Stability study in the performance of sensors and biosensors based on conductor polymers in strong acidic media
Developing and constructing the mathematical model (applying the linear stability theory and bifurcation analysis), the electrochemical behavior, observed during the work of the CP-based electrochemical sensors and biosensors in strongly acid solution, was investigated. The conditions for the steady...
- Autores:
-
Valentynovych Tkach, Volodymyr
Vasyl´ovych Nechyporuk, Vasyl´
Ivanonych Yagodynets´, Petro
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2013
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/49543
- Acceso en línea:
- https://repositorio.unal.edu.co/handle/unal/49543
http://bdigital.unal.edu.co/43010/
http://bdigital.unal.edu.co/43010/2/
- Palabra clave:
- polímeros conductores
sensores y biosensores electroquímicos
potencial de hidrógeno
oscilaciones electroquímicas
estado estacionario estable
conducting polymers
electrochemical sensors and biosensors
hydrogen potential
electrochemical oscillations
stable steady-state
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional
id |
UNACIONAL2_931ba8992a58bb5f036ca4a823ef0855 |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/49543 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
spelling |
Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Valentynovych Tkach, Volodymyr0af06e9e-3416-4e57-9a4b-a7823148c985300Vasyl´ovych Nechyporuk, Vasyl´f109bb18-0591-4e2d-937c-3a1d581844fb300Ivanonych Yagodynets´, Petro0c3f3c3b-3222-49ca-80ab-8ae7187a9f7b3002019-06-29T08:54:30Z2019-06-29T08:54:30Z2013https://repositorio.unal.edu.co/handle/unal/49543http://bdigital.unal.edu.co/43010/http://bdigital.unal.edu.co/43010/2/Developing and constructing the mathematical model (applying the linear stability theory and bifurcation analysis), the electrochemical behavior, observed during the work of the CP-based electrochemical sensors and biosensors in strongly acid solution, was investigated. The conditions for the steady-state stability and oscillatory and monotonic instabilities were derived for the work of the biosensor in potentiostatic mode. The results of the analysis for the case of strongly acid solution were compared to the previously obtained for the case of neutral and basic solution and in such way it's possible to make conclusions about the influence of pH on the functioning of sensors and biosensors.Por medio del desarrollo del modelo matemático y su análisis (aplicándose la teoría de estabilidad lineal y el análisis de bifurcaciones) se investigó el comportamiento electroquímico, observado en el caso del desempeño de los sensores y biosensores electroquímicos basados en los polímeros conductores en una solución altamente ácida. Fueron derivadas las condiciones de estabilidad del estado estacionario; de las inestabilidades oscilatorias y monotónicas para el desempeño del biosensor en modo de potencia estática. Los resultados del análisis para el caso del medio fuertemente ácido se compararon con los anteriormente obtenidos para el de la solución neutral y básica; por lo cual, así pudo ser inferida la conclusión sobre la influencia del pH al funcionamiento de los sensores y biosensores electroquímicos.application/pdfspaRevista Colombiana de Ciencias Químico Farmacéuticashttp://revistas.unal.edu.co/index.php/rccquifa/article/view/45101Universidad Nacional de Colombia Revistas electrónicas UN Revista Colombiana de Ciencias Químico FarmacéuticasRevista Colombiana de Ciencias Químico FarmacéuticasRevista Colombiana de Ciencias Químico Farmacéuticas; Vol. 42, núm. 1 (2013); 30-41 0034-7418 1909-6356Valentynovych Tkach, Volodymyr and Vasyl´ovych Nechyporuk, Vasyl´ and Ivanonych Yagodynets´, Petro (2013) Stability study in the performance of sensors and biosensors based on conductor polymers in strong acidic media. Revista Colombiana de Ciencias Químico Farmacéuticas; Vol. 42, núm. 1 (2013); 30-41 0034-7418 1909-6356 .Stability study in the performance of sensors and biosensors based on conductor polymers in strong acidic mediaArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTpolímeros conductoressensores y biosensores electroquímicospotencial de hidrógenooscilaciones electroquímicasestado estacionario estableconducting polymerselectrochemical sensors and biosensorshydrogen potentialelectrochemical oscillationsstable steady-stateORIGINAL45101-216306-1-SM.pdfapplication/pdf129095https://repositorio.unal.edu.co/bitstream/unal/49543/1/45101-216306-1-SM.pdfae05d6a4812a3887520cb05630d0626dMD51THUMBNAIL45101-216306-1-SM.pdf.jpg45101-216306-1-SM.pdf.jpgGenerated Thumbnailimage/jpeg5338https://repositorio.unal.edu.co/bitstream/unal/49543/2/45101-216306-1-SM.pdf.jpg7318c461910125db5dc58fe100391c3aMD52unal/49543oai:repositorio.unal.edu.co:unal/495432022-12-15 23:08:28.02Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co |
dc.title.spa.fl_str_mv |
