Two-dimensional computational modeling of the electrokinetic remediation of a copper-contaminated soil part ii: sensitivity analysis for a triangular soil field

The computer model described in the first paper of this series was used to perform a sensitivity analysis for the electrokinetic remediation of a triangular, copper-contaminated soil field in which one anode and two cathodes are placed in the vicinity of the triangle vertices. The input variables in...

Full description

Autores:
Rubio Nieblas, Virgilio
Pérez Tello, Manuel
Jacobs, Richard A.
Herrara Urbina, Ronaldo
Tipo de recurso:
Article of journal
Fecha de publicación:
2014
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/71848
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/71848
http://bdigital.unal.edu.co/36320/
Palabra clave:
Two-dimensional
mathematical model
electrokinetics
sensitivity analysis
Rights
openAccess
License
Atribución-NoComercial 4.0 Internacional
id UNACIONAL2_67f7b27aa710b14d019ebc00af6b3988
oai_identifier_str oai:repositorio.unal.edu.co:unal/71848
network_acronym_str UNACIONAL2
network_name_str Universidad Nacional de Colombia
repository_id_str
spelling Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Rubio Nieblas, Virgilioae979346-df2c-4232-8644-70e5f96bfbf6300Pérez Tello, Manuelc8add787-59c6-499e-86be-d06c72243633300Jacobs, Richard A.a2581da6-6b72-4a6b-8dbe-817451c241f0300Herrara Urbina, Ronaldo620d5ff7-0a80-41d1-bbb6-54cd1c1ff2bf3002019-07-03T14:41:09Z2019-07-03T14:41:09Z2014-01-22https://repositorio.unal.edu.co/handle/unal/71848http://bdigital.unal.edu.co/36320/The computer model described in the first paper of this series was used to perform a sensitivity analysis for the electrokinetic remediation of a triangular, copper-contaminated soil field in which one anode and two cathodes are placed in the vicinity of the triangle vertices. The input variables included the initial concentration of copper in the soil , the electrical potential applied between electrodes, and the absence or presence of wash water. The output variables included the cleanup efficiency and the fraction of copper eliminated from the soil fCu. Overall, the larger the electrical potential applied between electrodes, the shorter the time to achieve steady state. When no wash water is used, the cleanup efficiency may fluctuate over time before reaching steady state. When wash water is used, the final fCu obtained depends on the initial concentration of copper in the soil.application/pdfspaUniversidad Nacional de Colombia Sede Medellínhttp://revistas.unal.edu.co/index.php/dyna/article/view/36909Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaDYNA; Vol. 81, núm. 183 (2014); 208-214 Dyna; Vol. 81, núm. 183 (2014); 208-214 2346-2183 0012-7353Rubio Nieblas, Virgilio and Pérez Tello, Manuel and Jacobs, Richard A. and Herrara Urbina, Ronaldo (2014) Two-dimensional computational modeling of the electrokinetic remediation of a copper-contaminated soil part ii: sensitivity analysis for a triangular soil field. DYNA; Vol. 81, núm. 183 (2014); 208-214 Dyna; Vol. 81, núm. 183 (2014); 208-214 2346-2183 0012-7353 .Two-dimensional computational modeling of the electrokinetic remediation of a copper-contaminated soil part ii: sensitivity analysis for a triangular soil fieldArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTTwo-dimensionalmathematical modelelectrokineticssensitivity analysisORIGINAL36909-155986-1-SP.pdfapplication/pdf30919https://repositorio.unal.edu.co/bitstream/unal/71848/1/36909-155986-1-SP.pdf999e963d0e8e5dcb4676d3c45157c52dMD5136909-194765-1-PB.pdfapplication/pdf485418https://repositorio.unal.edu.co/bitstream/unal/71848/2/36909-194765-1-PB.pdfad7bac599ca0f2ab58fa83baf3519080MD52THUMBNAIL36909-155986-1-SP.pdf.jpg36909-155986-1-SP.pdf.jpgGenerated Thumbnailimage/jpeg7821https://repositorio.unal.edu.co/bitstream/unal/71848/3/36909-155986-1-SP.pdf.jpgd59bf6d31077b2020156625a85350af6MD5336909-194765-1-PB.pdf.jpg36909-194765-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg9167https://repositorio.unal.edu.co/bitstream/unal/71848/4/36909-194765-1-PB.pdf.jpg82e46ea88f4be4f4734ad0aca87b4a55MD54unal/71848oai:repositorio.unal.edu.co:unal/718482023-06-20 23:03:22.146Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co
dc.title.spa.fl_str_mv Two-dimensional computational modeling of the electrokinetic remediation of a copper-contaminated soil part ii: sensitivity analysis for a triangular soil field
title Two-dimensional computational modeling of the electrokinetic remediation of a copper-contaminated soil part ii: sensitivity analysis for a triangular soil field
spellingShingle Two-dimensional computational modeling of the electrokinetic remediation of a copper-contaminated soil part ii: sensitivity analysis for a triangular soil field
