Evaluation of mass-rig systems for shaking table experiments

Shaking tables are experimental tools to assess the behavior of structures and nonstructural components under characteristic seismic vibrations. Because of the size and weight limitations of the tables, testing reduced-scale models or testing only the main structural components are normally necessar...

Full description

Autores:
Carrillo León, Julián
González Peñuela, Noel Giovanni
Llano Sanchez, Luis
Tipo de recurso:
Article of journal
Fecha de publicación:
2012
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/39731
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/39731
http://bdigital.unal.edu.co/29828/
Palabra clave:
shaking table test
dynamic system
mass
test equipment
Rights
openAccess
License
Atribución-NoComercial 4.0 Internacional
id UNACIONAL2_6f383f07f35ca5c83e0368b66f622884
oai_identifier_str oai:repositorio.unal.edu.co:unal/39731
network_acronym_str UNACIONAL2
network_name_str Universidad Nacional de Colombia
repository_id_str
spelling Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Carrillo León, Julián49f79b46-c0ce-4fd5-aae4-a5c753406011300González Peñuela, Noel Giovanni43e4c444-cc50-4370-944b-7d914cb2b29e300Llano Sanchez, Luis96537bb1-0577-40f9-ba12-1397cef8d77f3002019-06-28T04:20:57Z2019-06-28T04:20:57Z2012https://repositorio.unal.edu.co/handle/unal/39731http://bdigital.unal.edu.co/29828/Shaking tables are experimental tools to assess the behavior of structures and nonstructural components under characteristic seismic vibrations. Because of the size and weight limitations of the tables, testing reduced-scale models or testing only the main structural components are normally necessary. In these cases, to comply with modeling requirements, large amount of extra-mass should be added to the specimen. This paper reviews and discusses the mass-rig systems for shaking table testing. The advantages and drawbacks of each system are critically compared. To avoid the risk of lateral instability of models and to maintain the weight of test specimens within table payload, external devices for transmitting the inertial forces to the models have become a preferred choice when tests are performed using small- or medium-size shaking tables.application/pdfspaUniversidad Nacional de Colombia Sede Medellínhttp://revistas.unal.edu.co/index.php/dyna/article/view/28509Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaDyna; Vol. 79, núm. 176 (2012); 159-167 DYNA; Vol. 79, núm. 176 (2012); 159-167 2346-2183 0012-7353Carrillo León, Julián and González Peñuela, Noel Giovanni and Llano Sanchez, Luis (2012) Evaluation of mass-rig systems for shaking table experiments. Dyna; Vol. 79, núm. 176 (2012); 159-167 DYNA; Vol. 79, núm. 176 (2012); 159-167 2346-2183 0012-7353 .Evaluation of mass-rig systems for shaking table experimentsArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTshaking table testdynamic systemmasstest equipmentORIGINAL28509-191462-1-PB.htmltext/html43282https://repositorio.unal.edu.co/bitstream/unal/39731/1/28509-191462-1-PB.htmle40cb9c57d386d449470f9c7a04fe540MD5128509-102049-1-SP.pdfapplication/pdf26677https://repositorio.unal.edu.co/bitstream/unal/39731/2/28509-102049-1-SP.pdff6fec271d7bc3532231253caf96e1e5dMD5228509-151109-1-PB.pdfapplication/pdf633292https://repositorio.unal.edu.co/bitstream/unal/39731/3/28509-151109-1-PB.pdf84f44d83223666a1d8c3e62bbf69a2c0MD53THUMBNAIL28509-102049-1-SP.pdf.jpg28509-102049-1-SP.pdf.jpgGenerated Thumbnailimage/jpeg7851https://repositorio.unal.edu.co/bitstream/unal/39731/4/28509-102049-1-SP.pdf.jpgcf4ea8eac02d001a315586fa315a5f54MD5428509-151109-1-PB.pdf.jpg28509-151109-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg9376https://repositorio.unal.edu.co/bitstream/unal/39731/5/28509-151109-1-PB.pdf.jpgd1e07b40488e66aed3a0195c35394880MD55unal/39731oai:repositorio.unal.edu.co:unal/397312024-01-21 23:06:27.099Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co
dc.title.spa.fl_str_mv Evaluation of mass-rig systems for shaking table experiments
title Evaluation of mass-rig systems for shaking table experiments
