Caracterización y gestión segura de elementos activados en ciclotrones médicos en Colombia
ilustraciones, diagramas
- Autores:
-
González Sánchez, Mercy Natalia
- Tipo de recurso:
- Fecha de publicación:
- 2023
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/84266
- Palabra clave:
- 530 - Física
DISPOSICION DE RESIDUOS RADIACTIVOS
Radioactive waste disposal
Ciclotrón
Radionúclidos
Desechos radiactivos
Dosis de radiación
Espectrometría gamma
Cyclotron
Radionuclides
Radioactive waste
Radiation dose
Gamma spectrometry
- Rights
- openAccess
- License
- Atribución-NoComercial-SinDerivadas 4.0 Internacional
id |
UNACIONAL2_7b9736420cffa3bcea43c37416387a3c |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/84266 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
dc.title.spa.fl_str_mv |
Caracterización y gestión segura de elementos activados en ciclotrones médicos en Colombia |
dc.title.translated.eng.fl_str_mv |
Characterization and safe management of activated elements in medical cyclotrons in Colombia |
title |
Caracterización y gestión segura de elementos activados en ciclotrones médicos en Colombia |
spellingShingle |
Caracterización y gestión segura de elementos activados en ciclotrones médicos en Colombia 530 - Física DISPOSICION DE RESIDUOS RADIACTIVOS Radioactive waste disposal Ciclotrón Radionúclidos Desechos radiactivos Dosis de radiación Espectrometría gamma Cyclotron Radionuclides Radioactive waste Radiation dose Gamma spectrometry |
title_short |
Caracterización y gestión segura de elementos activados en ciclotrones médicos en Colombia |
title_full |
Caracterización y gestión segura de elementos activados en ciclotrones médicos en Colombia |
title_fullStr |
Caracterización y gestión segura de elementos activados en ciclotrones médicos en Colombia |
title_full_unstemmed |
Caracterización y gestión segura de elementos activados en ciclotrones médicos en Colombia |
title_sort |
Caracterización y gestión segura de elementos activados en ciclotrones médicos en Colombia |
dc.creator.fl_str_mv |
González Sánchez, Mercy Natalia |
dc.contributor.advisor.none.fl_str_mv |
Olaya Dávila, Hernán Olaya Agulles Pedrós, Luis |
dc.contributor.author.none.fl_str_mv |
González Sánchez, Mercy Natalia |
dc.subject.ddc.spa.fl_str_mv |
530 - Física |
topic |
530 - Física DISPOSICION DE RESIDUOS RADIACTIVOS Radioactive waste disposal Ciclotrón Radionúclidos Desechos radiactivos Dosis de radiación Espectrometría gamma Cyclotron Radionuclides Radioactive waste Radiation dose Gamma spectrometry |
dc.subject.lemb.spa.fl_str_mv |
DISPOSICION DE RESIDUOS RADIACTIVOS |
dc.subject.lemb.eng.fl_str_mv |
Radioactive waste disposal |
dc.subject.proposal.spa.fl_str_mv |
Ciclotrón Radionúclidos Desechos radiactivos Dosis de radiación Espectrometría gamma |
dc.subject.proposal.eng.fl_str_mv |
Cyclotron Radionuclides Radioactive waste Radiation dose Gamma spectrometry |
description |
ilustraciones, diagramas |
publishDate |
2023 |
dc.date.accessioned.none.fl_str_mv |
2023-07-25T19:37:59Z |
dc.date.available.none.fl_str_mv |
2023-07-25T19:37:59Z |
dc.date.issued.none.fl_str_mv |
2023 |
dc.type.spa.fl_str_mv |
Trabajo de grado - Maestría |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/masterThesis |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/acceptedVersion |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/TM |
status_str |
acceptedVersion |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/84266 |
dc.identifier.instname.spa.fl_str_mv |
Universidad Nacional de Colombia |
dc.identifier.reponame.spa.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
