Development and implementation of a wearable system with ear-EEG for the monitoring of epileptic seizures

The diagnosis of Epileptic seizures is made by electroencephalograph equipment in a clinical environment. The problems of these equipment are the short recording time (20 to 30 minutes) and the different conditions between a clinical environment and an external environment. This paper presents a sol...

Full description

Autores:
Juez Suárez, José Yesith
Tipo de recurso:
Fecha de publicación:
2020
Institución:
Universidad de los Andes
Repositorio:
Séneca: repositorio Uniandes
Idioma:
eng
OAI Identifier:
oai:repositorio.uniandes.edu.co:1992/48660
Acceso en línea:
http://hdl.handle.net/1992/48660
Palabra clave:
Procesamiento de señales
Epilepsia
Electroencefalografía
Aplicaciones móviles
Ingeniería
Rights
openAccess
License
http://creativecommons.org/licenses/by-nc-nd/4.0/
id UNIANDES2_9ccf7db4907b09ba395df7037937c105
oai_identifier_str oai:repositorio.uniandes.edu.co:1992/48660
network_acronym_str UNIANDES2
network_name_str Séneca: repositorio Uniandes
repository_id_str
spelling Al consultar y hacer uso de este recurso, está aceptando las condiciones de uso establecidas por los autores.http://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Valderrama Manrique, Mario Andrésvirtual::13167-1Juez Suárez, José Yesith149d5e67-e1e5-4e8c-9ef8-048a3787deb9600Gómez Martínez, RodrigoSegura Quijano, Fredy EnriqueUnigarro Calpa, Edgar Alberto2021-02-18T12:25:46Z2021-02-18T12:25:46Z2020http://hdl.handle.net/1992/48660u833306.pdfinstname:Universidad de los Andesreponame:Repositorio Institucional Sénecarepourl:https://repositorio.uniandes.edu.co/The diagnosis of Epileptic seizures is made by electroencephalograph equipment in a clinical environment. The problems of these equipment are the short recording time (20 to 30 minutes) and the different conditions between a clinical environment and an external environment. This paper presents a solution of these problems with the development of a wearable system with ear-EEG for the monitoring of epileptic seizures, that allows a longer time for continue monitoring of EEG signals and the tests can realize in an ambulatory environmentEl diagnóstico de crisis de epilepsia es realizado por un equipo de electroencefalografía en un ambiente clínico. Los problemas de este equipo son el corto periodo de registro (entre 20 a 30 minutos) y las diferentes condiciones que hay entre un ambiente clínico y un ambiente externo. Este artículo presenta una solución de estos problemas con el desarrollo de un sistema vestible con electrodos ear-EEG para el monitoreo de crisis de epilepsia, permitiendo un monitoreo continuo con larga duración de señales de EEG. Adicionalmente, las pruebas se realizan en un ambiente ambulatorio.Magíster en Ingeniería BiomédicaMaestría7 hojasapplication/pdfengUniversidad de los AndesMaestría en Ingeniería BiomédicaFacultad de IngenieríaDepartamento de Ingeniería Biomédicainstname:Universidad de los Andesreponame:Repositorio Institucional SénecaDevelopment and implementation of a wearable system with ear-EEG for the monitoring of epileptic seizuresTrabajo de grado - Maestríainfo:eu-repo/semantics/masterThesishttp://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/TMProcesamiento de señalesEpilepsiaElectroencefalografíaAplicaciones móvilesIngenieríaPublication036bf7e3-a4e3-40cc-b3a3-fa2effe4b3aevirtual::13167-1036bf7e3-a4e3-40cc-b3a3-fa2effe4b3aevirtual::13167-1https://scienti.minciencias.gov.co/cvlac/visualizador/generarCurriculoCv.do?cod_rh=0000344079virtual::13167-1ORIGINALu833306.pdfapplication/pdf842713https://repositorio.uniandes.edu.co/bitstreams/f2baf0da-aa41-4952-97a2-e7eb66d4f65c/downloade0457613fa1690ab18ab5b3dd33584b3MD51TEXTu833306.pdf.txtu833306.pdf.txtExtracted texttext/plain21261https://repositorio.uniandes.edu.co/bitstreams/a8e3283d-f2b7-4925-9f74-6a4fa5cb7c04/download4f0f1476e58c254b4b8435132174f554MD54THUMBNAILu833306.pdf.jpgu833306.pdf.jpgIM Thumbnailimage/jpeg26722https://repositorio.uniandes.edu.co/bitstreams/13885225-4d0f-4c87-a064-f43db98ef39f/downloade3c33a6fb36de92001ea4441b14cd62fMD551992/48660oai:repositorio.uniandes.edu.co:1992/486602024-03-13 14:52:15.972http://creativecommons.org/licenses/by-nc-nd/4.0/open.accesshttps://repositorio.uniandes.edu.coRepositorio institucional Sénecaadminrepositorio@uniandes.edu.co
