Ultrasonic sensor for the presence of oily contaminants in water

The measurement of the reflection coefficient of ultrasonic shear-waves at the solid-liquid interface is a technique employed for the measurement of the viscoelastic properties of liquids. An interesting property of the measurement technique is the very small penetration depth of the shear-waves int...

Full description

Autores:
Franco, Ediguer Enrique
Adamowski, Julio Cezar
Buiochi, Flávio
Tipo de recurso:
Article of journal
Fecha de publicación:
2012
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/35070
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/35070
http://bdigital.unal.edu.co/25150/
Palabra clave:
Ultrasound
shear waves
oil-in-water emulsion
oily contaminant
Rights
openAccess
License
Atribución-NoComercial 4.0 Internacional
id UNACIONAL2_85d72afcbd8af5660c413f89c5ea6363
oai_identifier_str oai:repositorio.unal.edu.co:unal/35070
network_acronym_str UNACIONAL2
network_name_str Universidad Nacional de Colombia
repository_id_str
spelling Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Franco, Ediguer Enrique4ed89860-97d7-4b2e-9782-dd40931138e6300Adamowski, Julio Cezared642d5b-b2dd-41c1-83e2-e4c005340fb1300Buiochi, Flávio4c52d938-5213-41ec-9338-7dd305e6467f3002019-06-27T23:53:59Z2019-06-27T23:53:59Z2012https://repositorio.unal.edu.co/handle/unal/35070http://bdigital.unal.edu.co/25150/The measurement of the reflection coefficient of ultrasonic shear-waves at the solid-liquid interface is a technique employed for the measurement of the viscoelastic properties of liquids. An interesting property of the measurement technique is the very small penetration depth of the shear-waves into the liquid sample, that permits measurements with liquid films of some micrometers thick. This property, besides the well known tendency of oily substances to stick to the surfaces, can be used for the detection of oily contaminants in water. In this work, the employment of the ultrasonic shear-wave reflection technique to the detection of oily contaminants in water is proposed and the theoretical and experimental concepts involved are discussed. Preliminary experimental results show the measurement technique can detect SAE 40 automotive oil in water in volume proportions less than 0.5%.application/pdfspaUniversidad Nacional de Colombia Sede Medellínhttp://revistas.unal.edu.co/index.php/dyna/article/view/22420Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaDyna; Vol. 79, núm. 176 (2012); 4-9 DYNA; Vol. 79, núm. 176 (2012); 4-9 2346-2183 0012-7353Franco, Ediguer Enrique and Adamowski, Julio Cezar and Buiochi, Flávio (2012) Ultrasonic sensor for the presence of oily contaminants in water. Dyna; Vol. 79, núm. 176 (2012); 4-9 DYNA; Vol. 79, núm. 176 (2012); 4-9 2346-2183 0012-7353 .Ultrasonic sensor for the presence of oily contaminants in waterArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTUltrasoundshear wavesoil-in-water emulsionoily contaminantORIGINAL22420-191444-1-PB.htmltext/html28602https://repositorio.unal.edu.co/bitstream/unal/35070/1/22420-191444-1-PB.htmlf3ef73d540e88514ebb2f2ec008027f0MD5122420-151091-1-PB.pdfapplication/pdf610213https://repositorio.unal.edu.co/bitstream/unal/35070/2/22420-151091-1-PB.pdfed513de3b5813f93ec19f38c04f30eb5MD52THUMBNAIL22420-151091-1-PB.pdf.jpg22420-151091-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg8807https://repositorio.unal.edu.co/bitstream/unal/35070/3/22420-151091-1-PB.pdf.jpg9f3cfc7c6846cfb5bfc223ec93dcc577MD53unal/35070oai:repositorio.unal.edu.co:unal/350702023-01-03 23:04:38.093Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co
dc.title.spa.fl_str_mv Ultrasonic sensor for the presence of oily contaminants in water
title Ultrasonic sensor for the presence of oily contaminants in water
spellingShingle Ultrasonic sensor for the presence of oily contaminants in water