dc.identifier.repourl.spa.fl_str_mv |
https://repositorio.unal.edu.co/ |
url |
https://repositorio.unal.edu.co/handle/unal/84266 https://repositorio.unal.edu.co/ |
identifier_str_mv |
Universidad Nacional de Colombia Repositorio Institucional Universidad Nacional de Colombia |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.references.spa.fl_str_mv |
[1] Principio y funcionamiento del ciclotrón. https://www.youtube.com/watch?v=m2jp0klZHEE&t=25s, 2017. [2] Wayne D Newhauser and Rui Zhang. The physics of proton therapy. Physics in Medicine & Biology, 60(8):R155, 2015. [3] J Carbajo Chaves, M Jurado Vargas, and R Sánchez Sánchez. Measurement of activation products generated in the [18f] fdg production by a 9.6 mev cyclotron. Radiation Physics and Chemistry, 126:32–36, 2016. [4] IAEA ENSDF. Live chart of nuclides nuclear structure and decay data. https://www-nds.iaea.org/relnsd/vcharthtml/VChartHTML.html, 2019. [6] Instalación centralizada para la gestión de desechos radiactivos. https://www2.sgc.gov.co/ProgramasDeInvestigacion/AsuntosNucleares/Paginas/gestion-de-desechos-radiactivos.aspx. [7] Viales. https://www.pharmaceutical-business-review.com/wp-content/uploads/2014/05/schott-brochure-schott-vials-english-20092017.pdf. [8] STRACOTEK. Sc40 / eclipse hp. https://www.stracotek.com/ files/ugd/1cf900813ed8eb0407425e88e3e1a76908a2f2.pdf. [9] STRACOTEK. Liquid targets for pettrace cyclotrons. https://www.stracotek.com/files/ugd/1cf900 07fb8a9182794550a35931f7bf60603f.pdf. [10] International Atomic Energy Association IAEA. Cyclotron produced radionuclides: principles and practice. Technical report, No. 465. Technical Reports Series, 2008. [11] Resolución 180005 2010 ”por la cual se adopta el reglamento para la gestión de los desechos radiactivos en Colombia, 2010. [12] Informes de seguridad - normas básicas internacionales de seguridad para la protección contra la radiación ionizante y para la seguridad de las fuentes de radiación., 1997. [13] Resolución 181434 de 2002 ”por la cual se adopta el reglamento de protección y seguridad radiológica, 2002. [14] David S Smith and Michael G Stabin. Exposure rate constants and lead shielding values for over 1,100 radionuclides. Health physics, 102(3):271–291, 2012. [15] BALTIC SCIENTIFIC INSTRUMENTS. Semiconductors detectors nuclear electronics for radiation measurements. https://bsi.lv/media/uploads/bsi catalogue.pdf. [16] Thermo scientific radeye b20 / b20-er. https://www.thermofisher.com/document-connect/document-connect.html?url=https://assets.thermofisher.com/TFS-Assets%2FCAD%2FSpecification-Sheets%2FRadEye-B20-e-V1-0-A4.pdf. [17] Graetz x 50. https://www.tecnitestndt.net/wp-content/uploads/2020/01/Detectores-de-radiaci%C3%B3n.pdf. [18] IAEA. Database of cyclotrons for radionuclide production. https://nucleus.iaea.org/sites/accelerators/Pages/Cyclotron.aspx, 2006. [19] Servicio Geológico Colombiano. Instalaciones autorizadas para el empleo de material radiactivo. https://www2.sgc.gov.co/ProgramasDeInvestigacion/AsuntosNucleares/Documents/instalaciones-autorizadas/instalaciones-autorizadas-24-11-2022.pdf, 2022. [20] Yamil Chain and Luis Illanes. Radiofármacos en medicina nuclear fundamentos y aplicación clínica. Facultad de Ciencias Exactas, Edulp (Editorial de la Universidad de la Plata, Libros de Cátedra, 188pp, 2015. [21] Instituto Colombiano de Normas Técnicas y Certificación ICONTEC. Transporte de mercancías peligrosas clase 7. materiales radiactivos. transporte terrestre por carretera. https://web.mintransporte.gov.co/consultas/mercapeli/Reglamento/Anexos/NTC3970.pdf. [22] Magdalena D lugosz-Lisiecka, Teresa Jakubowska, and Magdalena