Variation in risk category in methods of calculation of the modified fire load density
The management of fire safety in buildings is conducted in accordance with the type of use-risk category (Building occupancy code). For Building type XI "libraries and archives" and XII "industrial, workshops and warehouses", the determination of the risk category involves the ca...
- Autores:
-
Cadete-Pires, Cristina Maria Paulo
De Carvalho-Veiga, Rui António
Simões-Miguel, Maria Isabel
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2016
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/60568
- Acceso en línea:
- https://repositorio.unal.edu.co/handle/unal/60568
http://bdigital.unal.edu.co/58900/
- Palabra clave:
- 62 Ingeniería y operaciones afines / Engineering
Fire Safety in Buildings
fire load
deterministic
probabilistic.
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional
id |
UNACIONAL2_84e9a6ce4407c006be89e38d61267cca |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/60568 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
spelling |
Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Cadete-Pires, Cristina Maria Paulo9b28e2ab-7e14-4f29-bb47-28dadf8cf7bc300De Carvalho-Veiga, Rui António26d75e2f-64df-4035-9eaf-1f0f4f6a4a19300Simões-Miguel, Maria Isabel5b2c4017-5785-4c92-8c53-a8b090c7d6ff3002019-07-02T18:37:06Z2019-07-02T18:37:06Z2016-03-01ISSN: 2346-2183https://repositorio.unal.edu.co/handle/unal/60568http://bdigital.unal.edu.co/58900/The management of fire safety in buildings is conducted in accordance with the type of use-risk category (Building occupancy code). For Building type XI "libraries and archives" and XII "industrial, workshops and warehouses", the determination of the risk category involves the calculation of the modified fire load density, which can be done by two methods used interchangeably by the technician: deterministic and probabilistic. This study aims to investigate variation results obtained with the calculation of the modified fire load density using two methods and the classification of the Building occupancy code. The performed calculations referred to real buildings of type XII, with defined and distinct materials and activities. The different results determine a variation in the risk category, which consequently, will define the technical criteria to be applied to the Building occupancy code in the implementation for Building Fire Safety measures.application/pdfspaUniversidad Nacional de Colombia (Sede Medellín). Facultad de Minas.https://revistas.unal.edu.co/index.php/dyna/article/view/56602Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaCadete-Pires, Cristina Maria Paulo and De Carvalho-Veiga, Rui António and Simões-Miguel, Maria Isabel (2016) Variation in risk category in methods of calculation of the modified fire load density. DYNA, 83 (196). pp. 9-13. ISSN 2346-218362 Ingeniería y operaciones afines / EngineeringFire Safety in Buildingsfire loaddeterministicprobabilistic.Variation in risk category in methods of calculation of the modified fire load densityArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL56602-289917-1-PB.pdfapplication/pdf475783https://repositorio.unal.edu.co/bitstream/unal/60568/1/56602-289917-1-PB.pdf3f49f125cab57006ef0c18ccebf5e831MD51THUMBNAIL56602-289917-1-PB.pdf.jpg56602-289917-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg9268https://repositorio.unal.edu.co/bitstream/unal/60568/2/56602-289917-1-PB.pdf.jpg300d51d456e6b9c4c3d18993844a7db4MD52unal/60568oai:repositorio.unal.edu.co:unal/605682024-04-14 23:11:05.591Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co |
dc.title.spa.fl_str_mv |
Variation in risk category in methods of calculation of the modified fire load density |
title |
Variation in risk category in methods of calculation of the modified fire load density |
spellingShingle |
Variation in risk category in methods of calculation of the modified fire load density 62 Ingeniería y operaciones afines / Engineering Fire Safety in Buildings fire load deterministic probabilistic. |
title_short |
Variation in risk category in methods of calculation of the modified fire load density |
title_full |
Variation in risk category in methods of calculation of the modified fire load density |
title_fullStr |
Variation in risk category in methods of calculation of the modified fire load density |
title_full_unstemmed |
Variation in risk category in methods of calculation of the modified fire load density |
title_sort |
Variation in risk category in methods of calculation of the modified fire load density |
dc.creator.fl_str_mv |
Cadete-Pires, Cristina Maria Paulo De Carvalho-Veiga, Rui António Simões-Miguel, Maria Isabel |
dc.contributor.author.spa.fl_str_mv |
Cadete-Pires, Cristina Maria Paulo De Carvalho-Veiga, Rui António Simões-Miguel, Maria Isabel |
dc.subject.ddc.spa.fl_str_mv |
62 Ingeniería y operaciones afines / Engineering |
topic |
62 Ingeniería y operaciones afines / Engineering Fire Safety in Buildings fire load deterministic probabilistic. |
dc.subject.proposal.spa.fl_str_mv |
Fire Safety in Buildings fire load deterministic probabilistic. |
description |
The management of fire safety in buildings is conducted in accordance with the type of use-risk category (Building occupancy code). For Building type XI "libraries and archives" and XII "industrial, workshops and warehouses", the determination of the risk category involves the calculation of the modified fire load density, which can be done by two methods used interchangeably by the technician: deterministic and probabilistic. This study aims to investigate variation results obtained with the calculation of the modified fire load density using two methods and the classification of the Building occupancy code. The performed calculations referred to real buildings of type XII, with defined and distinct materials and activities. The different results determine a variation in the risk category, which consequently, will define the technical criteria to be applied to the Building occupancy code in the implementation for Building Fire Safety measures. |
publishDate |
2016 |
dc.date.issued.spa.fl_str_mv |
2016-03-01 |
dc.date.accessioned.spa.fl_str_mv |
2019-07-02T18:37:06Z |
dc.date.available.spa.fl_str_mv |
2019-07-02T18:37:06Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.coarversion.spa.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.issn.spa.fl_str_mv |
ISSN: 2346-2183 |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/60568 |
dc.identifier.eprints.spa.fl_str_mv |
http://bdigital.unal.edu.co/58900/ |
identifier_str_mv |
ISSN: 2346-2183 |
url |
https://repositorio.unal.edu.co/handle/unal/60568 http://bdigital.unal.edu.co/58900/ |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.spa.fl_str_mv |
https://revistas.unal.edu.co/index.php/dyna/article/view/56602 |
dc.relation.ispartof.spa.fl_str_mv |
Universidad Nacional de Colombia Revistas electrónicas UN Dyna Dyna |
dc.relation.references.spa.fl_str_mv |
Cadete-Pires, Cristina Maria Paulo and De Carvalho-Veiga, Rui António and Simões-Miguel, Maria Isabel (2016) Variation in risk category in methods of calculation of the modified fire load density. DYNA, 83 (196). pp. 9-13. ISSN 2346-2183 |
dc.rights.spa.fl_str_mv |
Derechos reservados - Universidad Nacional de Colombia |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial 4.0 Internacional Derechos reservados - Universidad Nacional de Colombia http://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Universidad Nacional de Colombia (Sede Medellín). Facultad de Minas. |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/60568/1/56602-289917-1-PB.pdf https://repositorio.unal.edu.co/bitstream/unal/60568/2/56602-289917-1-PB.pdf.jpg |
bitstream.checksum.fl_str_mv |
3f49f125cab57006ef0c18ccebf5e831 300d51d456e6b9c4c3d18993844a7db4 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814089271925014528 |