_str
spelling Marrugo A.G.Diaz Parada R.A.Martínez-Santos, Juan Carlos2020-03-26T16:32:50Z2020-03-26T16:32:50Z20142014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014 - Conference Proceedings9781479979325https://hdl.handle.net/20.500.12585/904410.1109/CIIMA.2014.6983443Universidad Tecnológica de BolívarRepositorio UTB5668287670026325154200This article describes the implementation and use of a two-accelerometer system to measure the angle formed between lower joints of weightlifters during the execution of the technical gesture. Being aware of movement between joints will allow identifying bad moves and prevent injuries in athletes. Likewise, it will help in turn to rehabilitation for people with problems in the movement of their joints. This design is based on open platforms both hardware and software. The preliminary result shows that we can connect a two-accelerometer system with an error in the measure of the angle no greater than 1.3% (0.795% on average). © 2014 IEEE.Universidad Tecnologica de BolivarRecurso electrónicoapplication/pdfengInstitute of Electrical and Electronics Engineers Inc.http://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/restrictedAccessAtribución-NoComercial 4.0 Internacionalhttp://purl.org/coar/access_right/c_16echttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84930989293&doi=10.1109%2fCIIMA.2014.6983443&partnerID=40&md5=a4e736290f03b6e43df922fd4d025cd6Scopus2-s2.0-849309892932014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014Study of the lower limp's angle during weightlifting exercises using an accelerometer-based systeminfo:eu-repo/semantics/conferenceObjectinfo:eu-repo/semantics/publishedVersionConferenciahttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_c94fMechatronicsHardware and softwareOpen platformsAccelerometers22 October 2014 through 24 October 2014Instituto Distrital de Recreación y Deporte, , http://ider.gov.co/Mayagoitia, R.E., Nene, A.V., Veltink, P.H., Accelerometer and rate gyroscope measurement of kinematics: An inexpensive alternative to optical motion analysis systems (2002) Journal of Biomechanics, 35 (4), pp. 537-542Cheng, P., Oelmann, B., Joint-angle measurement using accelerometers and gyroscopes?a survey (2010) Instrumentation and Measurement, IEEE Transactions on, 59 (2), pp. 404-414Fry, B., Reas, C., (2014) Processing Library for Visual Arts and Design, , http://www.processing.org, AugXiao-Mao, G., Bao-Sheng, Z., Fan, Z., Yu-Jie, Y., Wei, Z., Xi, L., Optimal design model for crank-connecting rod mechanism of atype stirling engine (2011) Consumer Electronics, Communications and Networks (CECNet), 2011 International Conference On. IEEE, pp. 519-522Veltink, P.H., Franken, H.M., Detection of knee unlock during stance by accelerometry (1996) Rehabilitation Engineering, IEEE Transactions on, 4 (4), pp. 395-402Dong, W., Chen, I., Lim, K., Goh, Y., (2007) Measuring Uniaxial Joint Angles with A Minimal Accelerometer Configuration, pp. 88-91Dejnabadi, H., Jolles, B.M., Aminian, K., A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes (2005) Biomedical Engineering, IEEE Transactions on, 52 (8), pp. 1478-1484(2008) Producto Punto, , http://www.geoan.com/analitica/vectores/productopunto.html(2014) ADXL35 Datasheet and Product Info, , http://www.analog.com/en/mems-sensors/memsinertial-sensors/adxl335/products/product.html, Aughttp://purl.org/coar/resource_type/c_c94fTHUMBNAILMiniProdInv.pngMiniProdInv.pngimage/png23941https://repositorio.utb.edu.co/bitstream/20.500.12585/9044/1/MiniProdInv.png0cb0f101a8d16897fb46fc914d3d7043MD5120.500.12585/9044oai:repositorio.utb.edu.co:20.500.12585/90442023-05-26 16:29:00.228Repositorio Institucional UTBrepositorioutb@utb.edu.co
dc.title.none.fl_str_mv Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system
title Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system
spellingShingle Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system
Mechatronics
Hardware and software
Open platforms
Accelerometers
title_short Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system
title_full Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system
title_fullStr Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system
title_full_unstemmed Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system
title_sort Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system
dc.contributor.editor.none.fl_str_mv Marrugo A.G.
dc.subject.keywords.none.fl_str_mv Mechatronics
Hardware and software
Open platforms
Accelerometers
topic Mechatronics
Hardware and software
Open platforms
Accelerometers
description This article describes the implementation and use of a two-accelerometer system to measure the angle formed between lower joints of weightlifters during the execution of the technical gesture. Being aware of movement between joints will allow identifying bad moves and prevent injuries in athletes. Likewise, it will help in turn to rehabilitation for people with problems in the movement of their joints. This design is based on open platforms both hardware and software. The preliminary result shows that we can connect a two-accelerometer system with an error in the measure of the angle no greater than 1.3% (0.795% on average). © 2014 IEEE.
publishDate 2014
dc.date.issued.none.fl_str_mv 2014
dc.date.accessioned.none.fl_str_mv 2020-03-26T16:32:50Z
dc.date.available.none.fl_str_mv 2020-03-26T16:32:50Z
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_c94f
dc.type.driver.none.fl_str_mv info:eu-repo/semantics/conferenceObject
dc.type.hasversion.none.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.spa.none.fl_str_mv Conferencia
status_str publishedVersion
dc.identifier.citation.none.fl_str_mv 2014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014 - Conference Proceedings
dc.identifier.isbn.none.fl_str_mv 9781479979325
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12585/9044
dc.identifier.doi.none.fl_str_mv 10.1109/CIIMA.2014.6983443
dc.identifier.instname.none.fl_str_mv Universidad Tecnológica de Bolívar
dc.identifier.reponame.none.fl_str_mv Repositorio UTB
dc.identifier.orcid.none.fl_str_mv 56682876700
26325154200
identifier_str_mv 2014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014 - Conference Proceedings
9781479979325
10.1109/CIIMA.2014.6983443
Universidad Tecnológica de Bolívar
Repositorio UTB
56682876700
26325154200
url https://hdl.handle.net/20.500.12585/9044
dc.language.iso.none.fl_str_mv eng
language eng
dc.relation.conferencedate.none.fl_str_mv 22 October 2014 through 24 October 2014
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_16ec
dc.rights.uri.none.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights.accessrights.none.fl_str_mv info:eu-repo/semantics/restrictedAccess
dc.rights.cc.none.fl_str_mv Atribución-NoComercial 4.0 Internacional
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
Atribución-NoComercial 4.0 Internacional
http://purl.org/coar/access_right/c_16ec
eu_rights_str_mv restrictedAccess
dc.format.medium.none.fl_str_mv Recurso electrónico
dc.format.mimetype.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Institute of Electrical and Electronics Engineers Inc.
publisher.none.fl_str_mv Institute of Electrical and Electronics Engineers Inc.
dc.source.none.fl_str_mv https://www.scopus.com/inward/record.uri?eid=2-s2.0-84930989293&doi=10.1109%2fCIIMA.2014.6983443&partnerID=40&md5=a4e736290f03b6e43df922fd4d025cd6
Scopus2-s2.0-84930989293
institution Universidad Tecnológica de Bolívar
dc.source.event.none.fl_str_mv 2014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014
bitstream.url.fl_str_mv https://repositorio.utb.edu.co/bitstream/20.500.12585/9044/1/MiniProdInv.png
bitstream.checksum.fl_str_mv 0cb0f101a8d16897fb46fc914d3d7043
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositorio Institucional UTB
repository.mail.fl_str_mv repositorioutb@utb.edu.co
_version_ 1814021619325075456