Zbrojewska. Forma tion of 107cd radionuclide impurities during 18f production. Applied Radiation and Isotopes, 147:48–53, 2019. [23] P Guarino, S Rizzo, E Tomarchio, and D Greco. Gamma-ray spectrometric characterization of waste activated target components in a pet cyclotron. Cyclotrons and Their Applications, 1:295, 2007. [24] R Calandrino, A Del Vecchio, R Parisi, S Todde, P De Felice, A Savi, A Pepe, and A Mrskova. Measurements and evaluation of the risks due to external radiation exposures and to intake of activated elements for operational staff engaged in the maintenance of medical cyclotrons. Radiation protection dosimetry, 139(4):477–482, 2010. [25] M Jurado Vargas, JC Carbajo Chávez, R Sánchez S´anchez, and C Sosa. Gamma-ray measurements of the activated target components in a cyclotron used for positron emission tomography. Radiation Physics and Chemistry, 177:109–153, 2020. [26] Jesús Carlos Carbajo Chávez. Aplicación de la espectrometría de radiación gamma de alta resolución en la producción de los radiof´armacos [18f ] fdg y quadramet [153sm] edtmp. PhD thesis, Universidad de Extremadura, 2020. [27] Diana Isabel Páez Gutiérrez, Amelia De los Reyes, and Augusto Llamas Olier. La tomografía por emisión de positrones: nuevo paradigma para la evaluación y el manejo del cáncer. 2006. [28] Karel Strijckmans. The isochronous cyclotron: principles and recent developments. Computerized medical imaging and graphics, 25(2):69–78, 2001. [29] AC Medrano S, E Barrera G, and H Valdovinos U. Characterization of the proton beam profile of an iba 18/9 cyclotron with ebt3 radiochromic films. 2019. [30] Charles Kittel and Walter D Knight. Mecánica, volume 1. Reverté, 1982. [31] Seo Hyun Park and Jin Oh Kang. Basics of particle therapy i: physics. Radiation oncology journal, 29(3):135, 2011. [32] Gumercindo Raul Vila Porras. Efecto del etanol sobre la estabilidad del radiofármaco 2-[18f] fluoro-2-desoxi-d-glucosa. 2020. [33] Teresa Bas Andreu. ESTUDIO DE LA PRODUCCION CON CICLOTRÓN DE RADIONUCLEIDOS PARA TOMOGRAFIA POR EMISION DE POSITRONES (PET) . PhD thesis, Universitat Politécnica de Valencia, 2020. [34] M Alanis et al. General aspects of the cyclotrons and radiochemical separation of: 11 c, 15 o, 18 f and 14 n. Technical report, Instituto Nacional de Investigaciones Nucleares, 1997. [35] Adolfo Obaya Valdivia, Jesús López López, Yolanda Marina Vargas-Rodríguez, and Oyuki Camacho González. Producción de radiofármacos para tomografía por emisión de positrones (pet) y su aplicación en el diagnostico de diversas enfermedades. Educación química, 27(4):292–299, 2016. [36] David Dowsett, Patrick A Kenny, and R Eugene Johnston. The physics of diagnostic imaging. CRC Press, 2006. [37] MM B´e, V Chist´e, C Dulieu, X Mougeot, E Browne, V Chechev, N Kuzmenko, F Kondev, A Luca, M Galan, et al. Table of radionuclides (vol. 5–a 22 to 244), monographie bipm-5, vol. 5. Bureau International des Poids et Mesures, Sevres, France. See also Browne, E., Bé, M.-M., Helmer, RG, page 71, 2004. [38] Elio Tomarchio. Measurement of radionuclide activities induced in target components of an iba cyclone 18/9 by gamma-ray spectrometry with hpge and labr3: Ce detectors. Health Physics, 107(2):S143–S152, 2014. [39] FRANCISCO JAVIER CABRERA ORELLANA. ESTIMACION DE LA TEMPERA TURA DE UN DETECTOR DE GERMANIO HIPERPURO. PhD thesis, UNIVER SIDAD DE SANTIAGO DE CHILE, 2014. [40] Gordon Gilmore. Practical gamma-ray spectroscopy. John Wiley & Sons, 2008. [41] Fernando Cristancho. Instrumentación nuclear-practicas experimentales, 2021. [42] JC Aguiar and JA Fernández. Determinación de actividad por espectrometría gamma de radio-nucleidos presentes en tambores de residuos gen-erados en centrales nucleares. Primer Congreso Americano del IRPA. Acapulco, pages 4–8, 2006. [43] Colección de normas de seguridad del oiea. aplicación de los conceptos de exclusión, exención y dispensa. guía de seguridad rs-g-1.7, 2007. [44] Las recomendaciones 2007 de la comisión internacional de protección radiológica, 2007. 