Stability study in the performance of sensors and biosensors based on conductor polymers in strong acidic media |
title |
Stability study in the performance of sensors and biosensors based on conductor polymers in strong acidic media |
spellingShingle |
Stability study in the performance of sensors and biosensors based on conductor polymers in strong acidic media polímeros conductores sensores y biosensores electroquímicos potencial de hidrógeno oscilaciones electroquímicas estado estacionario estable conducting polymers electrochemical sensors and biosensors hydrogen potential electrochemical oscillations stable steady-state |
title_short |
Stability study in the performance of sensors and biosensors based on conductor polymers in strong acidic media |
title_full |
Stability study in the performance of sensors and biosensors based on conductor polymers in strong acidic media |
title_fullStr |
Stability study in the performance of sensors and biosensors based on conductor polymers in strong acidic media |
title_full_unstemmed |
Stability study in the performance of sensors and biosensors based on conductor polymers in strong acidic media |
title_sort |
Stability study in the performance of sensors and biosensors based on conductor polymers in strong acidic media |
dc.creator.fl_str_mv |
Valentynovych Tkach, Volodymyr Vasyl´ovych Nechyporuk, Vasyl´ Ivanonych Yagodynets´, Petro |
dc.contributor.author.spa.fl_str_mv |
Valentynovych Tkach, Volodymyr Vasyl´ovych Nechyporuk, Vasyl´ Ivanonych Yagodynets´, Petro |
dc.subject.proposal.spa.fl_str_mv |
polímeros conductores sensores y biosensores electroquímicos potencial de hidrógeno oscilaciones electroquímicas estado estacionario estable conducting polymers electrochemical sensors and biosensors hydrogen potential electrochemical oscillations stable steady-state |
topic |
polímeros conductores sensores y biosensores electroquímicos potencial de hidrógeno oscilaciones electroquímicas estado estacionario estable conducting polymers electrochemical sensors and biosensors hydrogen potential electrochemical oscillations stable steady-state |
description |
Developing and constructing the mathematical model (applying the linear stability theory and bifurcation analysis), the electrochemical behavior, observed during the work of the CP-based electrochemical sensors and biosensors in strongly acid solution, was investigated. The conditions for the steady-state stability and oscillatory and monotonic instabilities were derived for the work of the biosensor in potentiostatic mode. The results of the analysis for the case of strongly acid solution were compared to the previously obtained for the case of neutral and basic solution and in such way it's possible to make conclusions about the influence of pH on the functioning of sensors and biosensors. |
publishDate |
2013 |
dc.date.issued.spa.fl_str_mv |
2013 |
dc.date.accessioned.spa.fl_str_mv |
2019-06-29T08:54:30Z |
dc.date.available.spa.fl_str_mv |
2019-06-29T08:54:30Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.coarversion.spa.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/49543 |
dc.identifier.eprints.spa.fl_str_mv |
http://bdigital.unal.edu.co/43010/ http://bdigital.unal.edu.co/43010/2/ |
url |
https://repositorio.unal.edu.co/handle/unal/49543 http://bdigital.unal.edu.co/43010/ http://bdigital.unal.edu.co/43010/2/ |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.spa.fl_str_mv |
http://revistas.unal.edu.co/index.php/rccquifa/article/view/45101 |
dc.relation.ispartof.spa.fl_str_mv |
Universidad Nacional de Colombia Revistas electrónicas UN Revista Colombiana de Ciencias Químico Farmacéuticas Revista Colombiana de Ciencias Químico Farmacéuticas |
dc.relation.ispartofseries.none.fl_str_mv |
Revista Colombiana de Ciencias Químico Farmacéuticas; Vol. 42, núm. 1 (2013); 30-41 0034-7418 1909-6356 |
dc.relation.references.spa.fl_str_mv |
Valentynovych Tkach, Volodymyr and Vasyl´ovych Nechyporuk, Vasyl´ and Ivanonych Yagodynets´, Petro (2013) Stability study in the performance of sensors and biosensors based on conductor polymers in strong acidic media. Revista Colombiana de Ciencias Químico Farmacéuticas; Vol. 42, núm. 1 (2013); 30-41 0034-7418 1909-6356 . |
dc.rights.spa.fl_str_mv |
Derechos reservados - Universidad Nacional de Colombia |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial 4.0 Internacional Derechos reservados - Universidad Nacional de Colombia http://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Revista Colombiana de Ciencias Químico Farmacéuticas |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/49543/1/45101-216306-1-SM.pdf https://repositorio.unal.edu.co/bitstream/unal/49543/2/45101-216306-1-SM.pdf.jpg |
bitstream.checksum.fl_str_mv |
ae05d6a4812a3887520cb05630d0626d 7318c461910125db5dc58fe100391c3a |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814089710583152640 |