Effect of amplitude and pulse in low frequency ultrasound on oil/water emulsions

The application of ultrasound within advanced or emerging technologies requires selecting parameters that depend on the target application. This study evaluated pulse and amplitude parameters of oil/water emulsions (20:80% w/w) using low frequency probe ultrasound equipment (20 KHz). A categorical m...

Full description

Autores:
Cabrera-Trujillo, María Alejandra
Sotelo-Díaz, Luz Indira
Quintanilla-Carvajal, María Ximena
Tipo de recurso:
Article of journal
Fecha de publicación:
2016
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/60482
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/60482
http://bdigital.unal.edu.co/58814/
Palabra clave:
62 Ingeniería y operaciones afines / Engineering
Ultrasound probe
low frequency
emulsion
pulse
amplitude
phase separation
Sonda de ultrasonido
baja frecuencia
emulsión
pulsación
amplitud
separación de fases
Rights
openAccess
License
Atribución-NoComercial 4.0 Internacional
id UNACIONAL2_940f4f19342ec58cc0dbc9556742ea58
oai_identifier_str oai:repositorio.unal.edu.co:unal/60482
network_acronym_str UNACIONAL2
network_name_str Universidad Nacional de Colombia
repository_id_str
spelling Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Cabrera-Trujillo, María Alejandraf2f4d003-352c-46b1-b2c6-2fb3a7768a5b300Sotelo-Díaz, Luz Indira08e5bf02-eff9-4ed6-867d-52ab3f791b76300Quintanilla-Carvajal, María Ximena83d1578a-ca1e-4931-86c3-8f83fb897a823002019-07-02T18:25:16Z2019-07-02T18:25:16Z2016-10-01ISSN: 2346-2183https://repositorio.unal.edu.co/handle/unal/60482http://bdigital.unal.edu.co/58814/The application of ultrasound within advanced or emerging technologies requires selecting parameters that depend on the target application. This study evaluated pulse and amplitude parameters of oil/water emulsions (20:80% w/w) using low frequency probe ultrasound equipment (20 KHz). A categorical multilevel factorial design was used with Design Expert® in which the following pulse treatments were defined: continuous, pulse 20:20 (on:off) and pulse 30:30 (on:off), for five minutes. Six amplitudes (30, 36, 42, 48, 54 and 60 μm) were evaluated for the following response variables: separation of phases in emulsion, temperature and accumulated power. The results showed that the best condition to obtain an emulsion with less phase separation was the 20:20 (on:off) treatment with an amplitude of 42 μm. The ultrasound probe application parameters that were obtained will enable the design of stable products from low-fat emulsions.La aplicación de ultrasonido dentro del concepto de tecnologías avanzadas o emergentes, requiere de la selección de parámetros según sea el objetivo de su aplicación. En esta investigación fueron evaluados parámetros de pulsación y amplitud para mezclas aceite/agua (20:80 % p/p), empleando un equipo de ultrasonido de sonda de baja frecuencia (20KHz). Los tratamientos de pulsación utilizados fueron: continuo, pulsación 20:20 (on:off) y pulsación 30:30 (on:off) durante cinco minutos; se evaluaron seis amplitudes (30, 36, 42, 48, 54 y 60 μm) sobre las variables de respuesta: separación de fases en la mezcla, temperatura y potencia acumulada. Los resultados obtenidos analizados por Design Expert® por medio de un diseño factorial multinivel categórico mostraron que la mejor condición para obtener una mezcla con menor separación, fue el tratamiento 20:20 (on:off), con una amplitud de 42 μm.Lo anterior evidencia el uso de ultrasonido de sonda como una metodología potencial para la homogenización de mezclas.application/pdfspaUniversidad Nacional de Colombia (Sede Medellín). Facultad de Minas.https://revistas.unal.edu.co/index.php/dyna/article/view/56192Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaCabrera-Trujillo, María Alejandra and Sotelo-Díaz, Luz Indira and Quintanilla-Carvajal, María Ximena (2016) Effect of amplitude and pulse in low frequency ultrasound on oil/water emulsions. DYNA, 83 (199). pp. 63-68. ISSN 2346-218362 Ingeniería y operaciones afines / EngineeringUltrasound probelow frequencyemulsionpulseamplitudephase separationSonda de ultrasonidobaja frecuenciaemulsiónpulsaciónamplitudseparación de fasesEffect of amplitude and pulse in low frequency ultrasound on oil/water emulsionsArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL56192-309939-1-PB.pdfapplication/pdf420935https://repositorio.unal.edu.co/bitstream/unal/60482/1/56192-309939-1-PB.pdf67df08a51a0f10e2be8589f82fcc2685MD51THUMBNAIL56192-309939-1-PB.pdf.jpg56192-309939-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg9776https://repositorio.unal.edu.co/bitstream/unal/60482/2/56192-309939-1-PB.pdf.jpg1a826f1aba43789939de967a15ff4bf7MD52unal/60482oai:repositorio.unal.edu.co:unal/604822023-04-07 23:04:30.695Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co
