Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards

This paper presents the first systematic atmospheric corrosion assessment in Bogota. Main facts about the study are related with special characteristics of the City, such as population (more than eight million inhabitants), and altitude (2600 m over the sea level). Relative humidity, temperature, an...

Full description

Autores:
Ríos Rojas, John Fredy
Escobar Ocampo, Diego
Hernández García, Edwin Arbey
Arroyave Posada, Carlos Enrique
Tipo de recurso:
Article of journal
Fecha de publicación:
2015
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/60755
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/60755
http://bdigital.unal.edu.co/59087/
Palabra clave:
62 Ingeniería y operaciones afines / Engineering
Brook’s Index
ISO 9223 Standard
relative humidity (RH)
time of wetness (TOW)
plain carbon steel
atmospheric pollutants.
Rights
openAccess
License
Atribución-NoComercial 4.0 Internacional
id UNACIONAL2_b84850d8caeec56ac3747b07f6ef33ac
oai_identifier_str oai:repositorio.unal.edu.co:unal/60755
network_acronym_str UNACIONAL2
network_name_str Universidad Nacional de Colombia
repository_id_str
spelling Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Ríos Rojas, John Fredy6f4580fe-3403-4c65-98c1-0fcf9e4e8908300Escobar Ocampo, Diego91f56a4c-a879-4010-bec6-6afe8ec3df1c300Hernández García, Edwin Arbey8b11a0c8-b12d-49eb-a9ed-5b32722b63cf300Arroyave Posada, Carlos Enrique79f69539-041e-4e83-81dc-96fa955c54893002019-07-02T19:02:22Z2019-07-02T19:02:22Z2015-03-01ISSN: 2346-2183https://repositorio.unal.edu.co/handle/unal/60755http://bdigital.unal.edu.co/59087/This paper presents the first systematic atmospheric corrosion assessment in Bogota. Main facts about the study are related with special characteristics of the City, such as population (more than eight million inhabitants), and altitude (2600 m over the sea level). Relative humidity, temperature, and SO2 concentration were measured. Simultaneously, corrosion rate of AIS/SAE 1006 plain steel was measured along one year. Results show that atmospheric corrosion is between C2 – C3 levels, according to the ISO 9223 standard. Nevertheless, estimations from meteorological parameters produce lower corrosivities and, taking into account SO2 concentrations, corrosivities in places with higher relative humidity, are higher than corrosivities measured on steel coupons. In general, the main pollution problem is particulate matter, but higher corrosion rates were directly associated with SO2 levels. Gaps between found results and international estimation methodologies are evident. Some explanations about that, are proposed.application/pdfspaUniversidad Nacional de Colombia (Sede Medellín). Facultad de Minas.https://revistas.unal.edu.co/index.php/dyna/article/view/46256Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaRíos Rojas, John Fredy and Escobar Ocampo, Diego and Hernández García, Edwin Arbey and Arroyave Posada, Carlos Enrique (2015) Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards. DYNA, 82 (190). pp. 128-137. ISSN 2346-218362 Ingeniería y operaciones afines / EngineeringBrook’s IndexISO 9223 Standardrelative humidity (RH)time of wetness (TOW)plain carbon steelatmospheric pollutants.Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standardsArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL46256-245779-1-PB.pdfapplication/pdf1374112https://repositorio.unal.edu.co/bitstream/unal/60755/1/46256-245779-1-PB.pdf8c1c62ffbd8941c14ab0d9bc595ee031MD51THUMBNAIL46256-245779-1-PB.pdf.jpg46256-245779-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg9360https://repositorio.unal.edu.co/bitstream/unal/60755/2/46256-245779-1-PB.pdf.jpg3e60d8d1d4f0c0c1750f96c157dbd5cfMD52unal/60755oai:repositorio.unal.edu.co:unal/607552024-04-14 23:11:52.156Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co
dc.title.spa.fl_str_mv Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards
title Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards
spellingShingle Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards
62 Ingeniería y operaciones afines / Engineering
Brook’s Index
ISO 9223 Standard