45] P Hahn. An overview of the iaea activities on occupational radiation protection. In Occupational Radiation Protection: Enhancing the Protection of Workers—Gaps, Challenges and Developments. Proceedings of an International Conference, [46] Zuluaga P Mosos J Hurtado J Ospina A, Prada T. Caracterización por espectrometría gamma de ventanas y rejillas metálicas activadas en la operación de un ciclotrón siemens eclipse para producción de 18 f. https://minas.medellin.unal.edu.co/images/XICIM/PROGRAMA XI CIM 2022 VERSION PRELIMINAR.pdf, 2022. [47] Resolución 181682 de 2005 ”por la cual se adopta el reglamento para el transporte seguro de materiales radiactivos, 2005. [48] Colección Seguridad N IAEA. 115: Normas básicas internacionales de seguridad para la protección contra las radiación ionizante y para la seguridad de las fuentes de radiación. IAEA, Viena, Austria, 1997. [49] Ministerio de Minas y Energía. Resolución ”por la cual se adopta el reglamento para el transporte seguro de materiales radiactivos y se reglamenta la seguridad física en el transporte. https://www.minenergia.gov.co/documents/7331/091220 Reglamento para el Transporte Seguro de Materiales Radiactivos.pdf. [50] Alejandro E Condori Alvarado. Caracterización de eficiencia de detección de sistemas de espectrometría gamma con detector CZT compacto para uso en medicina nuclear y PET, por medio de modelado montecarlo. PhD thesis, Universidad Nacional de Cuyo, 2019. [51] Baltic Scientific Instruments. Spectraline software. linear spectra processing. user’s manual., 2015. |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial-SinDerivadas 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial-SinDerivadas 4.0 Internacional http://creativecommons.org/licenses/by-nc-nd/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.extent.spa.fl_str_mv |
xii, 85 páginas |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Universidad Nacional de Colombia |
dc.publisher.program.spa.fl_str_mv |
Bogotá - Ciencias - Maestría en Física Médica |
dc.publisher.faculty.spa.fl_str_mv |
Facultad de Ciencias |
dc.publisher.place.spa.fl_str_mv |
Bogotá, Colombia |
dc.publisher.branch.spa.fl_str_mv |
Universidad Nacional de Colombia - Sede Bogotá |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/84266/2/1049644307.2023.pdf https://repositorio.unal.edu.co/bitstream/unal/84266/1/license.txt https://repositorio.unal.edu.co/bitstream/unal/84266/3/1049644307.2023.pdf.jpg |
bitstream.checksum.fl_str_mv |
85d4d907d0599a815de7489972ce8577 eb34b1cf90b7e1103fc9dfd26be24b4a 5736c2b9dddb174a1ce96b75080318ba |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814089540409753600 |
spelling |
Atribución-NoComercial-SinDerivadas 4.0 Internacionalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Olaya Dávila, Hernán Olayacaee3cde9ca2d9f27303abc47ddc1088Agulles Pedrós, Luis55865ee69ecbd0586a81c0456cb2d0e4González Sánchez, Mercy Natalia10b748e4a9d8ae1d9f6843e832e21ac12023-07-25T19:37:59Z2023-07-25T19:37:59Z2023https://repositorio.unal.edu.co/handle/unal/84266Universidad Nacional de ColombiaRepositorio Institucional Universidad Nacional de Colombiahttps://repositorio.unal.edu.co/ilustraciones, diagramasMediante espectrometría gamma de alta resolución, se realizó la