Diseño e implementación de un prototipo de simulador solar con lámpara pulsada para la prueba de características eléctricas de paneles fotovoltaicos
ilustraciones, diagramas, figuras, fotografías
- Autores:
-
Nova Rodríguez, David
- Tipo de recurso:
- Fecha de publicación:
- 2023
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/85605
- Palabra clave:
- 620 - Ingeniería y operaciones afines::629 - Otras ramas de la ingeniería
530 - Física::537 - Electricidad y electrónica
Métodos de simulación
Emuladores (Programas de computador)
Simulation methods
Emulators (Computer programs)
Energía solar-Métodos de simulación
Radiación solar
Solar energy - simulation methods
Solar radiation
Emulador solar
Xenón flash
Conversor AC-DC
24 pulsos
Solar emulator
Xenon flash
AC-DC converter
IGBT
24 pulses
Sistema fotovoltaico
Emulador
Photovoltaic system
Emulator
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional
id |
UNACIONAL2_fad2dea68da752fe22d85e8804721d6b |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/85605 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
dc.title.spa.fl_str_mv |
Diseño e implementación de un prototipo de simulador solar con lámpara pulsada para la prueba de características eléctricas de paneles fotovoltaicos |
dc.title.translated.eng.fl_str_mv |
Design and implementation of a prototype solar simulator with pulsed lamp for testing electrical characteristics of photovoltaic panels. |
title |
Diseño e implementación de un prototipo de simulador solar con lámpara pulsada para la prueba de características eléctricas de paneles fotovoltaicos |
spellingShingle |
Diseño e implementación de un prototipo de simulador solar con lámpara pulsada para la prueba de características eléctricas de paneles fotovoltaicos 620 - Ingeniería y operaciones afines::629 - Otras ramas de la ingeniería 530 - Física::537 - Electricidad y electrónica Métodos de simulación Emuladores (Programas de computador) Simulation methods Emulators (Computer programs) Energía solar-Métodos de simulación Radiación solar Solar energy - simulation methods Solar radiation Emulador solar Xenón flash Conversor AC-DC 24 pulsos Solar emulator Xenon flash AC-DC converter IGBT 24 pulses Sistema fotovoltaico Emulador Photovoltaic system Emulator |
title_short |
Diseño e implementación de un prototipo de simulador solar con lámpara pulsada para la prueba de características eléctricas de paneles fotovoltaicos |
title_full |
Diseño e implementación de un prototipo de simulador solar con lámpara pulsada para la prueba de características eléctricas de paneles fotovoltaicos |
title_fullStr |
Diseño e implementación de un prototipo de simulador solar con lámpara pulsada para la prueba de características eléctricas de paneles fotovoltaicos |
title_full_unstemmed |
Diseño e implementación de un prototipo de simulador solar con lámpara pulsada para la prueba de características eléctricas de paneles fotovoltaicos |
title_sort |
Diseño e implementación de un prototipo de simulador solar con lámpara pulsada para la prueba de características eléctricas de paneles fotovoltaicos |
dc.creator.fl_str_mv |
Nova Rodríguez, David |
dc.contributor.advisor.none.fl_str_mv |
Quintero Quintero, Jesús M. |
dc.contributor.author.none.fl_str_mv |
Nova Rodríguez, David |
dc.contributor.researchgroup.spa.fl_str_mv |
LIATER MATISSE |
dc.subject.ddc.spa.fl_str_mv |
620 - Ingeniería y operaciones afines::629 - Otras ramas de la ingeniería 530 - Física::537 - Electricidad y electrónica |
topic |
620 - Ingeniería y operaciones afines::629 - Otras ramas de la ingeniería 530 - Física::537 - Electricidad y electrónica Métodos de simulación Emuladores (Programas de computador) Simulation methods Emulators (Computer programs) Energía solar-Métodos de simulación Radiación solar Solar energy - simulation methods Solar radiation Emulador solar Xenón flash Conversor AC-DC 24 pulsos Solar emulator Xenon flash AC-DC converter IGBT 24 pulses Sistema fotovoltaico Emulador Photovoltaic system Emulator |
dc.subject.lcc.spa.fl_str_mv |
Métodos de simulación Emuladores (Programas de computador) |
dc.subject.lcc.eng.fl_str_mv |