Ultrasound
shear waves
oil-in-water emulsion
oily contaminant
title_short Ultrasonic sensor for the presence of oily contaminants in water
title_full Ultrasonic sensor for the presence of oily contaminants in water
title_fullStr Ultrasonic sensor for the presence of oily contaminants in water
title_full_unstemmed Ultrasonic sensor for the presence of oily contaminants in water
title_sort Ultrasonic sensor for the presence of oily contaminants in water
dc.creator.fl_str_mv Franco, Ediguer Enrique
Adamowski, Julio Cezar
Buiochi, Flávio
dc.contributor.author.spa.fl_str_mv Franco, Ediguer Enrique
Adamowski, Julio Cezar
Buiochi, Flávio
dc.subject.proposal.spa.fl_str_mv Ultrasound
shear waves
oil-in-water emulsion
oily contaminant
topic Ultrasound
shear waves
oil-in-water emulsion
oily contaminant
description The measurement of the reflection coefficient of ultrasonic shear-waves at the solid-liquid interface is a technique employed for the measurement of the viscoelastic properties of liquids. An interesting property of the measurement technique is the very small penetration depth of the shear-waves into the liquid sample, that permits measurements with liquid films of some micrometers thick. This property, besides the well known tendency of oily substances to stick to the surfaces, can be used for the detection of oily contaminants in water. In this work, the employment of the ultrasonic shear-wave reflection technique to the detection of oily contaminants in water is proposed and the theoretical and experimental concepts involved are discussed. Preliminary experimental results show the measurement technique can detect SAE 40 automotive oil in water in volume proportions less than 0.5%.
publishDate 2012
dc.date.issued.spa.fl_str_mv 2012
dc.date.accessioned.spa.fl_str_mv 2019-06-27T23:53:59Z
dc.date.available.spa.fl_str_mv 2019-06-27T23:53:59Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.uri.none.fl_str_mv https://repositorio.unal.edu.co/handle/unal/35070
dc.identifier.eprints.spa.fl_str_mv http://bdigital.unal.edu.co/25150/
url https://repositorio.unal.edu.co/handle/unal/35070
http://bdigital.unal.edu.co/25150/
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv http://revistas.unal.edu.co/index.php/dyna/article/view/22420
dc.relation.ispartof.spa.fl_str_mv Universidad Nacional de Colombia Revistas electrónicas UN Dyna
Dyna
dc.relation.ispartofseries.none.fl_str_mv Dyna; Vol. 79, núm. 176 (2012); 4-9 DYNA; Vol. 79, núm. 176 (2012); 4-9 2346-2183 0012-7353
dc.relation.references.spa.fl_str_mv Franco, Ediguer Enrique and Adamowski, Julio Cezar and Buiochi, Flávio (2012) Ultrasonic sensor for the presence of oily contaminants in water. Dyna; Vol. 79, núm. 176 (2012); 4-9 DYNA; Vol. 79, núm. 176 (2012); 4-9 2346-2183 0012-7353 .
dc.rights.spa.fl_str_mv Derechos reservados - Universidad Nacional de Colombia
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.license.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional
dc.rights.uri.spa.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv Atribución-NoComercial 4.0 Internacional
Derechos reservados - Universidad Nacional de Colombia
http://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Nacional de Colombia Sede Medellín
institution Universidad Nacional de Colombia
bitstream.url.fl_str_mv https://repositorio.unal.edu.co/bitstream/unal/35070/1/22420-191444-1-PB.html
https://repositorio.unal.edu.co/bitstream/unal/35070/2/22420-151091-1-PB.pdf
https://repositorio.unal.edu.co/bitstream/unal/35070/3/22420-151091-1-PB.pdf.jpg
bitstream.checksum.fl_str_mv f3ef73d540e88514ebb2f2ec008027f0
ed513de3b5813f93ec19f38c04f30eb5
9f3cfc7c6846cfb5bfc223ec93dcc577
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad Nacional de Colombia
repository.mail.fl_str_mv repositorio_nal@unal.edu.co
_version_ 1814090155462492160