relative humidity (RH)
time of wetness (TOW)
plain carbon steel
atmospheric pollutants.
title_short Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards
title_full Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards
title_fullStr Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards
title_full_unstemmed Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards
title_sort Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards
dc.creator.fl_str_mv Ríos Rojas, John Fredy
Escobar Ocampo, Diego
Hernández García, Edwin Arbey
Arroyave Posada, Carlos Enrique
dc.contributor.author.spa.fl_str_mv Ríos Rojas, John Fredy
Escobar Ocampo, Diego
Hernández García, Edwin Arbey
Arroyave Posada, Carlos Enrique
dc.subject.ddc.spa.fl_str_mv 62 Ingeniería y operaciones afines / Engineering
topic 62 Ingeniería y operaciones afines / Engineering
Brook’s Index
ISO 9223 Standard
relative humidity (RH)
time of wetness (TOW)
plain carbon steel
atmospheric pollutants.
dc.subject.proposal.spa.fl_str_mv Brook’s Index
ISO 9223 Standard
relative humidity (RH)
time of wetness (TOW)
plain carbon steel
atmospheric pollutants.
description This paper presents the first systematic atmospheric corrosion assessment in Bogota. Main facts about the study are related with special characteristics of the City, such as population (more than eight million inhabitants), and altitude (2600 m over the sea level). Relative humidity, temperature, and SO2 concentration were measured. Simultaneously, corrosion rate of AIS/SAE 1006 plain steel was measured along one year. Results show that atmospheric corrosion is between C2 – C3 levels, according to the ISO 9223 standard. Nevertheless, estimations from meteorological parameters produce lower corrosivities and, taking into account SO2 concentrations, corrosivities in places with higher relative humidity, are higher than corrosivities measured on steel coupons. In general, the main pollution problem is particulate matter, but higher corrosion rates were directly associated with SO2 levels. Gaps between found results and international estimation methodologies are evident. Some explanations about that, are proposed.
publishDate 2015
dc.date.issued.spa.fl_str_mv 2015-03-01
dc.date.accessioned.spa.fl_str_mv 2019-07-02T19:02:22Z
dc.date.available.spa.fl_str_mv 2019-07-02T19:02:22Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.issn.spa.fl_str_mv ISSN: 2346-2183
dc.identifier.uri.none.fl_str_mv https://repositorio.unal.edu.co/handle/unal/60755
dc.identifier.eprints.spa.fl_str_mv http://bdigital.unal.edu.co/59087/
identifier_str_mv ISSN: 2346-2183
url https://repositorio.unal.edu.co/handle/unal/60755
http://bdigital.unal.edu.co/59087/
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv https://revistas.unal.edu.co/index.php/dyna/article/view/46256
dc.relation.ispartof.spa.fl_str_mv Universidad Nacional de Colombia Revistas electrónicas UN Dyna
Dyna
dc.relation.references.spa.fl_str_mv Ríos Rojas, John Fredy and Escobar Ocampo, Diego and Hernández García, Edwin Arbey and Arroyave Posada, Carlos Enrique (2015) Atmospheric corrosivity in Bogota as a very high-altitude metropolis questions international standards. DYNA, 82 (190). pp. 128-137. ISSN 2346-2183
dc.rights.spa.fl_str_mv Derechos reservados - Universidad Nacional de Colombia
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.license.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional
dc.rights.uri.spa.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv Atribución-NoComercial 4.0 Internacional
Derechos reservados - Universidad Nacional de Colombia
http://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Nacional de Colombia (Sede Medellín). Facultad de Minas.
institution Universidad Nacional de Colombia
bitstream.url.fl_str_mv https://repositorio.unal.edu.co/bitstream/unal/60755/1/46256-245779-1-PB.pdf
https://repositorio.unal.edu.co/bitstream/unal/60755/2/46256-245779-1-PB.pdf.jpg
bitstream.checksum.fl_str_mv 8c1c62ffbd8941c14ab0d9bc595ee031
3e60d8d1d4f0c0c1750f96c157dbd5cf
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad Nacional de Colombia
repository.mail.fl_str_mv repositorio_nal@unal.edu.co
_version_ 1814090217149169664