Simulation methods Emulators (Computer programs) |
dc.subject.lemb.spa.fl_str_mv |
Energía solar-Métodos de simulación Radiación solar |
dc.subject.lemb.eng.fl_str_mv |
Solar energy - simulation methods Solar radiation |
dc.subject.proposal.spa.fl_str_mv |
Emulador solar Xenón flash Conversor AC-DC 24 pulsos |
dc.subject.proposal.eng.fl_str_mv |
Solar emulator Xenon flash AC-DC converter IGBT 24 pulses |
dc.subject.wikidata.spa.fl_str_mv |
Sistema fotovoltaico Emulador |
dc.subject.wikidata.eng.fl_str_mv |
Photovoltaic system Emulator |
description |
ilustraciones, diagramas, figuras, fotografías |
publishDate |
2023 |
dc.date.issued.none.fl_str_mv |
2023 |
dc.date.accessioned.none.fl_str_mv |
2024-02-02T17:43:20Z |
dc.date.available.none.fl_str_mv |
2024-02-02T17:43:20Z |
dc.type.spa.fl_str_mv |
Trabajo de grado - Maestría |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/masterThesis |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/acceptedVersion |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/TM |
status_str |
acceptedVersion |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/85605 |
dc.identifier.instname.spa.fl_str_mv |
Universidad Nacional de Colombia |
dc.identifier.reponame.spa.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
dc.identifier.repourl.spa.fl_str_mv |
https://repositorio.unal.edu.co/ |
url |
https://repositorio.unal.edu.co/handle/unal/85605 https://repositorio.unal.edu.co/ |
identifier_str_mv |
Universidad Nacional de Colombia Repositorio Institucional Universidad Nacional de Colombia |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.references.spa.fl_str_mv |
A. Samimi and S. Zarinabadi, “Reduction of Greenhouse gases emission and effect on environment,” J. Am. Sci., vol. 8, no. 8, 2012, [Online]. Available: http://www.americanscience.orghttp//www.americanscience.orgeditor@americanscience.org. N. L. Panwar, S. C. Kaushik, and S. Kothari, “Role of renewable energy sources in environmental protection: A review,” Renew. Sustain. Energy Rev., vol. 15, no. 3, pp. 1513–1524, 2011, doi: 10.1016/j.rser.2010.11.037. D. L. King, W. E. Boyson, and J. A. Kratochvil, “Analysis of factors influencing the annual energy production of photovoltaic systems,” pp. 1356–1361, 2003, doi: 10.1109/pvsc.2002.1190861. C. R. Osterwald, T. W. Cannon, D. R. Myers, T. Glatfelter, W. Czubatyj, and J. Yang, “Methods for Measuring Solar Cell Efficiency,” Sol. Energy, no. c, pp. 623–628, 1985. N. Kishor, M. G. Villalva, S. R. Mohanty, and E. Ruppert, “Modeling of PV module with consideration of environmental factors,” in 2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe), Oct. 2010, pp. 1–5, doi: 10.1109/ISGTEUROPE.2010.5638902. M. Bliss, T. R. Betts, and R. Gottschalg, “Advantages in using LEDs as the main light source in solar simulators for measuring PV device characteristics,” Reliab. Photovolt. Cells, Modul. Components, Syst., vol. 7048, p. 704807, 2008, doi: 10.1117/12.795428. I. 60904-9, International Standard International Standard, vol. 2003. 2003, p. 13 V. Esen, Ş. Sağlam, and B. Oral, “Light sources of solar simulators for photovoltaic devices: A review,” Renew. Sustain. Energy Rev., vol. 77, no. March, pp. 1240–1250, 2017, doi: 10.1016/j.rser.2017.03.062. G. Leary, G. Switzer, G. Kuntz, and T. Kaiser, “Comparison of xenon lamp-based and led-based solar simulators,” 2017 IEEE 44th Photovolt. Spec. Conf. PVSC 2017, pp. 6–9, 2017, doi: 10.1109/PVSC.2017.8366725. R. J. Matson, K. A. Emery, and R. E. Bird, “Terrestrial solar spectra, solar simulation and solar cell short-circuit current calibration: A review,” Sol. Cells, vol. 11, no. 2, pp. 105–145, 1984, doi: 10.1016/0379-6787(84)90022-X. W. Wang and B. Laumert, “Simulate a ‘Sun’ for Solar Research: A Literature Review of Solar Simulator Technology,” pp. 1–37, 2014. J. C. Campo, M. A. Perez, J. M. Mezquita, and J. Sebastian, “Circuit-design criteria for improvement of xenon flash-lamp performance (lamp life, light-pulse, narrowness, uniformity of light intensity in a series of flashes),” pp. 1057–1061, 2002, doi: 10.1109/apec.1997.575780. N. Selvaganesan and S. Lecturer, “A 24-Pulse AC-DC Converter For Improving