Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT
The inspection of radiant heating floors requires the use of non-destructive techniques, trying to minimize inspection impact, time and cost, and maximize the information acquired so that the best possible diagnosis is given. With this goal, we propose the application of infrared thermography (IRT)...
- Autores:
-
Lagüela Lopez, Susana
Solla Carracelas, Mercedes
Díaz Vilariño, Lucía
Armesto González, Julia
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2015
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/60751
- Acceso en línea:
- https://repositorio.unal.edu.co/handle/unal/60751
http://bdigital.unal.edu.co/59083/
- Palabra clave:
- 62 Ingeniería y operaciones afines / Engineering
NDT
infrared thermography
ground penetrating radar
radiant heating floor
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional
id |
UNACIONAL2_c6c530c0809741ffc05e3d62a731590a |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/60751 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
spelling |
Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Lagüela Lopez, Susana3367ca67-3635-445e-a440-bbfa79bbcb06300Solla Carracelas, Mercedes81df476e-d0b4-4ff2-9e13-b7446a0bec7f300Díaz Vilariño, Lucíae716a29c-3f02-4bb9-a008-5399d0094386300Armesto González, Juliad96797db-d4e2-4cae-be75-fe6db8cd21423002019-07-02T19:01:49Z2019-07-02T19:01:49Z2015-03-01ISSN: 2346-2183https://repositorio.unal.edu.co/handle/unal/60751http://bdigital.unal.edu.co/59083/The inspection of radiant heating floors requires the use of non-destructive techniques, trying to minimize inspection impact, time and cost, and maximize the information acquired so that the best possible diagnosis is given. With this goal, we propose the application of infrared thermography (IRT) and ground penetrating radar (GPR) for the inspection of radiant heating floors with different floor coatings, in order to evaluate the capabilities and information acquirable with each technique. Specifically, two common floor coatings have been inspected: ceramic tiles and parquet flooring. Results show that each technique provides different information: condition of the pipelines (IRT), geometry and configuration (GPR), concluding that the optimal inspection is constituted by the combination of the two techniques.application/pdfspaUniversidad Nacional de Colombia (Sede Medellín). Facultad de Minas.https://revistas.unal.edu.co/index.php/dyna/article/view/43913Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaLagüela Lopez, Susana and Solla Carracelas, Mercedes and Díaz Vilariño, Lucía and Armesto González, Julia (2015) Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT. DYNA, 82 (190). pp. 221-226. ISSN 2346-218362 Ingeniería y operaciones afines / EngineeringNDTinfrared thermographyground penetrating radarradiant heating floorInspection of radiant heating floor applying non-destructive testing techniques: GPR and IRTArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL43913-246731-1-PB.pdfapplication/pdf1919255https://repositorio.unal.edu.co/bitstream/unal/60751/1/43913-246731-1-PB.pdf3d296bd5ffbad517658c32ac062a2cddMD51THUMBNAIL43913-246731-1-PB.pdf.jpg43913-246731-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg9313https://repositorio.unal.edu.co/bitstream/unal/60751/2/43913-246731-1-PB.pdf.jpgd5e81601b4326678e6a104d05fa2003dMD52unal/60751oai:repositorio.unal.edu.co:unal/607512023-04-08 23:05:11.874Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co |
dc.title.spa.fl_str_mv |
Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT |
title |
Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT |
spellingShingle |
Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT 62 Ingeniería y operaciones afines / Engineering NDT infrared thermography ground penetrating radar radiant heating floor |
title_short |
Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT |
title_full |
Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT |
title_fullStr |
Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT |
title_full_unstemmed |
Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT |
title_sort |
Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT |
dc.creator.fl_str_mv |
Lagüela Lopez, Susana Solla Carracelas, Mercedes Díaz Vilariño, Lucía Armesto González, Julia |
dc.contributor.author.spa.fl_str_mv |
Lagüela Lopez, Susana Solla Carracelas, Mercedes Díaz Vilariño, Lucía Armesto González, Julia |
dc.subject.ddc.spa.fl_str_mv |
62 Ingeniería y operaciones afines / Engineering |
topic |
62 Ingeniería y operaciones afines / Engineering NDT infrared thermography ground penetrating radar radiant heating floor |
dc.subject.proposal.spa.fl_str_mv |
NDT infrared thermography ground penetrating radar radiant heating floor |
description |
The inspection of radiant heating floors requires the use of non-destructive techniques, trying to minimize inspection impact, time and cost, and maximize the information acquired so that the best possible diagnosis is given. With this goal, we propose the application of infrared thermography (IRT) and ground penetrating radar (GPR) for the inspection of radiant heating floors with different floor coatings, in order to evaluate the capabilities and information acquirable with each technique. Specifically, two common floor coatings have been inspected: ceramic tiles and parquet flooring. Results show that each technique provides different information: condition of the pipelines (IRT), geometry and configuration (GPR), concluding that the optimal inspection is constituted by the combination of the two techniques. |
publishDate |
2015 |
dc.date.issued.spa.fl_str_mv |
2015-03-01 |
dc.date.accessioned.spa.fl_str_mv |
2019-07-02T19:01:49Z |
dc.date.available.spa.fl_str_mv |
2019-07-02T19:01:49Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.coarversion.spa.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.issn.spa.fl_str_mv |
ISSN: 2346-2183 |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/60751 |
dc.identifier.eprints.spa.fl_str_mv |
http://bdigital.unal.edu.co/59083/ |
identifier_str_mv |
ISSN: 2346-2183 |
url |
https://repositorio.unal.edu.co/handle/unal/60751 http://bdigital.unal.edu.co/59083/ |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.spa.fl_str_mv |
https://revistas.unal.edu.co/index.php/dyna/article/view/43913 |
dc.relation.ispartof.spa.fl_str_mv |
Universidad Nacional de Colombia Revistas electrónicas UN Dyna Dyna |
dc.relation.references.spa.fl_str_mv |
Lagüela Lopez, Susana and Solla Carracelas, Mercedes and Díaz Vilariño, Lucía and Armesto González, Julia (2015) Inspection of radiant heating floor applying non-destructive testing techniques: GPR and IRT. DYNA, 82 (190). pp. 221-226. ISSN 2346-2183 |
dc.rights.spa.fl_str_mv |
Derechos reservados - Universidad Nacional de Colombia |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial 4.0 Internacional Derechos reservados - Universidad Nacional de Colombia http://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Universidad Nacional de Colombia (Sede Medellín). Facultad de Minas. |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/60751/1/43913-246731-1-PB.pdf https://repositorio.unal.edu.co/bitstream/unal/60751/2/43913-246731-1-PB.pdf.jpg |
bitstream.checksum.fl_str_mv |
3d296bd5ffbad517658c32ac062a2cdd d5e81601b4326678e6a104d05fa2003d |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814089482994974720 |