Straight-line conventional transient rate analysis for long homogeneous and heterogeneous reservoirs

A linear flow regime is a very important flow regime presented in fractured wells, horizontal wells and long reservoirs. Either pressure-transient analysis or rate-transient analysis may be affected by a linear flow regime. In the case the case of production rate most of the analysis is conducted by...

Full description

Autores:
Escobar Macualo, Freddy Humberto
Rojas Rodriguez, Margarita María
Cantillo Silva, José Humberto
Tipo de recurso:
Article of journal
Fecha de publicación:
2012
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/40658
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/40658
http://bdigital.unal.edu.co/30755/
Palabra clave:
Linear flow
parabolic flow
reservoir width
well-flowing pressure
Rights
openAccess
License
Atribución-NoComercial 4.0 Internacional
id UNACIONAL2_db7be84ac7aea011a8cde8c72bab4ddb
oai_identifier_str oai:repositorio.unal.edu.co:unal/40658
network_acronym_str UNACIONAL2
network_name_str Universidad Nacional de Colombia
repository_id_str
spelling Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Escobar Macualo, Freddy Humberto71435375-c905-4080-a061-6b4e1525f024300Rojas Rodriguez, Margarita María3a6ee255-1383-4297-80b7-6faf6e81ac70300Cantillo Silva, José Humberto96a0ff58-dc2c-4d34-973c-8001a4a038a43002019-06-28T09:37:51Z2019-06-28T09:37:51Z2012https://repositorio.unal.edu.co/handle/unal/40658http://bdigital.unal.edu.co/30755/A linear flow regime is a very important flow regime presented in fractured wells, horizontal wells and long reservoirs. Either pressure-transient analysis or rate-transient analysis may be affected by a linear flow regime. In the case the case of production rate most of the analysis is conducted by decline-curve fitting and little attention has been given to rate-transient analysis. This paper presents the governing equations used for rate-transient analysis in elongated systems and provides examples using the conventional analysis. The methodology allows for the estimation of reservoir permeability, reservoir width and geometrical skin factors. If the test is long enough, reservoir drainage area and well position inside the reservoir can also be determined. The methodology was successfully verified by its application to synthetic cases.application/pdfspaUniversidad Nacional de Colombia Sede Medellínhttp://revistas.unal.edu.co/index.php/dyna/article/view/29666Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaDyna; Vol. 79, núm. 172 (2012); 156-163 DYNA; Vol. 79, núm. 172 (2012); 156-163 2346-2183 0012-7353Escobar Macualo, Freddy Humberto and Rojas Rodriguez, Margarita María and Cantillo Silva, José Humberto (2012) Straight-line conventional transient rate analysis for long homogeneous and heterogeneous reservoirs. Dyna; Vol. 79, núm. 172 (2012); 156-163 DYNA; Vol. 79, núm. 172 (2012); 156-163 2346-2183 0012-7353 .Straight-line conventional transient rate analysis for long homogeneous and heterogeneous reservoirsArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTLinear flowparabolic flowreservoir widthwell-flowing pressureORIGINAL29666-158237-1-PB.htmltext/html26765https://repositorio.unal.edu.co/bitstream/unal/40658/1/29666-158237-1-PB.html4dcd49af234fc7bb65e69b3d85178d80MD5129666-106549-1-PB.pdfapplication/pdf2755034https://repositorio.unal.edu.co/bitstream/unal/40658/2/29666-106549-1-PB.pdf82f8bc54883980c367c38db00960ac57MD52THUMBNAIL29666-106549-1-PB.pdf.jpg29666-106549-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg9571https://repositorio.unal.edu.co/bitstream/unal/40658/3/29666-106549-1-PB.pdf.jpgc74cd1b320fa16b726506d9a5a6d4aeeMD53unal/40658oai:repositorio.unal.edu.co:unal/406582023-01-30 23:03:41.984Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co
dc.title.spa.fl_str_mv Straight-line conventional transient rate analysis for long homogeneous and heterogeneous reservoirs
title Straight-line conventional transient rate analysis for long homogeneous and heterogeneous reservoirs
spellingShingle Straight-line conventional transient rate analysis for long homogeneous and heterogeneous reservoirs
