Case study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings
The trend of reducing energy consumption and the impact of human activities on nature, has increased significantly in recent years. This trend is also noticeable in civil engineering industry. It has an impact not only on new, but also on restored or adapted buildings. Buildings such as monuments or...
- Autores:
- Tipo de recurso:
- Book
- Fecha de publicación:
- 2019
- Institución:
- Universidad de Bogotá Jorge Tadeo Lozano
- Repositorio:
- Expeditio: repositorio UTadeo
- Idioma:
- eng
- OAI Identifier:
- oai:expeditiorepositorio.utadeo.edu.co:20.500.12010/17490
- Acceso en línea:
- https://content.sciendo.com/view/book/9788395669699/10.2478/9788395669699-034.xml
http://hdl.handle.net/20.500.12010/17490
https://doi.org/10.2478/9788395669699-034 9788395669699
- Palabra clave:
- Arquitectura
Sistemas de aislamiento
Interiores
Edificios históricos
- Rights
- License
- Abierto (Texto Completo)
id |
UTADEO2_f05c0114b0cc29b339c2532f2a0a5544 |
---|---|
oai_identifier_str |
oai:expeditiorepositorio.utadeo.edu.co:20.500.12010/17490 |
network_acronym_str |
UTADEO2 |
network_name_str |
Expeditio: repositorio UTadeo |
repository_id_str |
|
dc.title.spa.fl_str_mv |
Case study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings |
title |
Case study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings |
spellingShingle |
Case study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings Arquitectura Sistemas de aislamiento Interiores Edificios históricos |
title_short |
Case study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings |
title_full |
Case study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings |
title_fullStr |
Case study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings |
title_full_unstemmed |
Case study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings |
title_sort |
Case study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings |
dc.subject.spa.fl_str_mv |
Arquitectura |
topic |
Arquitectura Sistemas de aislamiento Interiores Edificios históricos |
dc.subject.lemb.spa.fl_str_mv |
Sistemas de aislamiento Interiores Edificios históricos |
description |
The trend of reducing energy consumption and the impact of human activities on nature, has increased significantly in recent years. This trend is also noticeable in civil engineering industry. It has an impact not only on new, but also on restored or adapted buildings. Buildings such as monuments or historical buildings are also included in this category. It’s necessary to realize that in case of these types of buildings, there are other values which are more important than technical parameters which should be considered. Mainly it is the social, artistic and craftsmanship value of these buildings. In connection with these types of buildings, the application of interior thermal insulation is usually suggested method to improve thermal parameters of walls and reduce energy consumption. Application of these systems appears to be the most appropriate way to preserve values mentioned above. Modern material research also takes place in this area and brings new developed materials such as capillary active isolation systems. Capillary active insulations solve some of the problems connected with the addition of a thermal insulation on the inner side mentioned in [14]. This paper brings hygro-thermal analysis of four types of mentioned systems applied on massive one-layer masonry made of fireclay bricks, what is most common wall type of historical buildings in Slovakia. These types are thermal insulation plaster, multi-layer system predominantly made of wood-fiber and active layer, calcium silicate system and system made of polyurethane boards with grid of holes filled with capillary active material. |
publishDate |
2019 |
dc.date.created.none.fl_str_mv |
2019 |
dc.date.accessioned.none.fl_str_mv |
2021-02-18T23:12:40Z |
dc.date.available.none.fl_str_mv |
2021-02-18T23:12:40Z |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_2f33 |
format |
http://purl.org/coar/resource_type/c_2f33 |
dc.identifier.other.none.fl_str_mv |
https://content.sciendo.com/view/book/9788395669699/10.2478/9788395669699-034.xml |
dc.identifier.uri.none.fl_str_mv |
http://hdl.handle.net/20.500.12010/17490 |
dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.2478/9788395669699-034 9788395669699 |
url |
https://content.sciendo.com/view/book/9788395669699/10.2478/9788395669699-034.xml http://hdl.handle.net/20.500.12010/17490 https://doi.org/10.2478/9788395669699-034 9788395669699 |
dc.language.iso.spa.fl_str_mv |
eng |
language |
eng |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.local.spa.fl_str_mv |
Abierto (Texto Completo) |
dc.rights.creativecommons.none.fl_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode |
rights_invalid_str_mv |
