Complete power distribution system representation and state determination for fault location
The impedance-based approaches for fault location in power distribution systems determine a faulted line section. Next, these require of the estimation of the voltages and currents at one or both section line ends to exactly determine the fault location. It is a challenge because in most of the powe...
- Autores:
-
Panesso Hernández, Andrés Felipe
Mora Flórez, Juan José
Pérez-Londoño, Sandra Milena
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2015
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/60692
- Acceso en línea:
- https://repositorio.unal.edu.co/handle/unal/60692
http://bdigital.unal.edu.co/59024/
- Palabra clave:
- 62 Ingeniería y operaciones afines / Engineering
Fault location
forward sweep-based method
modeling
power distribution systems
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional
id |
UNACIONAL2_8be27b64f9ed3dad31fbe130be4ce8dd |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/60692 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
spelling |
Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Panesso Hernández, Andrés Felipee5f909d1-3271-48e9-802f-f536bbe6351e300Mora Flórez, Juan José2aa86417-c5c7-47b1-b6b1-78b923702e15300Pérez-Londoño, Sandra Milena5aa5d86a-abd7-47b0-9416-400d8ee7db973002019-07-02T18:53:51Z2019-07-02T18:53:51Z2015-07-01ISSN: 2346-2183https://repositorio.unal.edu.co/handle/unal/60692http://bdigital.unal.edu.co/59024/The impedance-based approaches for fault location in power distribution systems determine a faulted line section. Next, these require of the estimation of the voltages and currents at one or both section line ends to exactly determine the fault location. It is a challenge because in most of the power distribution systems, measurements are only available at the main substation. This document presents a modeling proposal of the power distribution system and an easy implementation method to estimate the voltages and currents at the faulted line section, using the measurements at the main substation, the line, load, transformer parameters and other serial and shunt connected devices and the power system topology. The approach here proposed is tested using a fault locator based on superimposed components, where the distance estimation error is lower than 1.5% in all of the cases.application/pdfspaUniversidad Nacional de Colombia (Sede Medellín). Facultad de Minas.https://revistas.unal.edu.co/index.php/dyna/article/view/48589Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaPanesso Hernández, Andrés Felipe and Mora Flórez, Juan José and Pérez Londoño, Sandra Milena (2015) Complete power distribution system representation and state determination for fault location. DYNA, 82 (192). pp. 141-149. ISSN 2346-218362 Ingeniería y operaciones afines / EngineeringFault locationforward sweep-based methodmodelingpower distribution systemsComplete power distribution system representation and state determination for fault locationArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL48589-257569-1-PB.pdfapplication/pdf1046190https://repositorio.unal.edu.co/bitstream/unal/60692/1/48589-257569-1-PB.pdf64a5eb7dfec58b690f0d2625520dcfddMD51THUMBNAIL48589-257569-1-PB.pdf.jpg48589-257569-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg9206https://repositorio.unal.edu.co/bitstream/unal/60692/2/48589-257569-1-PB.pdf.jpgf8344d9276046e1e86e064e294121c7bMD52unal/60692oai:repositorio.unal.edu.co:unal/606922024-04-14 23:11:33.916Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co |
dc.title.spa.fl_str_mv |
Complete power distribution system representation and state determination for fault location |
title |
Complete power distribution system representation and state determination for fault location |
spellingShingle |
Complete power distribution system representation and state determination for fault location 62 Ingeniería y operaciones afines / Engineering Fault location forward sweep-based method modeling power distribution systems |
title_short |
Complete power distribution system representation and state determination for fault location |
title_full |
Complete power distribution system representation and state determination for fault location |
title_fullStr |
Complete power distribution system representation and state determination for fault location |
title_full_unstemmed |
Complete power distribution system representation and state determination for fault location |
title_sort |
Complete power distribution system representation and state determination for fault location |
dc.creator.fl_str_mv |
Panesso Hernández, Andrés Felipe Mora Flórez, Juan José Pérez-Londoño, Sandra Milena |
dc.contributor.author.spa.fl_str_mv |
Panesso Hernández, Andrés Felipe Mora Flórez, Juan José Pérez-Londoño, Sandra Milena |
dc.subject.ddc.spa.fl_str_mv |
62 Ingeniería y operaciones afines / Engineering |
topic |
62 Ingeniería y operaciones afines / Engineering Fault location forward sweep-based method modeling power distribution systems |
dc.subject.proposal.spa.fl_str_mv |
Fault location forward sweep-based method modeling power distribution systems |
description |
The impedance-based approaches for fault location in power distribution systems determine a faulted line section. Next, these require of the estimation of the voltages and currents at one or both section line ends to exactly determine the fault location. It is a challenge because in most of the power distribution systems, measurements are only available at the main substation. This document presents a modeling proposal of the power distribution system and an easy implementation method to estimate the voltages and currents at the faulted line section, using the measurements at the main substation, the line, load, transformer parameters and other serial and shunt connected devices and the power system topology. The approach here proposed is tested using a fault locator based on superimposed components, where the distance estimation error is lower than 1.5% in all of the cases. |
publishDate |
2015 |
dc.date.issued.spa.fl_str_mv |
2015-07-01 |
dc.date.accessioned.spa.fl_str_mv |
2019-07-02T18:53:51Z |
dc.date.available.spa.fl_str_mv |
2019-07-02T18:53:51Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.coarversion.spa.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.issn.spa.fl_str_mv |
ISSN: 2346-2183 |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/60692 |
dc.identifier.eprints.spa.fl_str_mv |
http://bdigital.unal.edu.co/59024/ |
identifier_str_mv |
ISSN: 2346-2183 |
url |
https://repositorio.unal.edu.co/handle/unal/60692 http://bdigital.unal.edu.co/59024/ |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.spa.fl_str_mv |
https://revistas.unal.edu.co/index.php/dyna/article/view/48589 |
dc.relation.ispartof.spa.fl_str_mv |
Universidad Nacional de Colombia Revistas electrónicas UN Dyna Dyna |
dc.relation.references.spa.fl_str_mv |
Panesso Hernández, Andrés Felipe and Mora Flórez, Juan José and Pérez Londoño, Sandra Milena (2015) Complete power distribution system representation and state determination for fault location. DYNA, 82 (192). pp. 141-149. ISSN 2346-2183 |
dc.rights.spa.fl_str_mv |
Derechos reservados - Universidad Nacional de Colombia |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial 4.0 Internacional Derechos reservados - Universidad Nacional de Colombia http://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Universidad Nacional de Colombia (Sede Medellín). Facultad de Minas. |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/60692/1/48589-257569-1-PB.pdf https://repositorio.unal.edu.co/bitstream/unal/60692/2/48589-257569-1-PB.pdf.jpg |
bitstream.checksum.fl_str_mv |
64a5eb7dfec58b690f0d2625520dcfdd f8344d9276046e1e86e064e294121c7b |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814089524647559168 |