Design and fabrication of an electrochemical sensor for the measurement of adherent cells' viability

Single-cell measurements have appeared in the need to obtain real time viability information with a high resolution. The following thesis aims to design and fabricate a lab-on-a-chip device that allows the detection of adherent cells viability via electrical impedance sprectroscopy (EIS). The device...

Full description

Autores:
López Barbosa, Natalia
Tipo de recurso:
Trabajo de grado de pregrado
Fecha de publicación:
2017
Institución:
Universidad de los Andes
Repositorio:
Séneca: repositorio Uniandes
Idioma:
eng
OAI Identifier:
oai:repositorio.uniandes.edu.co:1992/39739
Acceso en línea:
http://hdl.handle.net/1992/39739
Palabra clave:
Espectroscopia de impedancia
Cultivo de células
Células vero
Ingeniería
Rights
openAccess
License
https://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdf
id UNIANDES2_e36fe49e42939bd2080bfa1be8f209d7
oai_identifier_str oai:repositorio.uniandes.edu.co:1992/39739
network_acronym_str UNIANDES2
network_name_str Séneca: repositorio Uniandes
repository_id_str
spelling Al consultar y hacer uso de este recurso, está aceptando las condiciones de uso establecidas por los autores.https://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdfinfo:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Osma Cruz, Johann Faccelovirtual::10019-1López Barbosa, Natalia3b44614a-567d-4213-aa08-f217680498fc500Salazar Gómez, Antonio José2020-06-10T16:29:40Z2020-06-10T16:29:40Z2017http://hdl.handle.net/1992/39739u807122.pdfinstname:Universidad de los Andesreponame:Repositorio Institucional Sénecarepourl:https://repositorio.uniandes.edu.co/Single-cell measurements have appeared in the need to obtain real time viability information with a high resolution. The following thesis aims to design and fabricate a lab-on-a-chip device that allows the detection of adherent cells viability via electrical impedance sprectroscopy (EIS). The device is tested with Vero cells at different culture times and compared with traditional MTT viability assay. Two equivalent circuits have been found to describe the behavior of the device with and without the cell culture. The studied device gives and insight of the possibilities of electrochemical measurements in single-cell experiments"Las mediciones de una sola célula han aparecido como consecuencia de la necesidad de obtener información de viabilidad celular en tiempo real y con una alta resolución. La siguiente tesis busca diseñar y fabricar un dispositivo de tipo lab-on-a-chip que permita la detección de la viabilidad celular de líneas adherentes a través de la medición de espectroscopía de impedancias (EIS por sus siglas en inglés). El dispositivo fue probado con células Vero a diferentes tiempos de cultivo y comparado con un ensayo tradicional de viabilidad de MTT. Dos circuitos equivalentes fueron encontrados para describir el comportamiento del dispositivo con y sin el cultivo celular. El dispositivo permite observar las posibilidades de utilizar mediciones electroquímicas en experimentos de una única célula."--Tomado del Formato de Documento de GradoIngeniero ElectrónicoPregrado38 hojasapplication/pdfengUniandesIngeniería ElectrónicaFacultad de IngenieríaDepartamento de Ingeniería Eléctrica y Electrónicainstname:Universidad de los Andesreponame:Repositorio Institucional SénecaDesign and fabrication of an electrochemical sensor for the measurement of adherent cells' viabilityTrabajo de grado - Pregradoinfo:eu-repo/semantics/bachelorThesishttp://purl.org/coar/resource_type/c_7a1fhttp://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/TPEspectroscopia de impedanciaCultivo de célulasCélulas veroIngenieríaPublicationhttps://scholar.google.es/citations?user=6QQ-dqMAAAAJvirtual::10019-10000-0003-2928-3406virtual::10019-1https://scienti.minciencias.gov.co/cvlac/visualizador/generarCurriculoCv.do?cod_rh=0000221112virtual::10019-1a9f6ef37-65d7-4484-be71-8f3b4067a8favirtual::10019-1a9f6ef37-65d7-4484-be71-8f3b4067a8favirtual::10019-1TEXTu807122.pdf.txtu807122.pdf.txtExtracted texttext/plain32065https://repositorio.uniandes.edu.co/bitstreams/23b1bc16-88c7-457f-a19c-aa03e34cc990/download6dd4ae6038d8f3b9069c768da1a0a0ceMD54THUMBNAILu807122.pdf.jpgu807122.pdf.jpgIM Thumbnailimage/jpeg11373https://repositorio.uniandes.edu.co/bitstreams/48e33272-cf30-4d3a-8cb4-7d8077ecfd25/download3b9533169c09a4198fd70d819f5c7fecMD55ORIGINALu807122.pdfapplication/pdf752674https://repositorio.uniandes.edu.co/bitstreams/c1f36f8f-eea9-4331-ac0b-b09426b54cd3/download8f7a70948ef27896a92fca5b4f141474MD511992/39739oai:repositorio.uniandes.edu.co:1992/397392024-03-13 14:04:51.581https://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdfopen.accesshttps://repositorio.uniandes.edu.coRepositorio institucional Sénecaadminrepositorio@uniandes.edu.co
