Economic optimization of insulation and grounding in AC transmission line exposed to direct lightning strokes
"In this document, De Oliveira/Hileman economic optimization model was applied in the same EPRI's 345kV HVAC line using four different BFR techniques such as EPRI Red Book, IEEE 1247 (Flash program), CIGRE and Montecarlo-ATP. Resulting marginal and total cost curves of the BFR are evaluate...
- Autores:
-
Acevedo Pérez, Ana Leonor
- Tipo de recurso:
- Trabajo de grado de pregrado
- Fecha de publicación:
- 2019
- Institución:
- Universidad de los Andes
- Repositorio:
- Séneca: repositorio Uniandes
- Idioma:
- eng
- OAI Identifier:
- oai:repositorio.uniandes.edu.co:1992/45352
- Acceso en línea:
- http://hdl.handle.net/1992/45352
- Palabra clave:
- Distribución de energía eléctrica
Líneas eléctricas aéreas
Líneas eléctricas
Ingeniería
- Rights
- openAccess
- License
- https://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdf
id |
UNIANDES2_8ad56042b0c4cfd45865db15ae46467a |
---|---|
oai_identifier_str |
oai:repositorio.uniandes.edu.co:1992/45352 |
network_acronym_str |
UNIANDES2 |
network_name_str |
Séneca: repositorio Uniandes |
repository_id_str |
|
spelling |
Al consultar y hacer uso de este recurso, está aceptando las condiciones de uso establecidas por los autores.https://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdfinfo:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Oliveira de Jesus, Paulo Manuel de8779285d-6641-4859-abc5-dadc52816dbb400Acevedo Pérez, Ana Leonorf2dae2ea-c478-4df4-8765-ee133c20eb90500Ríos Mesías, Mario AlbertoTorres Macías, Álvaro2020-09-03T15:57:05Z2020-09-03T15:57:05Z2019http://hdl.handle.net/1992/45352u827376.pdfinstname:Universidad de los Andesreponame:Repositorio Institucional Sénecarepourl:https://repositorio.uniandes.edu.co/"In this document, De Oliveira/Hileman economic optimization model was applied in the same EPRI's 345kV HVAC line using four different BFR techniques such as EPRI Red Book, IEEE 1247 (Flash program), CIGRE and Montecarlo-ATP. Resulting marginal and total cost curves of the BFR are evaluated and compared. Furthermore, the economic method was also applied to a real-world transmission line located in Colombia (Colectora 1 - Cuestecitas - La Loma 500kV). The method allows to determine marginal cost of the BFR either for the EPRI test case (345kV) or the Colombian test case (500kV)."--Tomado del Formato de Documento de Grado."En este documento, el modelo de optimización económica De Oliveira / Hileman [5, 10] se aplicó en la misma línea HVAC de 345 kV de EPRI utilizando cuatro técnicas BFR diferentes, como el Libro Rojo EPRI, IEEE 1247 (programa Flash), CIGRE y Montecarlo-ATP. Las curvas de costo marginal y total resultantes del BFR se evalúan y comparan. Además, el método económico también se aplicó a una línea de transmisión del mundo real ubicada en Colombia (Colectora 1 - Cuestecitas - La Loma 500kV). El método permite determinar el costo marginal del BFR para el caso de prueba EPRI (345 kV) o el caso de prueba colombiano (500 kV)."--Tomado del Formato de Documento de Grado.Ingeniero EléctricoIngeniero ElectrónicoPregrado34 hojasapplication/pdfengUniversidad de los AndesIngeniería EléctricaIngeniería ElectrónicaFacultad de IngenieríaDepartamento de Ingeniería Eléctrica y Electrónicainstname:Universidad de los Andesreponame:Repositorio Institucional SénecaEconomic optimization of insulation and grounding in AC transmission line exposed to direct lightning strokesTrabajo de grado - Pregradoinfo:eu-repo/semantics/bachelorThesishttp://purl.org/coar/resource_type/c_7a1fhttp://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/TPDistribución de energía eléctricaLíneas eléctricas aéreasLíneas eléctricasIngenieríaPublicationTEXTu827376.pdf.txtu827376.pdf.txtExtracted texttext/plain65487https://repositorio.uniandes.edu.co/bitstreams/e420f9ff-a466-4644-a92a-bb5d89fc0ae7/downloadfeeed88fa3c5aec737297cc9a0d2b482MD54ORIGINALu827376.pdfapplication/pdf689835https://repositorio.uniandes.edu.co/bitstreams/ce4921cf-db04-4c7e-837c-606e345e8dfa/download7a720b292bac7c88f943eaa9f0fe3ae4MD51THUMBNAILu827376.pdf.jpgu827376.pdf.jpgIM Thumbnailimage/jpeg9625https://repositorio.uniandes.edu.co/bitstreams/a8c84b9a-d69b-42c1-b9bd-610e732dacfe/download8b40ea9f0c12196780aa01ec40cfbc5cMD551992/45352oai:repositorio.uniandes.edu.co:1992/453522023-10-10 15:17:20.396https://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdfopen.accesshttps://repositorio.uniandes.edu.coRepositorio institucional Sénecaadminrepositorio@uniandes.edu.co |
dc.title.es_CO.fl_str_mv |
Economic optimization of insulation and grounding in AC transmission line exposed to direct lightning strokes |
title |
Economic optimization of insulation and grounding in AC transmission line exposed to direct lightning strokes |