caracterización de aguas recuperadas y algunas piezas activadas como lámina de havar y junta helicoflex, provenientes de la configuración del blanco objetivo para dos ciclotrones médicos ubicados en los departamentos de Cundinamarca y Antioquía. Según resultados provenientes de publicaciones internacionales, no solo las piezas de la configuración del blanco se activan por la interacción de los protones con los distintos materiales y por ello, con el fin de identificar los radionúclidos presentes en las piezas y cuantificar su actividad, nos dimos a la tarea de también caracterizar una columna de QMA y una muestra del residuo del filtro de la bomba de vacío para uno de los ciclotrones. Los resultados de la identificación de radionúclidos muestran que las aguas recuperadas y las láminas de havar se activan con Co-56 y Co-57 siendo las láminas de havar las que contienen mayor actividad. Las incertidumbres asociadas a la cuantificación de actividad para cada pieza analizada, se encuentran por debajo del 12%. El residuo del filtro de la bomba de vacío del ciclotrón Siemens Hp Eclipse, se activa con Zn-65, este material particulado emisor de radiación ionizante debe ser manipulado con guantes, gafas y mascarilla adecuados. Adicionalmente, se calcularon las tasas de dosis a las que está expuesto el personal ocupacional cuando se encuentran en actividades de extracción de las piezas del blanco del ciclotrón y cuando realizan traslados a la zona de almacenamiento temporal de los desechos radiactivos dentro de las instalaciones del ciclotrón médico. Con base en la normatividad nacional e internacional y los resultados obtenidos, se realiza un protocolo como complemento para la gestión de desechos radiactivos en ciclotrones médicos, con el objetivo de guiar a las instalaciones sobre las etapas de gestión, en especial, los tiempos de almacenamiento temporal para las piezas del blanco del ciclotrón activadas y además concientizar sobre la responsabilidad de dar el manejo adecuado a los residuos generados evitando riesgos de irradiación innecesarios al medio ambiente y al personal del público. (Texto tomado de la fuente)Using high-resolution gamma spectrometry, the characterization of recovered water and some activated pieces such as havar sheets and helicoflex joint, coming from the configuration of the target target for two medical cyclotrons located in the departments of Cundinamarca and Antioquía, was carried out. According to results from international publications, not only the pieces of the target configuration are activated by the interaction of the protons with the different materials and therefore, in order to identify the radionuclides present in the pieces and quantify the activity, we gave ourselves to the task of also characterizing a QMA column and a sample of the vacuum pump filter residue for one of the cyclotrons. The results of the identification of radionuclides show that the recovered waters and the havar sheets are activated with Co-56 and Co-57, with the havar sheets containing the highest activity. The uncertainties obtained from the quantification of activity for each piece analyzed are below 12%. The residue from the filter of the vacuum pump of the Siemens Hp Eclipse cyclotron is activated with Zn-65, a particulate material that emits ionizing radiation. It must be handled with suitable gloves, glasses and a mask. Additionally, the dose rates to which occupational personnel are exposed when they are in activities of extraction of the cyclotron target pieces and when they make transfers to the temporary storage area of radioactive waste within the cyclotron