Two-dimensional
mathematical model
electrokinetics
sensitivity analysis
title_short Two-dimensional computational modeling of the electrokinetic remediation of a copper-contaminated soil part ii: sensitivity analysis for a triangular soil field
title_full Two-dimensional computational modeling of the electrokinetic remediation of a copper-contaminated soil part ii: sensitivity analysis for a triangular soil field
title_fullStr Two-dimensional computational modeling of the electrokinetic remediation of a copper-contaminated soil part ii: sensitivity analysis for a triangular soil field
title_full_unstemmed Two-dimensional computational modeling of the electrokinetic remediation of a copper-contaminated soil part ii: sensitivity analysis for a triangular soil field
title_sort Two-dimensional computational modeling of the electrokinetic remediation of a copper-contaminated soil part ii: sensitivity analysis for a triangular soil field
dc.creator.fl_str_mv Rubio Nieblas, Virgilio
Pérez Tello, Manuel
Jacobs, Richard A.
Herrara Urbina, Ronaldo
dc.contributor.author.spa.fl_str_mv Rubio Nieblas, Virgilio
Pérez Tello, Manuel
Jacobs, Richard A.
Herrara Urbina, Ronaldo
dc.subject.proposal.spa.fl_str_mv Two-dimensional
mathematical model
electrokinetics
sensitivity analysis
topic Two-dimensional
mathematical model
electrokinetics
sensitivity analysis
description The computer model described in the first paper of this series was used to perform a sensitivity analysis for the electrokinetic remediation of a triangular, copper-contaminated soil field in which one anode and two cathodes are placed in the vicinity of the triangle vertices. The input variables included the initial concentration of copper in the soil , the electrical potential applied between electrodes, and the absence or presence of wash water. The output variables included the cleanup efficiency and the fraction of copper eliminated from the soil fCu. Overall, the larger the electrical potential applied between electrodes, the shorter the time to achieve steady state. When no wash water is used, the cleanup efficiency may fluctuate over time before reaching steady state. When wash water is used, the final fCu obtained depends on the initial concentration of copper in the soil.
publishDate 2014
dc.date.issued.spa.fl_str_mv 2014-01-22
dc.date.accessioned.spa.fl_str_mv 2019-07-03T14:41:09Z
dc.date.available.spa.fl_str_mv 2019-07-03T14:41:09Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.uri.none.fl_str_mv https://repositorio.unal.edu.co/handle/unal/71848
dc.identifier.eprints.spa.fl_str_mv http://bdigital.unal.edu.co/36320/
url https://repositorio.unal.edu.co/handle/unal/71848
http://bdigital.unal.edu.co/36320/
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv http://revistas.unal.edu.co/index.php/dyna/article/view/36909
dc.relation.ispartof.spa.fl_str_mv Universidad Nacional de Colombia Revistas electrónicas UN Dyna
Dyna
dc.relation.ispartofseries.none.fl_str_mv DYNA; Vol. 81, núm. 183 (2014); 208-214 Dyna; Vol. 81, núm. 183 (2014); 208-214 2346-2183 0012-7353
dc.relation.references.spa.fl_str_mv Rubio Nieblas, Virgilio and Pérez Tello, Manuel and Jacobs, Richard A. and Herrara Urbina, Ronaldo (2014) Two-dimensional computational modeling of the electrokinetic remediation of a copper-contaminated soil part ii: sensitivity analysis for a triangular soil field. DYNA; Vol. 81, núm. 183 (2014); 208-214 Dyna; Vol. 81, núm. 183 (2014); 208-214 2346-2183 0012-7353 .
dc.rights.spa.fl_str_mv Derechos reservados - Universidad Nacional de Colombia
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.license.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional
dc.rights.uri.spa.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv Atribución-NoComercial 4.0 Internacional
Derechos reservados - Universidad Nacional de Colombia
http://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Nacional de Colombia Sede Medellín
institution Universidad Nacional de Colombia
bitstream.url.fl_str_mv https://repositorio.unal.edu.co/bitstream/unal/71848/1/36909-155986-1-SP.pdf
https://repositorio.unal.edu.co/bitstream/unal/71848/2/36909-194765-1-PB.pdf
https://repositorio.unal.edu.co/bitstream/unal/71848/3/36909-155986-1-SP.pdf.jpg
https://repositorio.unal.edu.co/bitstream/unal/71848/4/36909-194765-1-PB.pdf.jpg
bitstream.checksum.fl_str_mv 999e963d0e8e5dcb4676d3c45157c52d
ad7bac599ca0f2ab58fa83baf3519080
d59bf6d31077b2020156625a85350af6
82e46ea88f4be4f4734ad0aca87b4a55
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad Nacional de Colombia
repository.mail.fl_str_mv repositorio_nal@unal.edu.co
_version_ 1814089536117932032