Power Quality Using Fork Connected Transformer,” no. June, pp. 1–8, 2009. H. D. Division, “Xenon Flash Light IGBT Application Note,” 2014. J. R. Oliver and F. S. Barnes, “A Comparison of Rare-Gas Flashlamps,” IEEE J. Quantum Electron., vol. 5, no. 5, pp. 232–237, 1969, doi: 10.1109/JQE.1969.1075765. J. Fiz, “Study of Single-Mesh LC Flashlamp Driving Circuit for Xenon Flashlamp,” vol. 3, pp. 95–98, 2008. H. Akiyama, M. Kristiansen, H. Krompholz, and B. Maas, “Current-Voltage Characteristics of a High-Current Pulsed Discharge in Air,” IEEE Trans. Plasma Sci., vol. 16, no. 2, pp. 312–316, 1988, doi: 10.1109/27.3830. W. Yao, F. Blaabjerg, X. Zhang, Y. Yang, and Z. Gao, “Zero sequence blocking transformers for multi-pulse rectifier in aerospace applications,” 2014 IEEE Energy Convers. Congr. Expo. ECCE 2014, pp. 999–1006, 2014, doi: 10.1109/ECCE.2014.6953508. D. F. D. Narváez, “Modelado de un convertidor ca/cc trifásico para el análisis de la distorsión armónica .,” p. 82, 2011. Limones Pozos Cesar A and Mendoza Rivera José, “Diseño De Un Rectificador Trifásico Con Convertidor Reductor,” ResearchGate, no. August, 2019. |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial 4.0 Internacional http://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.extent.spa.fl_str_mv |
82 páginas |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.coverage.country.none.fl_str_mv |
Colombia |
dc.publisher.spa.fl_str_mv |
Universidad Nacional de Colombia |
dc.publisher.program.spa.fl_str_mv |
Bogotá - Ingeniería - Maestría en Ingeniería - Ingeniería Eléctrica |
dc.publisher.faculty.spa.fl_str_mv |
Facultad de Ingeniería |
dc.publisher.place.spa.fl_str_mv |
Bogotá, Colombia |
dc.publisher.branch.spa.fl_str_mv |
Universidad Nacional de Colombia - Sede Bogotá |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/85605/1/license.txt https://repositorio.unal.edu.co/bitstream/unal/85605/2/1000467473.2023%20%281%29.pdf https://repositorio.unal.edu.co/bitstream/unal/85605/3/1000467473.2023%20%281%29.pdf.jpg |
bitstream.checksum.fl_str_mv |
eb34b1cf90b7e1103fc9dfd26be24b4a 24cb8488d903853657f1f145cea535d7 da971c5304688b8ba278a07258a901d1 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814089261457080320 |
spelling |
Atribución-NoComercial 4.0 Internacionalhttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Quintero Quintero, Jesús M.38fa10576cee7f699ebd7ef0c55d7686Nova Rodríguez, David4e9f6c6da615eb0a352de7e3c29c1927LIATERMATISSE2024-02-02T17:43:20Z2024-02-02T17:43:20Z2023https://repositorio.unal.edu.co/handle/unal/85605Universidad Nacional de ColombiaRepositorio Institucional Universidad Nacional de Colombiahttps://repositorio.unal.edu.co/ilustraciones, diagramas, figuras, fotografíasPara determinar los parámetros eléctricos de operación de los módulos fotovoltaicos es necesario desarrollar las pruebas en condiciones estándar (1000W/m2, AM 1,5 y 25º C), una de estas condiciones es la irradiancia, la cual se puede obtener de forma natural o artificial, la primera se obtiene de forma directa ante la exposición de los módulos a la radiación solar natural, sin embargo, se tienen algunas limitaciones, dado que depende de las condiciones climáticas de la zona donde se ejecuten las pruebas. Para el desarrollo de una fuente de emisión artificial similar al sol, se consultó la norma IEC 60904-9, donde se especifican los criterios de clasificación de los simuladores en tres criterios, coincidencia espectral, no uniformidad e inestabilidad temporal; estos criterios tienen una estrecha relación con la amplitud uniforme de pulso y su tiempo de duración. Con base en lo anterior, se decide construir un emulador solar con lámpara de Xenón tipo flash, la cual permite obtener un espectro similar al de la luz solar natural, este espectro se garantiza manteniendo los niveles de tensión y densidad de corriente de operación de lámpara. Para cumplir este objetivo, se diseñó, simuló y fabricó un conversor AC – DC, por medio de un transformador de 12 pulsos, una etapa de rectificación, inductancias de acople. Estos equipos en conjunto permiten una tensión de salida entre 300 – 700 VDC, un rizado menor al 3% y