Abierto (Texto Completo) https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode http://purl.org/coar/access_right/c_abf2 |
dc.format.extent.spa.fl_str_mv |
9 páginas |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Sciendo |
institution |
Universidad de Bogotá Jorge Tadeo Lozano |
bitstream.url.fl_str_mv |
https://expeditiorepositorio.utadeo.edu.co/bitstream/20.500.12010/17490/3/Case%20study%20of%20application%20of%20capillary%20active%20thermal%20insulation%20systems%20used%20as%20an%20interior%20insulation%20for%20historical%20buildings_50.pdf.jpg https://expeditiorepositorio.utadeo.edu.co/bitstream/20.500.12010/17490/2/license.txt https://expeditiorepositorio.utadeo.edu.co/bitstream/20.500.12010/17490/1/Case%20study%20of%20application%20of%20capillary%20active%20thermal%20insulation%20systems%20used%20as%20an%20interior%20insulation%20for%20historical%20buildings_50.pdf |
bitstream.checksum.fl_str_mv |
a9ea621765425a55e3e30552a6c4c9d7 abceeb1c943c50d3343516f9dbfc110f 6744791b772a176348d22244cbbfb258 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional - Universidad Jorge Tadeo Lozano |
repository.mail.fl_str_mv |
expeditio@utadeo.edu.co |
_version_ |
1818152671894306816 |
spelling |
2021-02-18T23:12:40Z2021-02-18T23:12:40Z2019https://content.sciendo.com/view/book/9788395669699/10.2478/9788395669699-034.xmlhttp://hdl.handle.net/20.500.12010/17490https://doi.org/10.2478/9788395669699-034 97883956696999 páginasapplication/pdfengSciendoArquitecturaSistemas de aislamientoInterioresEdificios históricosCase study of application of capillary active thermal insulation systems used as an interior insulation for historical buildingsAbierto (Texto Completo)https://creativecommons.org/licenses/by-nc-nd/4.0/legalcodehttp://purl.org/coar/access_right/c_abf2The trend of reducing energy consumption and the impact of human activities on nature, has increased significantly in recent years. This trend is also noticeable in civil engineering industry. It has an impact not only on new, but also on restored or adapted buildings. Buildings such as monuments or historical buildings are also included in this category. It’s necessary to realize that in case of these types of buildings, there are other values which are more important than technical parameters which should be considered. Mainly it is the social, artistic and craftsmanship value of these buildings. In connection with these types of buildings, the application of interior thermal insulation is usually suggested method to improve thermal parameters of walls and reduce energy consumption. Application of these systems appears to be the most appropriate way to preserve values mentioned above. Modern material research also takes place in this area and brings new developed materials such as capillary active isolation systems. Capillary active insulations solve some of the problems connected with the addition of a thermal insulation on the inner side mentioned in [14]. This paper brings hygro-thermal analysis of four types of mentioned systems applied on massive one-layer masonry made of fireclay bricks, what is most common wall type of historical buildings in Slovakia. These types are thermal insulation plaster, multi-layer system predominantly made of wood-fiber and active layer, calcium silicate system and system made of polyurethane boards with grid of holes filled with capillary active material.http://purl.org/coar/resource_type/c_2f33Vacek, ŠimonKostelník, RadovanTHUMBNAILCase study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings_50.pdf.jpgCase study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings_50.pdf.jpgIM Thumbnailimage/jpeg16267https://expeditiorepositorio.utadeo.edu.co/bitstream/20.500.12010/17490/3/Case%20study%20of%20application%20of%20capillary%20active%20thermal%20insulation%20systems%20used%20as%20an%20interior%20insulation%20for%20historical%20buildings_50.pdf.jpga9ea621765425a55e3e30552a6c4c9d7MD53open accessLICENSElicense.txtlicense.txttext/plain; charset=utf-82938https://expeditiorepositorio.utadeo.edu.co/bitstream/20.500.12010/17490/2/license.txtabceeb1c943c50d3343516f9dbfc110fMD52open accessORIGINALCase study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings_50.pdfCase study of application of capillary active thermal insulation systems used as an interior insulation for historical buildings_50.pdfVer documentoapplication/pdf2844048https://expeditiorepositorio.utadeo.edu.co/bitstream/20.500.12010/17490/1/Case%20study%20of%20application%20of%20capillary%20active%20thermal%20insulation%20systems%20used%20as%20an%20interior%20insulation%20for%20historical%20buildings_50.pdf6744791b772a176348d22244cbbfb258MD51open access20.500.12010/17490oai:expeditiorepositorio.utadeo.edu.co:20.500.12010/174902021-02-19 16:11:25.445open accessRepositorio Institucional - Universidad Jorge Tadeo Lozanoexpeditio@utadeo.edu.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 |