dc.title.spa.fl_str_mv Effect of amplitude and pulse in low frequency ultrasound on oil/water emulsions
title Effect of amplitude and pulse in low frequency ultrasound on oil/water emulsions
spellingShingle Effect of amplitude and pulse in low frequency ultrasound on oil/water emulsions
62 Ingeniería y operaciones afines / Engineering
Ultrasound probe
low frequency
emulsion
pulse
amplitude
phase separation
Sonda de ultrasonido
baja frecuencia
emulsión
pulsación
amplitud
separación de fases
title_short Effect of amplitude and pulse in low frequency ultrasound on oil/water emulsions
title_full Effect of amplitude and pulse in low frequency ultrasound on oil/water emulsions
title_fullStr Effect of amplitude and pulse in low frequency ultrasound on oil/water emulsions
title_full_unstemmed Effect of amplitude and pulse in low frequency ultrasound on oil/water emulsions
title_sort Effect of amplitude and pulse in low frequency ultrasound on oil/water emulsions
dc.creator.fl_str_mv Cabrera-Trujillo, María Alejandra
Sotelo-Díaz, Luz Indira
Quintanilla-Carvajal, María Ximena
dc.contributor.author.spa.fl_str_mv Cabrera-Trujillo, María Alejandra
Sotelo-Díaz, Luz Indira
Quintanilla-Carvajal, María Ximena
dc.subject.ddc.spa.fl_str_mv 62 Ingeniería y operaciones afines / Engineering
topic 62 Ingeniería y operaciones afines / Engineering
Ultrasound probe
low frequency
emulsion
pulse
amplitude
phase separation
Sonda de ultrasonido
baja frecuencia
emulsión
pulsación
amplitud
separación de fases
dc.subject.proposal.spa.fl_str_mv Ultrasound probe
low frequency
emulsion
pulse
amplitude
phase separation
Sonda de ultrasonido
baja frecuencia
emulsión
pulsación
amplitud
separación de fases
description The application of ultrasound within advanced or emerging technologies requires selecting parameters that depend on the target application. This study evaluated pulse and amplitude parameters of oil/water emulsions (20:80% w/w) using low frequency probe ultrasound equipment (20 KHz). A categorical multilevel factorial design was used with Design Expert® in which the following pulse treatments were defined: continuous, pulse 20:20 (on:off) and pulse 30:30 (on:off), for five minutes. Six amplitudes (30, 36, 42, 48, 54 and 60 μm) were evaluated for the following response variables: separation of phases in emulsion, temperature and accumulated power. The results showed that the best condition to obtain an emulsion with less phase separation was the 20:20 (on:off) treatment with an amplitude of 42 μm. The ultrasound probe application parameters that were obtained will enable the design of stable products from low-fat emulsions.
publishDate 2016
dc.date.issued.spa.fl_str_mv 2016-10-01
dc.date.accessioned.spa.fl_str_mv 2019-07-02T18:25:16Z
dc.date.available.spa.fl_str_mv 2019-07-02T18:25:16Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.issn.spa.fl_str_mv ISSN: 2346-2183
dc.identifier.uri.none.fl_str_mv https://repositorio.unal.edu.co/handle/unal/60482
dc.identifier.eprints.spa.fl_str_mv http://bdigital.unal.edu.co/58814/
identifier_str_mv ISSN: 2346-2183
url https://repositorio.unal.edu.co/handle/unal/60482
http://bdigital.unal.edu.co/58814/
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv https://revistas.unal.edu.co/index.php/dyna/article/view/56192
dc.relation.ispartof.spa.fl_str_mv Universidad Nacional de Colombia Revistas electrónicas UN Dyna
Dyna
dc.relation.references.spa.fl_str_mv Cabrera-Trujillo, María Alejandra and Sotelo-Díaz, Luz Indira and Quintanilla-Carvajal, María Ximena (2016) Effect of amplitude and pulse in low frequency ultrasound on oil/water emulsions. DYNA, 83 (199). pp. 63-68. ISSN 2346-2183
dc.rights.spa.fl_str_mv Derechos reservados - Universidad Nacional de Colombia
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.license.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional
dc.rights.uri.spa.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv Atribución-NoComercial 4.0 Internacional
Derechos reservados - Universidad Nacional de Colombia
http://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Nacional de Colombia (Sede Medellín). Facultad de Minas.
institution Universidad Nacional de Colombia
bitstream.url.fl_str_mv https://repositorio.unal.edu.co/bitstream/unal/60482/1/56192-309939-1-PB.pdf
https://repositorio.unal.edu.co/bitstream/unal/60482/2/56192-309939-1-PB.pdf.jpg
bitstream.checksum.fl_str_mv 67df08a51a0f10e2be8589f82fcc2685
1a826f1aba43789939de967a15ff4bf7
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad Nacional de Colombia
repository.mail.fl_str_mv repositorio_nal@unal.edu.co
_version_ 1814089431524573184