facilities were calculated. Based on national and international regulations and the results obtained, a protocol is carried out as a complement for the management of radioactive waste in medical cyclotrons, with the aim of guiding the facilities on the management stages, especially storage times. temporary for the activated cyclotron target parts and also raise awareness about the responsibility of giving proper management to the waste generated, avoiding unnecessary irradiation risks to the environment and public personnel.MaestríaMagíster en Física Médicaxii, 85 páginasapplication/pdfspaUniversidad Nacional de ColombiaBogotá - Ciencias - Maestría en Física MédicaFacultad de CienciasBogotá, ColombiaUniversidad Nacional de Colombia - Sede Bogotá530 - FísicaDISPOSICION DE RESIDUOS RADIACTIVOSRadioactive waste disposalCiclotrónRadionúclidosDesechos radiactivosDosis de radiaciónEspectrometría gammaCyclotronRadionuclidesRadioactive wasteRadiation doseGamma spectrometryCaracterización y gestión segura de elementos activados en ciclotrones médicos en ColombiaCharacterization and safe management of activated elements in medical cyclotrons in ColombiaTrabajo de grado - Maestríainfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/acceptedVersionTexthttp://purl.org/redcol/resource_type/TM[1] Principio y funcionamiento del ciclotrón. https://www.youtube.com/watch?v=m2jp0klZHEE&t=25s, 2017.[2] Wayne D Newhauser and Rui Zhang. The physics of proton therapy. Physics in Medicine & Biology, 60(8):R155, 2015.[3] J Carbajo Chaves, M Jurado Vargas, and R Sánchez Sánchez. Measurement of activation products generated in the [18f] fdg production by a 9.6 mev cyclotron. Radiation Physics and Chemistry, 126:32–36, 2016.[4] IAEA ENSDF. Live chart of nuclides nuclear structure and decay data. https://www-nds.iaea.org/relnsd/vcharthtml/VChartHTML.html, 2019.[6] Instalación centralizada para la gestión de desechos radiactivos. https://www2.sgc.gov.co/ProgramasDeInvestigacion/AsuntosNucleares/Paginas/gestion-de-desechos-radiactivos.aspx.[7] Viales. https://www.pharmaceutical-business-review.com/wp-content/uploads/2014/05/schott-brochure-schott-vials-english-20092017.pdf.[8] STRACOTEK. Sc40 / eclipse hp. https://www.stracotek.com/ files/ugd/1cf900813ed8eb0407425e88e3e1a76908a2f2.pdf.[9] STRACOTEK. Liquid targets for pettrace cyclotrons. https://www.stracotek.com/files/ugd/1cf900 07fb8a9182794550a35931f7bf60603f.pdf.[10] International Atomic Energy Association IAEA. Cyclotron produced radionuclides: principles and practice. Technical report, No. 465. Technical Reports Series, 2008.[11] Resolución 180005 2010 ”por la cual se adopta el reglamento para la gestión de los desechos radiactivos en Colombia, 2010.[12] Informes de seguridad - normas básicas internacionales de seguridad para la protección contra la radiación ionizante y para la seguridad de las fuentes de radiación., 1997.[13] Resolución 181434 de 2002 ”por la cual se adopta el reglamento de protección y seguridad radiológica, 2002.[14] David S Smith and Michael G Stabin. Exposure rate constants and lead shielding values for over 1,100 radionuclides. Health physics, 102(3):271–291, 2012.[15] BALTIC SCIENTIFIC INSTRUMENTS. Semiconductors detectors nuclear electronics for radiation measurements. https://bsi.lv/media/uploads/bsi catalogue.pdf.[16] Thermo scientific radeye b20 / b20-er. https://www.thermofisher.com/document-connect/document-connect.html?url=https://assets.thermofisher.com/TFS-Assets%2FCAD%2FSpecification-Sheets%2FRadEye-B20-e-V1-0-A4.pdf.[17] Graetz x 50. https://www.tecnitestndt.net/wp-content/uploads/2020/01/Detectores-de-radiaci%C3%B3n.pdf.