un contenido armónico inferior al 5%. Adicionalmente se diseñó e implementó una etapa de control por medio de transistores bipolares de puerta aislada (IGBT), con la capacidad de soportar la corriente, tensión y energía requerida para la emisión de un pulso que cumpla la clasificación de emulador solar en una de las categorías de la norma IEC 60904-9. Los diseños, simulación y pruebas desarrolladas en este trabajo permitirán evaluar la viabilidad y cumplimiento tanto en seguridad como en operación de emulador solar con lámpara de xenón tipo flash e identificar las limitaciones asociadas a la fuente de alimentación de dicho sistema. (Texto tomado de la fuente)To determine the electrical operating parameters of the photovoltaic modules it is necessary to develop tests under standard conditions (1000W/m2, AM 1.5 and 25º C), one of these conditions is the irradiance, which can be obtained naturally or artificially, the first is obtained directly when the modules are exposed to natural solar radiation, however, there are some limitations, since it depends on the climatic conditions of the area where the tests are carried out. For the development of an artificial emission source similar to the sun, the IEC 60904-9 standard was consulted, where the classification criteria of the simulators are specified in three criteria, spectral coincidence, non-uniformity and temporal instability; these criteria are closely related to the uniform pulse amplitude and its duration time. Based on the above, it was decided to build a solar emulator with a flash type Xenon lamp, which allows to obtain a spectrum like that of natural sunlight, this spectrum is guaranteed by maintaining the voltage levels and lamp operation current density. To meet this objective, an AC - DC converter was designed, simulated and manufactured, by means of a 12-pulse transformer, a rectification stage and coupling inductances. Together, this equipment allows an output voltage between 300 - 700 VDC, a ripple of less than 3% and a harmonic content of less than 5%. Additionally, an isolated gate bipolar transistor (IGBT) control stage was designed and implemented, with the capacity to support the current, voltage and energy required for the emission of the pulse for the classification of the solar emulator in one of the categories of the IEC 60904-9 standard. The designs, simulation and tests developed will allow presenting the feasibility and compliance both in safety and operation of the solar emulator with flash type xenon lamp and identify the limitations associated with the backup source.MaestríaMagíster en Ingeniería - Ingeniería EléctricaElectrónica de potencia y metrología82 páginasapplication/pdfspaUniversidad Nacional de ColombiaBogotá - Ingeniería - Maestría en Ingeniería - Ingeniería EléctricaFacultad de IngenieríaBogotá, ColombiaUniversidad Nacional de Colombia - Sede Bogotá620 - Ingeniería y operaciones afines::629 - Otras ramas de la ingeniería530 - Física::537 - Electricidad y electrónicaMétodos de simulaciónEmuladores (Programas de computador)Simulation methodsEmulators (Computer programs)Energía solar-Métodos de simulaciónRadiación solarSolar energy - simulation methodsSolar radiationEmulador solarXenón flashConversor AC-DC24 pulsosSolar emulatorXenon flashAC-DC converterIGBT24 pulsesSistema fotovoltaicoEmuladorPhotovoltaic systemEmulatorDiseño e implementación de un prototipo de simulador solar con lámpara pulsada para la prueba de características eléctricas de paneles fotovoltaicosDesign and implementation of a prototype solar simulator with pulsed lamp for testing electrical characteristics of photovoltaic panels.Trabajo de grado - Maestríainfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/acceptedVersionTexthttp://purl.org/redcol/resource_type/TMColombiaA. Samimi and S. Zarinabadi, “Reduction of Greenhouse gases emission and effect on environment,” J. Am. Sci., vol. 8, no. 8, 2012, [Online]. Available: http://www.americanscience.orghttp//www.americanscience.orgeditor@americanscience.org.N. L. Panwar, S. C. Kaushik, and S. Kothari, “Role of renewable energy sources in environmental protection: A review,” Renew. Sustain. Energy Rev., vol. 15, no. 3, pp. 1513–1524, 2011, doi: 10.1016/j.rser.2010.11.037.D. L. King, W. E. Boyson, and J. A. Kratochvil, “Analysis of factors influencing the annual energy production of photovoltaic systems,” pp. 1356–1361, 2003, doi: 10.1109/pvsc.2002.1190861.C. R. Osterwald, T. W. Cannon, D. R. Myers, T. Glatfelter, W. Czubatyj, and J. Yang, “Methods for Measuring Solar Cell Efficiency,” Sol. Energy, no. c, pp. 623–628, 1985.N. Kishor, M. G. Villalva, S. R. Mohanty, and E. Ruppert, “Modeling of PV module with consideration of environmental factors,” in 2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe), Oct. 2010, pp. 1–5, doi: 10.1109/ISGTEUROPE.2010.5638902.M. Bliss, T. R. Betts, and R. Gottschalg, “Advantages in using LEDs as the main light source in solar simulators for measuring PV device characteristics,” Reliab. Photovolt. Cells, Modul. Components, Syst., vol. 7048, p. 704807, 2008, doi: 10.1117/12.795428.I. 60904-9, International Standard International Standard, vol. 2003. 2003, p. 13V. Esen, Ş. Sağlam, and B. Oral, “Light sources of solar simulators for photovoltaic devices: A review,” Renew. Sustain. Energy Rev., vol. 77, no. March, pp. 1240–1250, 2017, doi: 10.1016/j.rser.2017.03.062.G. Leary, G. Switzer, G. Kuntz, and T. Kaiser, “Comparison of xenon lamp-based and led-based solar simulators,” 2017 IEEE 44th Photovolt. Spec. Conf. PVSC 2017, pp. 6–9, 2017, doi: 10.1109/PVSC.2017.8366725.R. J. Matson, K. A. Emery, and R. E. Bird, “Terrestrial solar spectra, solar simulation and solar cell short-circuit current calibration: A review,” Sol. Cells, vol. 11, no. 2, pp. 105–145, 1984, doi: 10.1016/0379-6787(84)90022-X.W. Wang and B. Laumert, “Simulate a ‘Sun’ for Solar Research: A Literature Review of Solar Simulator Technology,” pp. 1–37, 2014.J. C. Campo, M. A. Perez, J. M. Mezquita, and J. Sebastian, “Circuit-design criteria for improvement of xenon flash-lamp performance (lamp life, light-pulse, narrowness, uniformity of light intensity in a series of flashes),” pp. 1057–1061, 2002, doi: 10.1109/apec.1997.575780.N. Selvaganesan and S. Lecturer, “A 24-Pulse AC-DC Converter For Improving Power Quality Using Fork Connected Transformer,” no. June, pp. 1–8, 2009.H. D. Division, “Xenon Flash Light IGBT Application Note,” 2014.J. R. Oliver and F. S. Barnes, “A Comparison of Rare-Gas Flashlamps,” IEEE J. Quantum Electron., vol. 5, no. 5, pp. 232–237, 1969, doi: 10.1109/JQE.1969.1075765.J. Fiz, “Study of Single-Mesh LC Flashlamp Driving Circuit for Xenon Flashlamp,” vol. 3, pp. 95–98, 2008.H. Akiyama, M. Kristiansen, H. Krompholz, and B. Maas, “Current-Voltage Characteristics of a High-Current Pulsed Discharge in Air,” IEEE Trans. Plasma Sci., vol. 16, no. 2, pp. 312–316, 1988, doi: 10.1109/27.3830.W. Yao, F. Blaabjerg, X. Zhang, Y. Yang, and Z. Gao, “Zero sequence blocking transformers for multi-pulse rectifier in aerospace applications,” 2014 IEEE Energy Convers. Congr. Expo. ECCE 2014, pp. 999–1006, 2014, doi: 10.1109/ECCE.2014.6953508.D. F. D. Narváez, “Modelado de un convertidor ca/cc trifásico para el análisis de la distorsión armónica .,” p. 82, 2011.Limones Pozos Cesar A and Mendoza Rivera José, “Diseño De Un Rectificador Trifásico Con Convertidor Reductor,” ResearchGate, no. August, 2019.EstudiantesInvestigadoresPúblico generalLICENSElicense.txtlicense.txttext/plain; charset=utf-85879https://repositorio.unal.edu.co/bitstream/unal/85605/1/license.txteb34b1cf90b7e1103fc9dfd26be24b4aMD51ORIGINAL1000467473.2023 (1).pdf1000467473.2023 (1).pdfTesis de Maestría en Ingeniería - Ingeniería Eléctricaapplication/pdf5084505https://repositorio.unal.edu.co/bitstream/unal/85605/2/1000467473.2023%20%281%29.pdf24cb8488d903853657f1f145cea535d7MD52THUMBNAIL1000467473.2023 (1).pdf.jpg1000467473.2023 (1).pdf.jpgGenerated Thumbnailimage/jpeg5236https://repositorio.unal.edu.co/bitstream/unal/85605/3/1000467473.2023%20%281%29.pdf.jpgda971c5304688b8ba278a07258a901d1MD53unal/85605oai:repositorio.unal.edu.co:unal/856052024-02-02 23:03:40.403Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.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 |