Linear flow
parabolic flow
reservoir width
well-flowing pressure
title_short Straight-line conventional transient rate analysis for long homogeneous and heterogeneous reservoirs
title_full Straight-line conventional transient rate analysis for long homogeneous and heterogeneous reservoirs
title_fullStr Straight-line conventional transient rate analysis for long homogeneous and heterogeneous reservoirs
title_full_unstemmed Straight-line conventional transient rate analysis for long homogeneous and heterogeneous reservoirs
title_sort Straight-line conventional transient rate analysis for long homogeneous and heterogeneous reservoirs
dc.creator.fl_str_mv Escobar Macualo, Freddy Humberto
Rojas Rodriguez, Margarita María
Cantillo Silva, José Humberto
dc.contributor.author.spa.fl_str_mv Escobar Macualo, Freddy Humberto
Rojas Rodriguez, Margarita María
Cantillo Silva, José Humberto
dc.subject.proposal.spa.fl_str_mv Linear flow
parabolic flow
reservoir width
well-flowing pressure
topic Linear flow
parabolic flow
reservoir width
well-flowing pressure
description A linear flow regime is a very important flow regime presented in fractured wells, horizontal wells and long reservoirs. Either pressure-transient analysis or rate-transient analysis may be affected by a linear flow regime. In the case the case of production rate most of the analysis is conducted by decline-curve fitting and little attention has been given to rate-transient analysis. This paper presents the governing equations used for rate-transient analysis in elongated systems and provides examples using the conventional analysis. The methodology allows for the estimation of reservoir permeability, reservoir width and geometrical skin factors. If the test is long enough, reservoir drainage area and well position inside the reservoir can also be determined. The methodology was successfully verified by its application to synthetic cases.
publishDate 2012
dc.date.issued.spa.fl_str_mv 2012
dc.date.accessioned.spa.fl_str_mv 2019-06-28T09:37:51Z
dc.date.available.spa.fl_str_mv 2019-06-28T09:37:51Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.uri.none.fl_str_mv https://repositorio.unal.edu.co/handle/unal/40658
dc.identifier.eprints.spa.fl_str_mv http://bdigital.unal.edu.co/30755/
url https://repositorio.unal.edu.co/handle/unal/40658
http://bdigital.unal.edu.co/30755/
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv http://revistas.unal.edu.co/index.php/dyna/article/view/29666
dc.relation.ispartof.spa.fl_str_mv Universidad Nacional de Colombia Revistas electrónicas UN Dyna
Dyna
dc.relation.ispartofseries.none.fl_str_mv Dyna; Vol. 79, núm. 172 (2012); 156-163 DYNA; Vol. 79, núm. 172 (2012); 156-163 2346-2183 0012-7353
dc.relation.references.spa.fl_str_mv Escobar Macualo, Freddy Humberto and Rojas Rodriguez, Margarita María and Cantillo Silva, José Humberto (2012) Straight-line conventional transient rate analysis for long homogeneous and heterogeneous reservoirs. Dyna; Vol. 79, núm. 172 (2012); 156-163 DYNA; Vol. 79, núm. 172 (2012); 156-163 2346-2183 0012-7353 .
dc.rights.spa.fl_str_mv Derechos reservados - Universidad Nacional de Colombia
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.license.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional
dc.rights.uri.spa.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv Atribución-NoComercial 4.0 Internacional
Derechos reservados - Universidad Nacional de Colombia
http://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Nacional de Colombia Sede Medellín
institution Universidad Nacional de Colombia
bitstream.url.fl_str_mv https://repositorio.unal.edu.co/bitstream/unal/40658/1/29666-158237-1-PB.html
https://repositorio.unal.edu.co/bitstream/unal/40658/2/29666-106549-1-PB.pdf
https://repositorio.unal.edu.co/bitstream/unal/40658/3/29666-106549-1-PB.pdf.jpg
bitstream.checksum.fl_str_mv 4dcd49af234fc7bb65e69b3d85178d80
82f8bc54883980c367c38db00960ac57
c74cd1b320fa16b726506d9a5a6d4aee
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad Nacional de Colombia
repository.mail.fl_str_mv repositorio_nal@unal.edu.co
_version_ 1814089356785221632