[18] IAEA. Database of cyclotrons for radionuclide production. https://nucleus.iaea.org/sites/accelerators/Pages/Cyclotron.aspx, 2006.[19] Servicio Geológico Colombiano. Instalaciones autorizadas para el empleo de material radiactivo. https://www2.sgc.gov.co/ProgramasDeInvestigacion/AsuntosNucleares/Documents/instalaciones-autorizadas/instalaciones-autorizadas-24-11-2022.pdf, 2022.[20] Yamil Chain and Luis Illanes. Radiofármacos en medicina nuclear fundamentos y aplicación clínica. Facultad de Ciencias Exactas, Edulp (Editorial de la Universidad de la Plata, Libros de Cátedra, 188pp, 2015.[21] Instituto Colombiano de Normas Técnicas y Certificación ICONTEC. Transporte de mercancías peligrosas clase 7. materiales radiactivos. transporte terrestre por carretera. https://web.mintransporte.gov.co/consultas/mercapeli/Reglamento/Anexos/NTC3970.pdf.[22] Magdalena D lugosz-Lisiecka, Teresa Jakubowska, and Magdalena Zbrojewska. Forma tion of 107cd radionuclide impurities during 18f production. Applied Radiation and Isotopes, 147:48–53, 2019.[23] P Guarino, S Rizzo, E Tomarchio, and D Greco. Gamma-ray spectrometric characterization of waste activated target components in a pet cyclotron. Cyclotrons and Their Applications, 1:295, 2007.[24] R Calandrino, A Del Vecchio, R Parisi, S Todde, P De Felice, A Savi, A Pepe, and A Mrskova. Measurements and evaluation of the risks due to external radiation exposures and to intake of activated elements for operational staff engaged in the maintenance of medical cyclotrons. Radiation protection dosimetry, 139(4):477–482, 2010.[25] M Jurado Vargas, JC Carbajo Chávez, R Sánchez S´anchez, and C Sosa. Gamma-ray measurements of the activated target components in a cyclotron used for positron emission tomography. Radiation Physics and Chemistry, 177:109–153, 2020.[26] Jesús Carlos Carbajo Chávez. Aplicación de la espectrometría de radiación gamma de alta resolución en la producción de los radiof´armacos [18f ] fdg y quadramet [153sm] edtmp. PhD thesis, Universidad de Extremadura, 2020.[27] Diana Isabel Páez Gutiérrez, Amelia De los Reyes, and Augusto Llamas Olier. La tomografía por emisión de positrones: nuevo paradigma para la evaluación y el manejo del cáncer. 2006.[28] Karel Strijckmans. The isochronous cyclotron: principles and recent developments. Computerized medical imaging and graphics, 25(2):69–78, 2001.[29] AC Medrano S, E Barrera G, and H Valdovinos U. Characterization of the proton beam profile of an iba 18/9 cyclotron with ebt3 radiochromic films. 2019.[30] Charles Kittel and Walter D Knight. Mecánica, volume 1. Reverté, 1982.[31] Seo Hyun Park and Jin Oh Kang. Basics of particle therapy i: physics. Radiation oncology journal, 29(3):135, 2011.[32] Gumercindo Raul Vila Porras. Efecto del etanol sobre la estabilidad del radiofármaco 2-[18f] fluoro-2-desoxi-d-glucosa. 2020.[33] Teresa Bas Andreu. ESTUDIO DE LA PRODUCCION CON CICLOTRÓN DE RADIONUCLEIDOS PARA TOMOGRAFIA POR EMISION DE POSITRONES (PET) . PhD thesis, Universitat Politécnica de Valencia, 2020.[34] M Alanis et al. General aspects of the cyclotrons and radiochemical separation of: 11 c, 15 o, 18 f and 14 n. Technical report, Instituto Nacional de Investigaciones Nucleares, 1997.[35] Adolfo Obaya Valdivia, Jesús López López, Yolanda Marina Vargas-Rodríguez, and Oyuki Camacho González. Producción de radiofármacos para tomografía por emisión de positrones (pet) y su aplicación en el diagnostico de diversas enfermedades. Educación química, 27(4):292–299, 2016.[36] David Dowsett, Patrick A Kenny, and R Eugene Johnston. The physics of diagnostic imaging. CRC Press, 2006.