New methodology to diagnose reliability of a single distribution circuit in Colombia
A reliable electric power supply is of ever increasing importance in the Colombian electricity market. As such, the Energy and Gas Regulation Commission, (CREG for its acronym in Spanish), has contracted technical studies to be undertaken in order to assess reliability for Colombian electric utiliti...
- Autores:
-
Echeverry-Herrera, Jorge Alberto
Lozano-Moncada, Carlos Arturo
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2017
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/60382
- Acceso en línea:
- https://repositorio.unal.edu.co/handle/unal/60382
http://bdigital.unal.edu.co/58714/
- Palabra clave:
- 62 Ingeniería y operaciones afines / Engineering
Assess reliability
Colombian electric utilities
methodology
diagnose the reliability
single distribution circuit
reliability indexes
causes of failure
files
applications
Microsoft Excel
EMCALI EICE ESP
case study
ETAP software
Evaluar la confiabilidad
empresas del sector eléctrico colombiano
metodología
diagnosticar la confiabilidad
circuito individual de distribución
índices de confiabilidad
causas de falla
archivos
aplicaciones
Microsoft Excel
EMCALI EICE ESP
caso
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional
id |
UNACIONAL2_942a1fecc845c6ee8c0a524e5c5205b2 |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/60382 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
dc.title.spa.fl_str_mv |
New methodology to diagnose reliability of a single distribution circuit in Colombia |
title |
New methodology to diagnose reliability of a single distribution circuit in Colombia |
spellingShingle |
New methodology to diagnose reliability of a single distribution circuit in Colombia 62 Ingeniería y operaciones afines / Engineering Assess reliability Colombian electric utilities methodology diagnose the reliability single distribution circuit reliability indexes causes of failure files applications Microsoft Excel EMCALI EICE ESP case study ETAP software Evaluar la confiabilidad empresas del sector eléctrico colombiano metodología diagnosticar la confiabilidad circuito individual de distribución índices de confiabilidad causas de falla archivos aplicaciones Microsoft Excel EMCALI EICE ESP caso |
title_short |
New methodology to diagnose reliability of a single distribution circuit in Colombia |
title_full |
New methodology to diagnose reliability of a single distribution circuit in Colombia |
title_fullStr |
New methodology to diagnose reliability of a single distribution circuit in Colombia |
title_full_unstemmed |
New methodology to diagnose reliability of a single distribution circuit in Colombia |
title_sort |
New methodology to diagnose reliability of a single distribution circuit in Colombia |
dc.creator.fl_str_mv |
Echeverry-Herrera, Jorge Alberto Lozano-Moncada, Carlos Arturo |
dc.contributor.author.spa.fl_str_mv |
Echeverry-Herrera, Jorge Alberto Lozano-Moncada, Carlos Arturo |
dc.subject.ddc.spa.fl_str_mv |
62 Ingeniería y operaciones afines / Engineering |
topic |
62 Ingeniería y operaciones afines / Engineering Assess reliability Colombian electric utilities methodology diagnose the reliability single distribution circuit reliability indexes causes of failure files applications Microsoft Excel EMCALI EICE ESP case study ETAP software Evaluar la confiabilidad empresas del sector eléctrico colombiano metodología diagnosticar la confiabilidad circuito individual de distribución índices de confiabilidad causas de falla archivos aplicaciones Microsoft Excel EMCALI EICE ESP caso |
dc.subject.proposal.spa.fl_str_mv |
Assess reliability Colombian electric utilities methodology diagnose the reliability single distribution circuit reliability indexes causes of failure files applications Microsoft Excel EMCALI EICE ESP case study ETAP software Evaluar la confiabilidad empresas del sector eléctrico colombiano metodología diagnosticar la confiabilidad circuito individual de distribución índices de confiabilidad causas de falla archivos aplicaciones Microsoft Excel EMCALI EICE ESP caso |
description |
A reliable electric power supply is of ever increasing importance in the Colombian electricity market. As such, the Energy and Gas Regulation Commission, (CREG for its acronym in Spanish), has contracted technical studies to be undertaken in order to assess reliability for Colombian electric utilities. This paper focuses on a new methodology to diagnose the reliability of a single distribution circuit that is to be used in Colombian electric utilities. The proposed methodology includes calculating known reliability indexes (SAIFI, SAIDI, CAIDI, etc.) as well as new reliability indexes in order to determine the incidence of causes of failure. This paper explains some of the required files´ characteristics (input and output files) in order to execute two applications associated with the previously mentioned methodology. These two applications were developed using Microsoft Excel for the Strategic Energy Business Unit at EMCALI EICE ESP, located on Santiago de Cali, Valle del Cauca, Colombia, South America. This article describes some features of these applications. The first case study presented, about the first application, is calculated based on this methodology, and results obtained are compared with those obtained using ETAP software. Finally, the second case study, regarding the second application, is calculated based on this methodology and results obtained are shown in this document. |
publishDate |
2017 |
dc.date.issued.spa.fl_str_mv |
2017-04-01 |
dc.date.accessioned.spa.fl_str_mv |
2019-07-02T18:11:25Z |
dc.date.available.spa.fl_str_mv |
2019-07-02T18:11:25Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.coarversion.spa.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.issn.spa.fl_str_mv |
ISSN: 2346-2183 |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/60382 |
dc.identifier.eprints.spa.fl_str_mv |
http://bdigital.unal.edu.co/58714/ |
identifier_str_mv |
ISSN: 2346-2183 |
url |
