Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion
Human movement analysis have become fundamental for a wide range of applications, such as physical therapies, neuro-rehabilitation, sports medicine, human motor system performance assessment and occupational medicine. This paper focuses on the design, implementation and validation of an inertial sen...
- Autores:
-
Ruiz-Olaya, Andrés F.
Callejas-Cuervo, Mauro
Lara-Herrera, Claudia N.
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2017
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/60396
- Acceso en línea:
- https://repositorio.unal.edu.co/handle/unal/60396
http://bdigital.unal.edu.co/58728/
- Palabra clave:
- 62 Ingeniería y operaciones afines / Engineering
Electrogoniometer
inertial sensors
joint range of motion
motion capture system
Electrogoniómetro
sensores inerciales
rango articular de movimiento
sistema de captura de movimiento
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional
id |
UNACIONAL2_59d9c2b2d5d7d7ee726ff1bbf6363db3 |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/60396 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
spelling |
Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Ruiz-Olaya, Andrés F.16b60a64-b3ea-4cc3-bdb2-61d42a18c0dc300Callejas-Cuervo, Mauroc3034397-0384-4c8d-ae2c-f81956aca5f7300Lara-Herrera, Claudia N.35d428fa-b62e-41e2-893a-bff497ebe7903002019-07-02T18:13:19Z2019-07-02T18:13:19Z2017-04-01ISSN: 2346-2183https://repositorio.unal.edu.co/handle/unal/60396http://bdigital.unal.edu.co/58728/Human movement analysis have become fundamental for a wide range of applications, such as physical therapies, neuro-rehabilitation, sports medicine, human motor system performance assessment and occupational medicine. This paper focuses on the design, implementation and validation of an inertial sensor-based portable electrogoniometer aimed at measuring joint range of motion. The system is composed of two inertial measurement units and a microcontroller that permits real-time human motion capture. The electrogoniometer was tested both in static and dynamic conditions in comparison to a standard commercial electrogoniometer during elbow movements. For static validation, the concordance correlation coefficient (ρC) obtained was 0.9605. The ρC found for slow-speed cyclical movements was 0.9830 and the ρC found for moderate-speed cyclical movements was 0.9619.El análisis del movimiento humano ha llegado a ser fundamental para una amplia gama de aplicaciones, tales como terapias físicas, neuro-rehabilitación, medicina deportiva, la evaluación de la funcionalidad del sistema motor y la medicina del trabajo. Este artículo se centra en el diseño, implementación y validación de un electrogoniómetro portátil basado en sensores inerciales y magnéticos para la adquisición del rango articular de movimiento. El sistema se compone de dos unidades de medición inercial y un microcontrolador que permite la captura de movimiento humano en tiempo real. El electrogoniómetro se validó tanto en condiciones estáticas como dinámicas, en comparación con un electrogoniómetro estándar comercial para movimientos de la articulación del codo. Para validación estática, el coeficiente de correlación de concordancia (ρC) obtenido fue 0.9605. El ρC obtenido para los movimientos cíclicos de baja velocidad fue 0.9830 y el ρC obtenido para los movimientos cíclicos de velocidad moderada fue 0.9619.application/pdfspaUniversidad Nacional de Colombia (Sede Medellín). Facultad de Minas.https://revistas.unal.edu.co/index.php/dyna/article/view/59054Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaRuiz-Olaya, Andrés F. and Callejas-Cuervo, Mauro and Lara-Herrera, Claudia N. (2017) Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion. DYNA, 84 (201). pp. 180-185. ISSN 2346-218362 Ingeniería y operaciones afines / EngineeringElectrogoniometerinertial sensorsjoint range of motionmotion capture systemElectrogoniómetrosensores inercialesrango articular de movimientosistema de captura de movimientoWearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motionArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL59054-333136-1-PB.pdfapplication/pdf794674https://repositorio.unal.edu.co/bitstream/unal/60396/1/59054-333136-1-PB.pdf1cc97c9f897473fb346597075b2d39b0MD51THUMBNAIL59054-333136-1-PB.pdf.jpg59054-333136-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg9808https://repositorio.unal.edu.co/bitstream/unal/60396/2/59054-333136-1-PB.pdf.jpgb79fef81924cb0a7b5721c2bfb78da1eMD52unal/60396oai:repositorio.unal.edu.co:unal/603962024-04-13 23:10:25.143Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co |