spellingShingle Evaluation of mass-rig systems for shaking table experiments
shaking table test
dynamic system
mass
test equipment
title_short Evaluation of mass-rig systems for shaking table experiments
title_full Evaluation of mass-rig systems for shaking table experiments
title_fullStr Evaluation of mass-rig systems for shaking table experiments
title_full_unstemmed Evaluation of mass-rig systems for shaking table experiments
title_sort Evaluation of mass-rig systems for shaking table experiments
dc.creator.fl_str_mv Carrillo León, Julián
González Peñuela, Noel Giovanni
Llano Sanchez, Luis
dc.contributor.author.spa.fl_str_mv Carrillo León, Julián
González Peñuela, Noel Giovanni
Llano Sanchez, Luis
dc.subject.proposal.spa.fl_str_mv shaking table test
dynamic system
mass
test equipment
topic shaking table test
dynamic system
mass
test equipment
description Shaking tables are experimental tools to assess the behavior of structures and nonstructural components under characteristic seismic vibrations. Because of the size and weight limitations of the tables, testing reduced-scale models or testing only the main structural components are normally necessary. In these cases, to comply with modeling requirements, large amount of extra-mass should be added to the specimen. This paper reviews and discusses the mass-rig systems for shaking table testing. The advantages and drawbacks of each system are critically compared. To avoid the risk of lateral instability of models and to maintain the weight of test specimens within table payload, external devices for transmitting the inertial forces to the models have become a preferred choice when tests are performed using small- or medium-size shaking tables.
publishDate 2012
dc.date.issued.spa.fl_str_mv 2012
dc.date.accessioned.spa.fl_str_mv 2019-06-28T04:20:57Z
dc.date.available.spa.fl_str_mv 2019-06-28T04:20:57Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.uri.none.fl_str_mv https://repositorio.unal.edu.co/handle/unal/39731
dc.identifier.eprints.spa.fl_str_mv http://bdigital.unal.edu.co/29828/
url https://repositorio.unal.edu.co/handle/unal/39731
http://bdigital.unal.edu.co/29828/
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv http://revistas.unal.edu.co/index.php/dyna/article/view/28509
dc.relation.ispartof.spa.fl_str_mv Universidad Nacional de Colombia Revistas electrónicas UN Dyna
Dyna
dc.relation.ispartofseries.none.fl_str_mv Dyna; Vol. 79, núm. 176 (2012); 159-167 DYNA; Vol. 79, núm. 176 (2012); 159-167 2346-2183 0012-7353
dc.relation.references.spa.fl_str_mv Carrillo León, Julián and González Peñuela, Noel Giovanni and Llano Sanchez, Luis (2012) Evaluation of mass-rig systems for shaking table experiments. Dyna; Vol. 79, núm. 176 (2012); 159-167 DYNA; Vol. 79, núm. 176 (2012); 159-167 2346-2183 0012-7353 .
dc.rights.spa.fl_str_mv Derechos reservados - Universidad Nacional de Colombia
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.license.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional
dc.rights.uri.spa.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv Atribución-NoComercial 4.0 Internacional
Derechos reservados - Universidad Nacional de Colombia
http://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Nacional de Colombia Sede Medellín
institution Universidad Nacional de Colombia
bitstream.url.fl_str_mv https://repositorio.unal.edu.co/bitstream/unal/39731/1/28509-191462-1-PB.html
https://repositorio.unal.edu.co/bitstream/unal/39731/2/28509-102049-1-SP.pdf
https://repositorio.unal.edu.co/bitstream/unal/39731/3/28509-151109-1-PB.pdf
https://repositorio.unal.edu.co/bitstream/unal/39731/4/28509-102049-1-SP.pdf.jpg
https://repositorio.unal.edu.co/bitstream/unal/39731/5/28509-151109-1-PB.pdf.jpg
bitstream.checksum.fl_str_mv e40cb9c57d386d449470f9c7a04fe540
f6fec271d7bc3532231253caf96e1e5d
84f44d83223666a1d8c3e62bbf69a2c0
cf4ea8eac02d001a315586fa315a5f54
d1e07b40488e66aed3a0195c35394880
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad Nacional de Colombia
repository.mail.fl_str_mv repositorio_nal@unal.edu.co
_version_ 1814089292495978496