Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia
Introduction: In Colombia, due to the difficult access to health services and to geographic conditions, the implementation and innovation of telemedicine technological tools is a priority. Having a validated vital signs monitor (VSM) improves proper medical treatment and diagnosis.Objective: To desi...
- Autores:
-
Rodríguez-Salazar, Leonardo Andrés
Gamboa-Delgado, Edna Magaly
Plata Rangel, Sherneyko
Mantilla-Prada, Oscar Alberto
Sarmiento-Caraballo, Eugenio
Rincón-Riveros, José Domingo
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2016
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/65184
- Acceso en línea:
- https://repositorio.unal.edu.co/handle/unal/65184
http://bdigital.unal.edu.co/66207/
- Palabra clave:
- 61 Ciencias médicas; Medicina / Medicine and health
Physiologic Monitoring
Vital Sign
Validation Studies
Monitoreo fisiológico
Signos vitales
Estudios de validación
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional
id |
UNACIONAL2_d7c47cc2a1240ca0452ae93a3694f1bb |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/65184 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
dc.title.spa.fl_str_mv |
Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia |
title |
Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia |
spellingShingle |
Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia 61 Ciencias médicas; Medicina / Medicine and health Physiologic Monitoring Vital Sign Validation Studies Monitoreo fisiológico Signos vitales Estudios de validación |
title_short |
Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia |
title_full |
Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia |
title_fullStr |
Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia |
title_full_unstemmed |
Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia |
title_sort |
Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia |
dc.creator.fl_str_mv |
Rodríguez-Salazar, Leonardo Andrés Gamboa-Delgado, Edna Magaly Plata Rangel, Sherneyko Mantilla-Prada, Oscar Alberto Sarmiento-Caraballo, Eugenio Rincón-Riveros, José Domingo |
dc.contributor.author.spa.fl_str_mv |
Rodríguez-Salazar, Leonardo Andrés Gamboa-Delgado, Edna Magaly Plata Rangel, Sherneyko Mantilla-Prada, Oscar Alberto Sarmiento-Caraballo, Eugenio Rincón-Riveros, José Domingo |
dc.subject.ddc.spa.fl_str_mv |
61 Ciencias médicas; Medicina / Medicine and health |
topic |
61 Ciencias médicas; Medicina / Medicine and health Physiologic Monitoring Vital Sign Validation Studies Monitoreo fisiológico Signos vitales Estudios de validación |
dc.subject.proposal.spa.fl_str_mv |
Physiologic Monitoring Vital Sign Validation Studies Monitoreo fisiológico Signos vitales Estudios de validación |
description |
Introduction: In Colombia, due to the difficult access to health services and to geographic conditions, the implementation and innovation of telemedicine technological tools is a priority. Having a validated vital signs monitor (VSM) improves proper medical treatment and diagnosis.Objective: To design and perform clinical trials for the SignCare VSM.Materials and methods: A device for continuous monitoring of electrocardiography, respiration, oxygen saturation, temperature and noninvasive blood pressure (NIBP) was designed. This device was validated in a laboratory in order to ensure a robust prototype, close to the level of commercial medical devices. Clinical trials were performed through a cross-section study with 98 patients, whose vital signs were measured using the SignCare monitor and a commercial monitor. These two measurements were compared using Pearson’s correlation coefficients.Results: There were no statistically significant differences between the results obtained with the SignCare VSM and the commercial monitor. The highest correlations were found for the following items: heart rate by electrocardiogram (r=0.844), heart rate by oxymetry (r=0.821), body temperature (r=0.895), systolic blood pressure (r=0.780), and diastolic blood pressure (r=0.811).Conclusions: The SignCare device is as reliable as the commercial monitor in the qualitative detection of morphologic alterations of electrocardiogram records, as well as in breathing, temperature, oxygen saturation and blood pressure parameters, which makes it recommendable for clinical use in adult population. |
publishDate |
2016 |
dc.date.issued.spa.fl_str_mv |
2016-07-01 |
dc.date.accessioned.spa.fl_str_mv |
2019-07-02T23:57:14Z |
dc.date.available.spa.fl_str_mv |
2019-07-02T23:57:14Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.coarversion.spa.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.issn.spa.fl_str_mv |
ISSN: 2357-3848 |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/65184 |
dc.identifier.eprints.spa.fl_str_mv |
http://bdigital.unal.edu.co/66207/ |
identifier_str_mv |
ISSN: 2357-3848 |
url |
https://repositorio.unal.edu.co/handle/unal/65184 http://bdigital.unal.edu.co/66207/ |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.spa.fl_str_mv |
https://revistas.unal.edu.co/index.php/revfacmed/article/view/49339 |
dc.relation.ispartof.spa.fl_str_mv |
Universidad Nacional de Colombia Revistas electrónicas UN Revista de la Facultad de Medicina Revista de la Facultad de Medicina |
dc.relation.references.spa.fl_str_mv |
Rodríguez-Salazar, Leonardo Andrés and Gamboa-Delgado, Edna Magaly and Plata Rangel, Sherneyko and Mantilla-Prada, Oscar Alberto and Sarmiento-Caraballo, Eugenio and Rincón-Riveros, José Domingo (2016) Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia. Revista de la Facultad de Medicina, 64 (3). pp. 459-463. ISSN 2357-3848 |
dc.rights.spa.fl_str_mv |