https://repositorio.unal.edu.co/handle/unal/60382 http://bdigital.unal.edu.co/58714/ |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.spa.fl_str_mv |
https://revistas.unal.edu.co/index.php/dyna/article/view/54330 |
dc.relation.ispartof.spa.fl_str_mv |
Universidad Nacional de Colombia Revistas electrónicas UN Dyna Dyna |
dc.relation.references.spa.fl_str_mv |
Echeverry-Herrera, Jorge Alberto and Lozano-Moncada, Carlos Arturo (2017) New methodology to diagnose reliability of a single distribution circuit in Colombia. DYNA, 84 (201). pp. 74-81. ISSN 2346-2183 |
dc.rights.spa.fl_str_mv |
Derechos reservados - Universidad Nacional de Colombia |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial 4.0 Internacional Derechos reservados - Universidad Nacional de Colombia http://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Universidad Nacional de Colombia (Sede Medellín). Facultad de Minas. |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/60382/1/54330-330576-2-PB.pdf https://repositorio.unal.edu.co/bitstream/unal/60382/2/54330-330576-2-PB.pdf.jpg |
bitstream.checksum.fl_str_mv |
9df57b2b0d3e56516cc1767ade74d9d7 a2f5539721def386cd1ba3ec4e84a0f6 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814090189318914048 |
spelling |
Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Echeverry-Herrera, Jorge Alberto45c1f68d-b8db-4da8-8a85-02acf42e62d1300Lozano-Moncada, Carlos Arturoae63e97c-b6d1-4d02-a53c-f3ef13789d363002019-07-02T18:11:25Z2019-07-02T18:11:25Z2017-04-01ISSN: 2346-2183https://repositorio.unal.edu.co/handle/unal/60382http://bdigital.unal.edu.co/58714/A reliable electric power supply is of ever increasing importance in the Colombian electricity market. As such, the Energy and Gas Regulation Commission, (CREG for its acronym in Spanish), has contracted technical studies to be undertaken in order to assess reliability for Colombian electric utilities. This paper focuses on a new methodology to diagnose the reliability of a single distribution circuit that is to be used in Colombian electric utilities. The proposed methodology includes calculating known reliability indexes (SAIFI, SAIDI, CAIDI, etc.) as well as new reliability indexes in order to determine the incidence of causes of failure. This paper explains some of the required files´ characteristics (input and output files) in order to execute two applications associated with the previously mentioned methodology. These two applications were developed using Microsoft Excel for the Strategic Energy Business Unit at EMCALI EICE ESP, located on Santiago de Cali, Valle del Cauca, Colombia, South America. This article describes some features of these applications. The first case study presented, about the first application, is calculated based on this methodology, and results obtained are compared with those obtained using ETAP software. Finally, the second case study, regarding the second application, is calculated based on this methodology and results obtained are shown in this document.El suministro confiable de energía eléctrica es cada vez más importante en el mercado eléctrico colombiano. De esta manera, la Comisión de Regulación de Energía y Gas, (CREG por su sigla en español), ha contratado estudios técnicos a ser llevados a cabo a fin de evaluar la confiabilidad de las empresas del sector eléctrico colombiano. Este trabajo se enfoca en una nueva metodología para diagnosticar la confiabilidad de un circuito individual de distribución a ser utilizado en las empresas del sector eléctrico colombiano. La metodología propuesta incluye el cálculo de índices de confiabilidad conocidos (SAIFI, SAIDI, CAIDI, etc.), así como nuevos índices de confiabilidad con el fin de determinar la incidencia de las causas de falla. Este documento explica algunas características de los archivos requeridos (archivos de entrada y salida) con el fin de ejecutar dos aplicaciones asociadas con la metodología mencionada anteriormente. Estas dos aplicaciones fueron desarrolladas utilizando Microsoft Excel para la Unidad Estratégica de Negocio de Energía de EMCALI EICE ESP, localizada en Santiago de Cali, Valle del Cauca, Colombia, Sudamérica. Este artículo describe algunas características de estas aplicaciones. El primer caso de estudio presentado, sobre la primera aplicación, se calcula sobre la base de esta metodología y los resultados obtenidos se comparan con aquellos obtenidos utilizando el software ETAP. Por último, el segundo caso de estudio, con respecto a la segunda aplicación, se calcula sobre la base de esta metodología y los resultados obtenidos se muestran en este documento.application/pdfspaUniversidad Nacional de Colombia (Sede Medellín). Facultad de Minas.https://revistas.unal.edu.co/index.php/dyna/article/view/54330Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaEcheverry-Herrera, Jorge Alberto and Lozano-Moncada, Carlos Arturo (2017) New methodology to diagnose reliability of a single distribution circuit in Colombia. DYNA, 84 (201). pp. 74-81. ISSN 2346-218362 Ingeniería y operaciones afines / EngineeringAssess reliabilityColombian electric utilitiesmethodologydiagnose the reliabilitysingle distribution circuitreliability indexescauses of failurefilesapplicationsMicrosoft ExcelEMCALI EICE ESPcase studyETAP softwareEvaluar la confiabilidadempresas del sector eléctrico colombianometodologíadiagnosticar la confiabilidadcircuito individual de distribucióníndices de confiabilidadcausas de fallaarchivosaplicacionesMicrosoft ExcelEMCALI EICE ESPcasoNew methodology to diagnose reliability of a single distribution circuit in ColombiaArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL54330-330576-2-PB.pdfapplication/pdf703719https://repositorio.unal.edu.co/bitstream/unal/60382/1/54330-330576-2-PB.pdf9df57b2b0d3e56516cc1767ade74d9d7MD51THUMBNAIL54330-330576-2-PB.pdf.jpg54330-330576-2-PB.pdf.jpgGenerated Thumbnailimage/jpeg9074https://repositorio.unal.edu.co/bitstream/unal/60382/2/54330-330576-2-PB.pdf.jpga2f5539721def386cd1ba3ec4e84a0f6MD52unal/60382oai:repositorio.unal.edu.co:unal/603822023-04-06 23:05:48.834Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co |