Reference values for spirometric variables for allegedly healthy workers

Introduction: Spirometry in workers exposed to air pollutants allows for early identification of lung function impairment. Reference values (RV) for spirometric variables (SV) obtained in Cuban workers (CW) are not available.Objective: To obtain adequate SV-specific RV adequate for supposedly health...

Full description

Autores:
Santana-Porbén, Sergio
González-Marrero, Adamara
Valdivieso-Valdivieso, Juan Pablo
Álvarez-Porbén, Santiago
Tipo de recurso:
Article of journal
Fecha de publicación:
2018
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/64970
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/64970
http://bdigital.unal.edu.co/65993/
Palabra clave:
61 Ciencias médicas; Medicina / Medicine and health
Spirometry
Reference Values
Occupational Health
Espirometría
Valores de referencia
Trabajador
Salud laboral
Rights
openAccess
License
Atribución-NoComercial 4.0 Internacional
id UNACIONAL2_b27cc12b55010eb0c1d1ea3a95461a84
oai_identifier_str oai:repositorio.unal.edu.co:unal/64970
network_acronym_str UNACIONAL2
network_name_str Universidad Nacional de Colombia
repository_id_str
dc.title.spa.fl_str_mv Reference values for spirometric variables for allegedly healthy workers
title Reference values for spirometric variables for allegedly healthy workers
spellingShingle Reference values for spirometric variables for allegedly healthy workers
61 Ciencias médicas; Medicina / Medicine and health
Spirometry
Reference Values
Occupational Health
Espirometría
Valores de referencia
Trabajador
Salud laboral
title_short Reference values for spirometric variables for allegedly healthy workers
title_full Reference values for spirometric variables for allegedly healthy workers
title_fullStr Reference values for spirometric variables for allegedly healthy workers
title_full_unstemmed Reference values for spirometric variables for allegedly healthy workers
title_sort Reference values for spirometric variables for allegedly healthy workers
dc.creator.fl_str_mv Santana-Porbén, Sergio
González-Marrero, Adamara
Valdivieso-Valdivieso, Juan Pablo
Álvarez-Porbén, Santiago
dc.contributor.author.spa.fl_str_mv Santana-Porbén, Sergio
González-Marrero, Adamara
Valdivieso-Valdivieso, Juan Pablo
Álvarez-Porbén, Santiago
dc.subject.ddc.spa.fl_str_mv 61 Ciencias médicas; Medicina / Medicine and health
topic 61 Ciencias médicas; Medicina / Medicine and health
Spirometry
Reference Values
Occupational Health
Espirometría
Valores de referencia
Trabajador
Salud laboral
dc.subject.proposal.spa.fl_str_mv Spirometry
Reference Values
Occupational Health
Espirometría
Valores de referencia
Trabajador
Salud laboral
description Introduction: Spirometry in workers exposed to air pollutants allows for early identification of lung function impairment. Reference values (RV) for spirometric variables (SV) obtained in Cuban workers (CW) are not available.Objective: To obtain adequate SV-specific RV adequate for supposedly healthy CW.Materials and methods: Retrospective, analytical study. Forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), FEV1/FVC ratio and 25-75% forced expiration fraction for FVC (FEF25-75) values were observed in 1 088 allegedly healthy, non-smoker workers from both sexes, aged between 20 - 65 years, assisted at the Instituto Nacional de la Salud de los Trabajadores (INSAT) in Havana (Cuba) between 2009 and 2015. RV were obtained for each sex as solutions of the regression function (RF) Y=α+β x age+χ x height+ε (Y: FVC, FSV1, FEV1/FVC, FEF25-75).Results: Advanced ages were associated with lower FVC and FEV1. Taller individuals showed higher FVC and FEV1. A RF including age and height implied a higher coefficient of determination r2 and lower estimation of ε error. Behavior of SV values predicted with the locally developed equation was less biased than those obtained with other foreign equations.Conclusions: Locally developed RV may be more effective for diagnosing lung diseases in CW.
publishDate 2018
dc.date.issued.spa.fl_str_mv 2018-04-01
dc.date.accessioned.spa.fl_str_mv 2019-07-02T23:38:14Z
dc.date.available.spa.fl_str_mv 2019-07-02T23:38:14Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.issn.spa.fl_str_mv ISSN: 2357-3848
dc.identifier.uri.none.fl_str_mv https://repositorio.unal.edu.co/handle/unal/64970
dc.identifier.eprints.spa.fl_str_mv http://bdigital.unal.edu.co/65993/
identifier_str_mv ISSN: 2357-3848
url https://repositorio.unal.edu.co/handle/unal/64970
http://bdigital.unal.edu.co/65993/
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv https://revistas.unal.edu.co/index.php/revfacmed/article/view/63571
dc.relation.ispartof.spa.fl_str_mv Universidad Nacional de Colombia Revistas electrónicas UN Revista de la Facultad de Medicina
Revista de la Facultad de Medicina
dc.relation.references.spa.fl_str_mv Santana-Porbén, Sergio and González-Marrero, Adamara and Valdivieso-Valdivieso, Juan Pablo and Álvarez-Porbén, Santiago (2018) Reference values for spirometric variables for allegedly healthy workers. Revista de la Facultad de Medicina, 66 (2). pp. 179-185. ISSN 2357-3848
dc.rights.spa.fl_str_mv Derechos reservados - Universidad Nacional de Colombia
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.license.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional
dc.rights.uri.spa.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv Atribución-NoComercial 4.0 Internacional
Derechos reservados - Universidad Nacional de Colombia
http://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Nacional de Colombia - Sede Bogotá - Facultad de Medicina
institution Universidad Nacional de Colombia
bitstream.url.fl_str_mv https://repositorio.unal.edu.co/bitstream/unal/64970/1/63571-389356-1-PB.pdf
https://repositorio.unal.edu.co/bitstream/unal/64970/2/63571-389356-1-PB.pdf.jpg
bitstream.checksum.fl_str_mv 272424ab9a705c910e8c37d6c57e14af
a7a2961bbf87cb26b0bb7e69238a174f
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad Nacional de Colombia
repository.mail.fl_str_mv repositorio_nal@unal.edu.co
_version_ 1814089333941993472
spelling Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Santana-Porbén, Sergio24826db8-eaf6-43a1-a4dc-1b6ae779baa1300González-Marrero, Adamara2916531f-c145-4df1-af5a-9c78aafcdb58300Valdivieso-Valdivieso, Juan Pablocbd3db1e-9c20-4fd9-921c-0d17d915f553300Álvarez-Porbén, Santiagoa93d425c-3a1d-4032-88d9-e31f633addfe3002019-07-02T23:38:14Z2019-07-02T23:38:14Z2018-04-01ISSN: 2357-3848https://repositorio.unal.edu.co/handle/unal/64970http://bdigital.unal.edu.co/65993/Introduction: Spirometry in workers exposed to air pollutants allows for early identification of lung function impairment. Reference values (RV) for spirometric variables (SV) obtained in Cuban workers (CW) are not available.Objective: To obtain adequate SV-specific RV adequate for supposedly healthy CW.Materials and methods: Retrospective, analytical study. Forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), FEV1/FVC ratio and 25-75% forced expiration fraction for FVC (FEF25-75) values were observed in 1 088 allegedly healthy, non-smoker workers from both sexes, aged between 20 - 65 years, assisted at the Instituto Nacional de la Salud de los Trabajadores (INSAT) in Havana (Cuba) between 2009 and 2015. RV were obtained for each sex as solutions of the regression function (RF) Y=α+β x age+χ x height+ε (Y: FVC, FSV1, FEV1/FVC, FEF25-75).Results: Advanced ages were associated with lower FVC and FEV1. Taller individuals showed higher FVC and FEV1. A RF including age and height implied a higher coefficient of determination r2 and lower estimation of ε error. Behavior of SV values predicted with the locally developed equation was less biased than those obtained with other foreign equations.Conclusions: Locally developed RV may be more effective for diagnosing lung diseases in CW.Introducción. La espirometría permite identificar de forma precoz el deterioro pulmonar en trabajadores expuestos a contaminantes laborales. No se tienen valores de referencia (VR) para variables espirométricas (VE) en trabajadores cubanos (TC).Objetivo. Obtener VR para VE en TC supuestamente sanos.Materiales y métodos. Estudio retrospectivo-analítico. Se obtuvo la capacidad vital forzada (CVF), el volumen espiratorio forzado en el primer segundo (VEF1), el cociente VEF1/CVF y la fracción de la espiración forzada al 25-75% de la CVF (FEF25-75) de 1 086 TC supuestamente sanos, no fumadores, de ambos sexos, con edades entre 20 y 65 años y atendidos en el Instituto Nacional de la Salud de los Trabajadores de La Habana, Cuba, entre 2009 y 2015. Los VR se obtuvieron para cada sexo de las funciones de regresión Y=α+β x Edad+χ x Talla+ε (Y=CVF, VEF1, VEF1/CVF, FEF25-75).Resultados. Edades avanzadas se asociaron con CVF y VEF1 disminuidos; la talla elevada se asoció con mayores CVF y VEF1; una FR construida se asoció con la edad, y la talla implicó un coeficiente r2 de determinación superior y un error menor. El comportamiento de la VE predicho con la ecuación desarrollada fue menos sesgado que el observado con otras importadas.Conclusiones. Los VR construidos localmente pueden ser más efectivos en el diagnóstico de las afecciones pulmonares de los TC.application/pdfspaUniversidad Nacional de Colombia - Sede Bogotá - Facultad de Medicinahttps://revistas.unal.edu.co/index.php/revfacmed/article/view/63571Universidad Nacional de Colombia Revistas electrónicas UN Revista de la Facultad de MedicinaRevista de la Facultad de MedicinaSantana-Porbén, Sergio and González-Marrero, Adamara and Valdivieso-Valdivieso, Juan Pablo and Álvarez-Porbén, Santiago (2018) Reference values for spirometric variables for allegedly healthy workers. Revista de la Facultad de Medicina, 66 (2). pp. 179-185. ISSN 2357-384861 Ciencias médicas; Medicina / Medicine and healthSpirometryReference ValuesOccupational HealthEspirometríaValores de referenciaTrabajadorSalud laboralReference values for spirometric variables for allegedly healthy workersArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL63571-389356-1-PB.pdfapplication/pdf729416https://repositorio.unal.edu.co/bitstream/unal/64970/1/63571-389356-1-PB.pdf272424ab9a705c910e8c37d6c57e14afMD51THUMBNAIL63571-389356-1-PB.pdf.jpg63571-389356-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg8434https://repositorio.unal.edu.co/bitstream/unal/64970/2/63571-389356-1-PB.pdf.jpga7a2961bbf87cb26b0bb7e69238a174fMD52unal/64970oai:repositorio.unal.edu.co:unal/649702023-05-16 23:48:23.807Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co