spellingShingle |
Economic optimization of insulation and grounding in AC transmission line exposed to direct lightning strokes Distribución de energía eléctrica Líneas eléctricas aéreas Líneas eléctricas Ingeniería |
title_short |
Economic optimization of insulation and grounding in AC transmission line exposed to direct lightning strokes |
title_full |
Economic optimization of insulation and grounding in AC transmission line exposed to direct lightning strokes |
title_fullStr |
Economic optimization of insulation and grounding in AC transmission line exposed to direct lightning strokes |
title_full_unstemmed |
Economic optimization of insulation and grounding in AC transmission line exposed to direct lightning strokes |
title_sort |
Economic optimization of insulation and grounding in AC transmission line exposed to direct lightning strokes |
dc.creator.fl_str_mv |
Acevedo Pérez, Ana Leonor |
dc.contributor.advisor.none.fl_str_mv |
Oliveira de Jesus, Paulo Manuel de |
dc.contributor.author.none.fl_str_mv |
Acevedo Pérez, Ana Leonor |
dc.contributor.jury.none.fl_str_mv |
Ríos Mesías, Mario Alberto Torres Macías, Álvaro |
dc.subject.armarc.es_CO.fl_str_mv |
Distribución de energía eléctrica Líneas eléctricas aéreas Líneas eléctricas |
topic |
Distribución de energía eléctrica Líneas eléctricas aéreas Líneas eléctricas Ingeniería |
dc.subject.themes.none.fl_str_mv |
Ingeniería |
description |
"In this document, De Oliveira/Hileman economic optimization model was applied in the same EPRI's 345kV HVAC line using four different BFR techniques such as EPRI Red Book, IEEE 1247 (Flash program), CIGRE and Montecarlo-ATP. Resulting marginal and total cost curves of the BFR are evaluated and compared. Furthermore, the economic method was also applied to a real-world transmission line located in Colombia (Colectora 1 - Cuestecitas - La Loma 500kV). The method allows to determine marginal cost of the BFR either for the EPRI test case (345kV) or the Colombian test case (500kV)."--Tomado del Formato de Documento de Grado. |
publishDate |
2019 |
dc.date.issued.none.fl_str_mv |
2019 |
dc.date.accessioned.none.fl_str_mv |
2020-09-03T15:57:05Z |
dc.date.available.none.fl_str_mv |
2020-09-03T15:57:05Z |
dc.type.spa.fl_str_mv |
Trabajo de grado - Pregrado |
dc.type.coarversion.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_7a1f |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/TP |
format |
http://purl.org/coar/resource_type/c_7a1f |
dc.identifier.uri.none.fl_str_mv |
http://hdl.handle.net/1992/45352 |
dc.identifier.pdf.none.fl_str_mv |
u827376.pdf |
dc.identifier.instname.spa.fl_str_mv |
instname:Universidad de los Andes |
dc.identifier.reponame.spa.fl_str_mv |
reponame:Repositorio Institucional Séneca |
dc.identifier.repourl.spa.fl_str_mv |
repourl:https://repositorio.uniandes.edu.co/ |
url |
http://hdl.handle.net/1992/45352 |
identifier_str_mv |
u827376.pdf instname:Universidad de los Andes reponame:Repositorio Institucional Séneca repourl:https://repositorio.uniandes.edu.co/ |
dc.language.iso.es_CO.fl_str_mv |
eng |
language |
eng |
dc.rights.uri.*.fl_str_mv |
https://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdf |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.coar.spa.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
rights_invalid_str_mv |
https://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdf http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.extent.es_CO.fl_str_mv |
34 hojas |
dc.format.mimetype.es_CO.fl_str_mv |
application/pdf |
dc.publisher.es_CO.fl_str_mv |
Universidad de los Andes |
dc.publisher.program.es_CO.fl_str_mv |
Ingeniería Eléctrica Ingeniería Electrónica |
dc.publisher.faculty.es_CO.fl_str_mv |
Facultad de Ingeniería |
dc.publisher.department.es_CO.fl_str_mv |
Departamento de Ingeniería Eléctrica y Electrónica |
dc.source.es_CO.fl_str_mv |
instname:Universidad de los Andes reponame:Repositorio Institucional Séneca |
instname_str |
Universidad de los Andes |
institution |
Universidad de los Andes |
reponame_str |
Repositorio Institucional Séneca |
collection |
Repositorio Institucional Séneca |
bitstream.url.fl_str_mv |
https://repositorio.uniandes.edu.co/bitstreams/e420f9ff-a466-4644-a92a-bb5d89fc0ae7/download https://repositorio.uniandes.edu.co/bitstreams/ce4921cf-db04-4c7e-837c-606e345e8dfa/download https://repositorio.uniandes.edu.co/bitstreams/a8c84b9a-d69b-42c1-b9bd-610e732dacfe/download |
bitstream.checksum.fl_str_mv |
feeed88fa3c5aec737297cc9a0d2b482 7a720b292bac7c88f943eaa9f0fe3ae4 8b40ea9f0c12196780aa01ec40cfbc5c |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio institucional Séneca |
repository.mail.fl_str_mv |
adminrepositorio@uniandes.edu.co |
_version_ |
1812133804536496128 |