dc.title.es_CO.fl_str_mv Design and fabrication of an electrochemical sensor for the measurement of adherent cells' viability
title Design and fabrication of an electrochemical sensor for the measurement of adherent cells' viability
spellingShingle Design and fabrication of an electrochemical sensor for the measurement of adherent cells' viability
Espectroscopia de impedancia
Cultivo de células
Células vero
Ingeniería
title_short Design and fabrication of an electrochemical sensor for the measurement of adherent cells' viability
title_full Design and fabrication of an electrochemical sensor for the measurement of adherent cells' viability
title_fullStr Design and fabrication of an electrochemical sensor for the measurement of adherent cells' viability
title_full_unstemmed Design and fabrication of an electrochemical sensor for the measurement of adherent cells' viability
title_sort Design and fabrication of an electrochemical sensor for the measurement of adherent cells' viability
dc.creator.fl_str_mv López Barbosa, Natalia
dc.contributor.advisor.none.fl_str_mv Osma Cruz, Johann Faccelo
dc.contributor.author.none.fl_str_mv López Barbosa, Natalia
dc.contributor.jury.none.fl_str_mv Salazar Gómez, Antonio José
dc.subject.keyword.es_CO.fl_str_mv Espectroscopia de impedancia
Cultivo de células
Células vero
topic Espectroscopia de impedancia
Cultivo de células
Células vero
Ingeniería
dc.subject.themes.none.fl_str_mv Ingeniería
description Single-cell measurements have appeared in the need to obtain real time viability information with a high resolution. The following thesis aims to design and fabricate a lab-on-a-chip device that allows the detection of adherent cells viability via electrical impedance sprectroscopy (EIS). The device is tested with Vero cells at different culture times and compared with traditional MTT viability assay. Two equivalent circuits have been found to describe the behavior of the device with and without the cell culture. The studied device gives and insight of the possibilities of electrochemical measurements in single-cell experiments
publishDate 2017
dc.date.issued.none.fl_str_mv 2017
dc.date.accessioned.none.fl_str_mv 2020-06-10T16:29:40Z
dc.date.available.none.fl_str_mv 2020-06-10T16:29:40Z
dc.type.spa.fl_str_mv Trabajo de grado - Pregrado
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/bachelorThesis
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_7a1f
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/TP
format http://purl.org/coar/resource_type/c_7a1f
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/1992/39739
dc.identifier.pdf.none.fl_str_mv u807122.pdf
dc.identifier.instname.spa.fl_str_mv instname:Universidad de los Andes
dc.identifier.reponame.spa.fl_str_mv reponame:Repositorio Institucional Séneca
dc.identifier.repourl.spa.fl_str_mv repourl:https://repositorio.uniandes.edu.co/
url http://hdl.handle.net/1992/39739
identifier_str_mv u807122.pdf
instname:Universidad de los Andes
reponame:Repositorio Institucional Séneca
repourl:https://repositorio.uniandes.edu.co/
dc.language.iso.es_CO.fl_str_mv eng
language eng
dc.rights.uri.*.fl_str_mv https://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdf
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv https://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdf
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.extent.es_CO.fl_str_mv 38 hojas
dc.format.mimetype.es_CO.fl_str_mv application/pdf
dc.publisher.es_CO.fl_str_mv Uniandes
dc.publisher.program.es_CO.fl_str_mv Ingeniería Electrónica
dc.publisher.faculty.es_CO.fl_str_mv Facultad de Ingeniería
dc.publisher.department.es_CO.fl_str_mv Departamento de Ingeniería Eléctrica y Electrónica
dc.source.es_CO.fl_str_mv instname:Universidad de los Andes
reponame:Repositorio Institucional Séneca
instname_str Universidad de los Andes
institution Universidad de los Andes
reponame_str Repositorio Institucional Séneca
collection Repositorio Institucional Séneca
bitstream.url.fl_str_mv https://repositorio.uniandes.edu.co/bitstreams/23b1bc16-88c7-457f-a19c-aa03e34cc990/download
https://repositorio.uniandes.edu.co/bitstreams/48e33272-cf30-4d3a-8cb4-7d8077ecfd25/download
https://repositorio.uniandes.edu.co/bitstreams/c1f36f8f-eea9-4331-ac0b-b09426b54cd3/download
bitstream.checksum.fl_str_mv 6dd4ae6038d8f3b9069c768da1a0a0ce
3b9533169c09a4198fd70d819f5c7fec
8f7a70948ef27896a92fca5b4f141474
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio institucional Séneca
repository.mail.fl_str_mv adminrepositorio@uniandes.edu.co
_version_ 1812133957197627392