Cooling efficiency in furnace design
During melting, reduction or thermal treatment of a steel charge, the input of energy (either chemical or electrical) is indispensable to guarantee the viability of the process. Under these circumstances, it will be reasonable to design the furnace lining in such a way that heat loss through the wal...
- Autores:
-
González, Roberto
Quintana Hernández, María José
Ruiz Bustinza, Íñigo
García Carcelo, Fernando
Barbés, Miguel Ángel
Florentina Barbés, María
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2013
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/42118
- Acceso en línea:
- https://repositorio.unal.edu.co/handle/unal/42118
http://bdigital.unal.edu.co/32215/
- Palabra clave:
- Metallurgy
furnaces
heat loss
lining
wear
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional
id |
UNACIONAL2_9ce692fca99f9bbd01ad8cd84f01b956 |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/42118 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
spelling |
Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2González, Roberto4083797a-c55c-4283-adc5-75e8086041e9300Quintana Hernández, María José564f1319-0e4d-4b01-babe-cc7db1f1b9ad300Ruiz Bustinza, Íñigo34b42046-40d1-4434-b7c3-e2efa9f98b25300García Carcelo, Fernandocc69108c-9a8c-433d-9cff-a5af35c301c2300Barbés, Miguel Ángelad043781-9a2c-4dd0-a4db-f8f35851d5b7300Florentina Barbés, María0b559ade-9c2b-4a22-baaf-4b13821811853002019-06-28T10:32:34Z2019-06-28T10:32:34Z2013https://repositorio.unal.edu.co/handle/unal/42118http://bdigital.unal.edu.co/32215/During melting, reduction or thermal treatment of a steel charge, the input of energy (either chemical or electrical) is indispensable to guarantee the viability of the process. Under these circumstances, it will be reasonable to design the furnace lining in such a way that heat loss through the walls is minimized. Nevertheless, it can be proved that, for some situations, it is more efficient to withdraw as much heat as possible from the walls than trying to thermally isolate the system. The work presents recommendations for the design of walls and cooling systems in furnaces obtained by quantitative analysis of temperatures reached in specific locations of the furnace using the nodal wear model. The analysis indicates that the wear process of the lining may be controlled if all the elements that intervene in the process are known.application/pdfspaUniversidad Nacional de Colombia Sede Medellínhttp://revistas.unal.edu.co/index.php/dyna/article/view/31681Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaDyna; Vol. 80, núm. 182 (2013); 131-137 DYNA; Vol. 80, núm. 182 (2013); 131-137 2346-2183 0012-7353González, Roberto and Quintana Hernández, María José and Ruiz Bustinza, Íñigo and García Carcelo, Fernando and Barbés, Miguel Ángel and Florentina Barbés, María (2013) Cooling efficiency in furnace design. Dyna; Vol. 80, núm. 182 (2013); 131-137 DYNA; Vol. 80, núm. 182 (2013); 131-137 2346-2183 0012-7353 .Cooling efficiency in furnace designArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTMetallurgyfurnacesheat lossliningwearORIGINAL31681-188334-1-PB.pdfapplication/pdf1240488https://repositorio.unal.edu.co/bitstream/unal/42118/1/31681-188334-1-PB.pdfb48dfc2a45f8709054bc406722930c14MD51THUMBNAIL31681-188334-1-PB.pdf.jpg31681-188334-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg8608https://repositorio.unal.edu.co/bitstream/unal/42118/2/31681-188334-1-PB.pdf.jpg7559b6622609f4f6c63d1ffe9f58f417MD52unal/42118oai:repositorio.unal.edu.co:unal/421182023-02-05 23:06:26.896Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co |
dc.title.spa.fl_str_mv |
Cooling efficiency in furnace design |
title |
Cooling efficiency in furnace design |
spellingShingle |
Cooling efficiency in furnace design Metallurgy furnaces heat loss lining wear |
title_short |
Cooling efficiency in furnace design |
title_full |
Cooling efficiency in furnace design |
title_fullStr |
Cooling efficiency in furnace design |
title_full_unstemmed |
Cooling efficiency in furnace design |
title_sort |
Cooling efficiency in furnace design |
dc.creator.fl_str_mv |
González, Roberto Quintana Hernández, María José Ruiz Bustinza, Íñigo García Carcelo, Fernando Barbés, Miguel Ángel Florentina Barbés, María |
dc.contributor.author.spa.fl_str_mv |
González, Roberto Quintana Hernández, María José Ruiz Bustinza, Íñigo García Carcelo, Fernando Barbés, Miguel Ángel Florentina Barbés, María |
dc.subject.proposal.spa.fl_str_mv |
Metallurgy furnaces heat loss lining wear |
topic |
Metallurgy furnaces heat loss lining wear |
description |
During melting, reduction or thermal treatment of a steel charge, the input of energy (either chemical or electrical) is indispensable to guarantee the viability of the process. Under these circumstances, it will be reasonable to design the furnace lining in such a way that heat loss through the walls is minimized. Nevertheless, it can be proved that, for some situations, it is more efficient to withdraw as much heat as possible from the walls than trying to thermally isolate the system. The work presents recommendations for the design of walls and cooling systems in furnaces obtained by quantitative analysis of temperatures reached in specific locations of the furnace using the nodal wear model. The analysis indicates that the wear process of the lining may be controlled if all the elements that intervene in the process are known. |
publishDate |
2013 |
dc.date.issued.spa.fl_str_mv |
2013 |
dc.date.accessioned.spa.fl_str_mv |
2019-06-28T10:32:34Z |
dc.date.available.spa.fl_str_mv |
2019-06-28T10:32:34Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.coarversion.spa.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/42118 |
dc.identifier.eprints.spa.fl_str_mv |
http://bdigital.unal.edu.co/32215/ |
url |
https://repositorio.unal.edu.co/handle/unal/42118 http://bdigital.unal.edu.co/32215/ |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.spa.fl_str_mv |
http://revistas.unal.edu.co/index.php/dyna/article/view/31681 |
dc.relation.ispartof.spa.fl_str_mv |
Universidad Nacional de Colombia Revistas electrónicas UN Dyna Dyna |
dc.relation.ispartofseries.none.fl_str_mv |
Dyna; Vol. 80, núm. 182 (2013); 131-137 DYNA; Vol. 80, núm. 182 (2013); 131-137 2346-2183 0012-7353 |
dc.relation.references.spa.fl_str_mv |
González, Roberto and Quintana Hernández, María José and Ruiz Bustinza, Íñigo and García Carcelo, Fernando and Barbés, Miguel Ángel and Florentina Barbés, María (2013) Cooling efficiency in furnace design. Dyna; Vol. 80, núm. 182 (2013); 131-137 DYNA; Vol. 80, núm. 182 (2013); 131-137 2346-2183 0012-7353 . |
dc.rights.spa.fl_str_mv |
Derechos reservados - Universidad Nacional de Colombia |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial 4.0 Internacional Derechos reservados - Universidad Nacional de Colombia http://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Universidad Nacional de Colombia Sede Medellín |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/42118/1/31681-188334-1-PB.pdf https://repositorio.unal.edu.co/bitstream/unal/42118/2/31681-188334-1-PB.pdf.jpg |
bitstream.checksum.fl_str_mv |
b48dfc2a45f8709054bc406722930c14 7559b6622609f4f6c63d1ffe9f58f417 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814089851287371776 |