dc.title.es_CO.fl_str_mv Development and implementation of a wearable system with ear-EEG for the monitoring of epileptic seizures
title Development and implementation of a wearable system with ear-EEG for the monitoring of epileptic seizures
spellingShingle Development and implementation of a wearable system with ear-EEG for the monitoring of epileptic seizures
Procesamiento de señales
Epilepsia
Electroencefalografía
Aplicaciones móviles
Ingeniería
title_short Development and implementation of a wearable system with ear-EEG for the monitoring of epileptic seizures
title_full Development and implementation of a wearable system with ear-EEG for the monitoring of epileptic seizures
title_fullStr Development and implementation of a wearable system with ear-EEG for the monitoring of epileptic seizures
title_full_unstemmed Development and implementation of a wearable system with ear-EEG for the monitoring of epileptic seizures
title_sort Development and implementation of a wearable system with ear-EEG for the monitoring of epileptic seizures
dc.creator.fl_str_mv Juez Suárez, José Yesith
dc.contributor.advisor.none.fl_str_mv Valderrama Manrique, Mario Andrés
dc.contributor.author.none.fl_str_mv Juez Suárez, José Yesith
dc.contributor.jury.none.fl_str_mv Gómez Martínez, Rodrigo
Segura Quijano, Fredy Enrique
Unigarro Calpa, Edgar Alberto
dc.subject.armarc.es_CO.fl_str_mv Procesamiento de señales
Epilepsia
Electroencefalografía
Aplicaciones móviles
topic Procesamiento de señales
Epilepsia
Electroencefalografía
Aplicaciones móviles
Ingeniería
dc.subject.themes.none.fl_str_mv Ingeniería
description The diagnosis of Epileptic seizures is made by electroencephalograph equipment in a clinical environment. The problems of these equipment are the short recording time (20 to 30 minutes) and the different conditions between a clinical environment and an external environment. This paper presents a solution of these problems with the development of a wearable system with ear-EEG for the monitoring of epileptic seizures, that allows a longer time for continue monitoring of EEG signals and the tests can realize in an ambulatory environment
publishDate 2020
dc.date.issued.es_CO.fl_str_mv 2020
dc.date.accessioned.none.fl_str_mv 2021-02-18T12:25:46Z
dc.date.available.none.fl_str_mv 2021-02-18T12:25:46Z
dc.type.spa.fl_str_mv Trabajo de grado - Maestría
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/masterThesis
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/TM
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/1992/48660
dc.identifier.pdf.none.fl_str_mv u833306.pdf
dc.identifier.instname.spa.fl_str_mv instname:Universidad de los Andes
dc.identifier.reponame.spa.fl_str_mv reponame:Repositorio Institucional Séneca
dc.identifier.repourl.spa.fl_str_mv repourl:https://repositorio.uniandes.edu.co/
url http://hdl.handle.net/1992/48660
identifier_str_mv u833306.pdf
instname:Universidad de los Andes
reponame:Repositorio Institucional Séneca
repourl:https://repositorio.uniandes.edu.co/
dc.language.iso.es_CO.fl_str_mv eng
language eng
dc.rights.uri.*.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.extent.es_CO.fl_str_mv 7 hojas
dc.format.mimetype.es_CO.fl_str_mv application/pdf
dc.publisher.es_CO.fl_str_mv Universidad de los Andes
dc.publisher.program.es_CO.fl_str_mv Maestría en Ingeniería Biomédica
dc.publisher.faculty.es_CO.fl_str_mv Facultad de Ingeniería
dc.publisher.department.es_CO.fl_str_mv Departamento de Ingeniería Biomédica
dc.source.es_CO.fl_str_mv instname:Universidad de los Andes
reponame:Repositorio Institucional Séneca
instname_str Universidad de los Andes
institution Universidad de los Andes
reponame_str Repositorio Institucional Séneca
collection Repositorio Institucional Séneca
bitstream.url.fl_str_mv https://repositorio.uniandes.edu.co/bitstreams/f2baf0da-aa41-4952-97a2-e7eb66d4f65c/download
https://repositorio.uniandes.edu.co/bitstreams/a8e3283d-f2b7-4925-9f74-6a4fa5cb7c04/download
https://repositorio.uniandes.edu.co/bitstreams/13885225-4d0f-4c87-a064-f43db98ef39f/download
bitstream.checksum.fl_str_mv e0457613fa1690ab18ab5b3dd33584b3
4f0f1476e58c254b4b8435132174f554
e3c33a6fb36de92001ea4441b14cd62f
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio institucional Séneca
repository.mail.fl_str_mv adminrepositorio@uniandes.edu.co
_version_ 1812134008652300288