Derechos reservados - Universidad Nacional de Colombia |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial 4.0 Internacional Derechos reservados - Universidad Nacional de Colombia http://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Universidad Nacional de Colombia - Sede Bogotá - Facultad de Medicina |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/65184/1/49339-315086-1-PB.pdf https://repositorio.unal.edu.co/bitstream/unal/65184/2/49339-315086-1-PB.pdf.jpg |
bitstream.checksum.fl_str_mv |
dedceb092bc1d91f9f3c20bd712f00da 1dbc8c01934a8dd8567934bcd205d22a |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814089737438232576 |
spelling |
Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Rodríguez-Salazar, Leonardo Andrés98444977-1e69-4e67-807e-07538326873d300Gamboa-Delgado, Edna Magaly472cc6c9-7fbf-4a9c-a65a-7d6c00797fc1300Plata Rangel, Sherneyko1d3a23a1-f8d9-4d37-a146-e3f33462e9c4300Mantilla-Prada, Oscar Albertob93252a0-3182-4212-9005-b4ecb2a9b36e300Sarmiento-Caraballo, Eugenioc376ec4a-278c-4289-b171-9a4e39b25607300Rincón-Riveros, José Domingoe3ec1e8a-634d-4717-a1b9-c9dfe61553be3002019-07-02T23:57:14Z2019-07-02T23:57:14Z2016-07-01ISSN: 2357-3848https://repositorio.unal.edu.co/handle/unal/65184http://bdigital.unal.edu.co/66207/Introduction: In Colombia, due to the difficult access to health services and to geographic conditions, the implementation and innovation of telemedicine technological tools is a priority. Having a validated vital signs monitor (VSM) improves proper medical treatment and diagnosis.Objective: To design and perform clinical trials for the SignCare VSM.Materials and methods: A device for continuous monitoring of electrocardiography, respiration, oxygen saturation, temperature and noninvasive blood pressure (NIBP) was designed. This device was validated in a laboratory in order to ensure a robust prototype, close to the level of commercial medical devices. Clinical trials were performed through a cross-section study with 98 patients, whose vital signs were measured using the SignCare monitor and a commercial monitor. These two measurements were compared using Pearson’s correlation coefficients.Results: There were no statistically significant differences between the results obtained with the SignCare VSM and the commercial monitor. The highest correlations were found for the following items: heart rate by electrocardiogram (r=0.844), heart rate by oxymetry (r=0.821), body temperature (r=0.895), systolic blood pressure (r=0.780), and diastolic blood pressure (r=0.811).Conclusions: The SignCare device is as reliable as the commercial monitor in the qualitative detection of morphologic alterations of electrocardiogram records, as well as in breathing, temperature, oxygen saturation and blood pressure parameters, which makes it recommendable for clinical use in adult population.Introducción. Debido a las dificultades geográficas y de acceso a los servicios de salud en Colombia, la implementación e innovación con herramientas de telemedicina se convierte en un tema prioritario; contar con un monitor de signos vitales validado favorece el tratamiento médico oportuno.Objetivos. Diseñar y realizar la validación clínica del monitor de signos vitales SignCare.Materiales y métodos. Se diseñó un equipo para el monitoreo constante de las señales de electrocardiografía, respiración, saturación de oxígeno, temperatura y presión arterial no invasiva. El dispositivo fue validado en el laboratorio para asegurar un prototipo robusto a nivel de dispositivos médicos comerciales. La validación clínica se hizo mediante un estudio de corte transversal en 98 pacientes a los que se les realizaron mediciones con el monitor SignCare y con un monitor comercial. Se compararon estas dos mediciones mediante coeficientes de correlación de Pearson.Resultados. No hubo diferencias estadísticamente significativas en cuanto a los resultados obtenidos con el monitor SignCare y con el monitor comercial. Las mayores correlaciones se presentaron en la frecuencia cardíaca por electrocardiograma (r=0.844), frecuencia cardíaca por oximetría (r=0.821), temperatura corporal (r=0.895), tensión arterial sistólica (r=0.780) y tensión arterial diastólica (0.811).Conclusiones. El monitor SignCare es tan confiable como el monitor comercial para la detección cualitativa de alteraciones morfológicas del registro electrocardiográfico, lo que hace posible su recomendación para uso clínico en población adulta.application/pdfspaUniversidad Nacional de Colombia - Sede Bogotá - Facultad de Medicinahttps://revistas.unal.edu.co/index.php/revfacmed/article/view/49339Universidad Nacional de Colombia Revistas electrónicas UN Revista de la Facultad de MedicinaRevista de la Facultad de MedicinaRodríguez-Salazar, Leonardo Andrés and Gamboa-Delgado, Edna Magaly and Plata Rangel, Sherneyko and Mantilla-Prada, Oscar Alberto and Sarmiento-Caraballo, Eugenio and Rincón-Riveros, José Domingo (2016) Clinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de Colombia. Revista de la Facultad de Medicina, 64 (3). pp. 459-463. ISSN 2357-384861 Ciencias médicas; Medicina / Medicine and healthPhysiologic MonitoringVital SignValidation StudiesMonitoreo fisiológicoSignos vitalesEstudios de validaciónClinical validation study of the SignCare Vital Signs Monitor of Fundación Cardiovascular de ColombiaArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL49339-315086-1-PB.pdfapplication/pdf658073https://repositorio.unal.edu.co/bitstream/unal/65184/1/49339-315086-1-PB.pdfdedceb092bc1d91f9f3c20bd712f00daMD51THUMBNAIL49339-315086-1-PB.pdf.jpg49339-315086-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg8712https://repositorio.unal.edu.co/bitstream/unal/65184/2/49339-315086-1-PB.pdf.jpg1dbc8c01934a8dd8567934bcd205d22aMD52unal/65184oai:repositorio.unal.edu.co:unal/651842024-05-09 23:09:04.244Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co |