dc.title.spa.fl_str_mv |
Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion |
title |
Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion |
spellingShingle |
Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion 62 Ingeniería y operaciones afines / Engineering Electrogoniometer inertial sensors joint range of motion motion capture system Electrogoniómetro sensores inerciales rango articular de movimiento sistema de captura de movimiento |
title_short |
Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion |
title_full |
Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion |
title_fullStr |
Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion |
title_full_unstemmed |
Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion |
title_sort |
Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion |
dc.creator.fl_str_mv |
Ruiz-Olaya, Andrés F. Callejas-Cuervo, Mauro Lara-Herrera, Claudia N. |
dc.contributor.author.spa.fl_str_mv |
Ruiz-Olaya, Andrés F. Callejas-Cuervo, Mauro Lara-Herrera, Claudia N. |
dc.subject.ddc.spa.fl_str_mv |
62 Ingeniería y operaciones afines / Engineering |
topic |
62 Ingeniería y operaciones afines / Engineering Electrogoniometer inertial sensors joint range of motion motion capture system Electrogoniómetro sensores inerciales rango articular de movimiento sistema de captura de movimiento |
dc.subject.proposal.spa.fl_str_mv |
Electrogoniometer inertial sensors joint range of motion motion capture system Electrogoniómetro sensores inerciales rango articular de movimiento sistema de captura de movimiento |
description |
Human movement analysis have become fundamental for a wide range of applications, such as physical therapies, neuro-rehabilitation, sports medicine, human motor system performance assessment and occupational medicine. This paper focuses on the design, implementation and validation of an inertial sensor-based portable electrogoniometer aimed at measuring joint range of motion. The system is composed of two inertial measurement units and a microcontroller that permits real-time human motion capture. The electrogoniometer was tested both in static and dynamic conditions in comparison to a standard commercial electrogoniometer during elbow movements. For static validation, the concordance correlation coefficient (ρC) obtained was 0.9605. The ρC found for slow-speed cyclical movements was 0.9830 and the ρC found for moderate-speed cyclical movements was 0.9619. |
publishDate |
2017 |
dc.date.issued.spa.fl_str_mv |
2017-04-01 |
dc.date.accessioned.spa.fl_str_mv |
2019-07-02T18:13:19Z |
dc.date.available.spa.fl_str_mv |
2019-07-02T18:13:19Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.coarversion.spa.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.issn.spa.fl_str_mv |
ISSN: 2346-2183 |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/60396 |
dc.identifier.eprints.spa.fl_str_mv |
http://bdigital.unal.edu.co/58728/ |
identifier_str_mv |
ISSN: 2346-2183 |
url |
https://repositorio.unal.edu.co/handle/unal/60396 http://bdigital.unal.edu.co/58728/ |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.spa.fl_str_mv |
https://revistas.unal.edu.co/index.php/dyna/article/view/59054 |
dc.relation.ispartof.spa.fl_str_mv |
Universidad Nacional de Colombia Revistas electrónicas UN Dyna Dyna |
dc.relation.references.spa.fl_str_mv |
Ruiz-Olaya, Andrés F. and Callejas-Cuervo, Mauro and Lara-Herrera, Claudia N. (2017) Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion. DYNA, 84 (201). pp. 180-185. ISSN 2346-2183 |
dc.rights.spa.fl_str_mv |
Derechos reservados - Universidad Nacional de Colombia |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial 4.0 Internacional Derechos reservados - Universidad Nacional de Colombia http://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Universidad Nacional de Colombia (Sede Medellín). Facultad de Minas. |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/60396/1/59054-333136-1-PB.pdf https://repositorio.unal.edu.co/bitstream/unal/60396/2/59054-333136-1-PB.pdf.jpg |
bitstream.checksum.fl_str_mv |
1cc97c9f897473fb346597075b2d39b0 b79fef81924cb0a7b5721c2bfb78da1e |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814090130591318016 |