[37] MM B´e, V Chist´e, C Dulieu, X Mougeot, E Browne, V Chechev, N Kuzmenko, F Kondev, A Luca, M Galan, et al. Table of radionuclides (vol. 5–a 22 to 244), monographie bipm-5, vol. 5. Bureau International des Poids et Mesures, Sevres, France. See also Browne, E., Bé, M.-M., Helmer, RG, page 71, 2004.[38] Elio Tomarchio. Measurement of radionuclide activities induced in target components of an iba cyclone 18/9 by gamma-ray spectrometry with hpge and labr3: Ce detectors. Health Physics, 107(2):S143–S152, 2014.[39] FRANCISCO JAVIER CABRERA ORELLANA. ESTIMACION DE LA TEMPERA TURA DE UN DETECTOR DE GERMANIO HIPERPURO. PhD thesis, UNIVER SIDAD DE SANTIAGO DE CHILE, 2014.[40] Gordon Gilmore. Practical gamma-ray spectroscopy. John Wiley & Sons, 2008.[41] Fernando Cristancho. Instrumentación nuclear-practicas experimentales, 2021.[42] JC Aguiar and JA Fernández. Determinación de actividad por espectrometría gamma de radio-nucleidos presentes en tambores de residuos gen-erados en centrales nucleares. Primer Congreso Americano del IRPA. Acapulco, pages 4–8, 2006.[43] Colección de normas de seguridad del oiea. aplicación de los conceptos de exclusión, exención y dispensa. guía de seguridad rs-g-1.7, 2007.[44] Las recomendaciones 2007 de la comisión internacional de protección radiológica, 2007.45] P Hahn. An overview of the iaea activities on occupational radiation protection. In Occupational Radiation Protection: Enhancing the Protection of Workers—Gaps, Challenges and Developments. Proceedings of an International Conference,[46] Zuluaga P Mosos J Hurtado J Ospina A, Prada T. Caracterización por espectrometría gamma de ventanas y rejillas metálicas activadas en la operación de un ciclotrón siemens eclipse para producción de 18 f. https://minas.medellin.unal.edu.co/images/XICIM/PROGRAMA XI CIM 2022 VERSION PRELIMINAR.pdf, 2022.[47] Resolución 181682 de 2005 ”por la cual se adopta el reglamento para el transporte seguro de materiales radiactivos, 2005.[48] Colección Seguridad N IAEA. 115: Normas básicas internacionales de seguridad para la protección contra las radiación ionizante y para la seguridad de las fuentes de radiación. IAEA, Viena, Austria, 1997.[49] Ministerio de Minas y Energía. Resolución ”por la cual se adopta el reglamento para el transporte seguro de materiales radiactivos y se reglamenta la seguridad física en el transporte. https://www.minenergia.gov.co/documents/7331/091220 Reglamento para el Transporte Seguro de Materiales Radiactivos.pdf.[50] Alejandro E Condori Alvarado. Caracterización de eficiencia de detección de sistemas de espectrometría gamma con detector CZT compacto para uso en medicina nuclear y PET, por medio de modelado montecarlo. PhD thesis, Universidad Nacional de Cuyo, 2019.[51] Baltic Scientific Instruments. Spectraline software. linear spectra processing. user’s manual., 2015.EstudiantesInvestigadoresMaestrosORIGINAL1049644307.2023.pdf1049644307.2023.pdfTesis de Maestría en Física Médicaapplication/pdf21979621https://repositorio.unal.edu.co/bitstream/unal/84266/2/1049644307.2023.pdf85d4d907d0599a815de7489972ce8577MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-85879https://repositorio.unal.edu.co/bitstream/unal/84266/1/license.txteb34b1cf90b7e1103fc9dfd26be24b4aMD51THUMBNAIL1049644307.2023.pdf.jpg1049644307.2023.pdf.jpgGenerated Thumbnailimage/jpeg3978https://repositorio.unal.edu.co/bitstream/unal/84266/3/1049644307.2023.pdf.jpg5736c2b9dddb174a1ce96b75080318baMD53unal/84266oai:repositorio.unal.edu.co:unal/842662024-08-14 23:42:31.314Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.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 |