Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion

Human movement analysis have become fundamental for a wide range of applications, such as physical therapies, neuro-rehabilitation, sports medicine, human motor system performance assessment and occupational medicine. This paper focuses on the design, implementation and validation of an inertial sen...

Full description

Autores:
Ruiz-Olaya, Andrés F.
Callejas-Cuervo, Mauro
Lara-Herrera, Claudia N.
Tipo de recurso:
Article of journal
Fecha de publicación:
2017
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/60396
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/60396
http://bdigital.unal.edu.co/58728/
Palabra clave:
62 Ingeniería y operaciones afines / Engineering
Electrogoniometer
inertial sensors
joint range of motion
motion capture system
Electrogoniómetro
sensores inerciales
rango articular de movimiento
sistema de captura de movimiento
Rights
openAccess
License
Atribución-NoComercial 4.0 Internacional
id UNACIONAL2_59d9c2b2d5d7d7ee726ff1bbf6363db3
oai_identifier_str oai:repositorio.unal.edu.co:unal/60396
network_acronym_str UNACIONAL2
network_name_str Universidad Nacional de Colombia
repository_id_str
spelling Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Ruiz-Olaya, Andrés F.16b60a64-b3ea-4cc3-bdb2-61d42a18c0dc300Callejas-Cuervo, Mauroc3034397-0384-4c8d-ae2c-f81956aca5f7300Lara-Herrera, Claudia N.35d428fa-b62e-41e2-893a-bff497ebe7903002019-07-02T18:13:19Z2019-07-02T18:13:19Z2017-04-01ISSN: 2346-2183https://repositorio.unal.edu.co/handle/unal/60396http://bdigital.unal.edu.co/58728/Human movement analysis have become fundamental for a wide range of applications, such as physical therapies, neuro-rehabilitation, sports medicine, human motor system performance assessment and occupational medicine. This paper focuses on the design, implementation and validation of an inertial sensor-based portable electrogoniometer aimed at measuring joint range of motion. The system is composed of two inertial measurement units and a microcontroller that permits real-time human motion capture. The electrogoniometer was tested both in static and dynamic conditions in comparison to a standard commercial electrogoniometer during elbow movements. For static validation, the concordance correlation coefficient (ρC) obtained was 0.9605. The ρC found for slow-speed cyclical movements was 0.9830 and the ρC found for moderate-speed cyclical movements was 0.9619.El análisis del movimiento humano ha llegado a ser fundamental para una amplia gama de aplicaciones, tales como terapias físicas, neuro-rehabilitación, medicina deportiva, la evaluación de la funcionalidad del sistema motor y la medicina del trabajo. Este artículo se centra en el diseño, implementación y validación de un electrogoniómetro portátil basado en sensores inerciales y magnéticos para la adquisición del rango articular de movimiento. El sistema se compone de dos unidades de medición inercial y un microcontrolador que permite la captura de movimiento humano en tiempo real. El electrogoniómetro se validó tanto en condiciones estáticas como dinámicas, en comparación con un electrogoniómetro estándar comercial para movimientos de la articulación del codo. Para validación estática, el coeficiente de correlación de concordancia (ρC) obtenido fue 0.9605. El ρC obtenido para los movimientos cíclicos de baja velocidad fue 0.9830 y el ρC obtenido para los movimientos cíclicos de velocidad moderada fue 0.9619.application/pdfspaUniversidad Nacional de Colombia (Sede Medellín). Facultad de Minas.https://revistas.unal.edu.co/index.php/dyna/article/view/59054Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaRuiz-Olaya, Andrés F. and Callejas-Cuervo, Mauro and Lara-Herrera, Claudia N. (2017) Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion. DYNA, 84 (201). pp. 180-185. ISSN 2346-218362 Ingeniería y operaciones afines / EngineeringElectrogoniometerinertial sensorsjoint range of motionmotion capture systemElectrogoniómetrosensores inercialesrango articular de movimientosistema de captura de movimientoWearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motionArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL59054-333136-1-PB.pdfapplication/pdf794674https://repositorio.unal.edu.co/bitstream/unal/60396/1/59054-333136-1-PB.pdf1cc97c9f897473fb346597075b2d39b0MD51THUMBNAIL59054-333136-1-PB.pdf.jpg59054-333136-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg9808https://repositorio.unal.edu.co/bitstream/unal/60396/2/59054-333136-1-PB.pdf.jpgb79fef81924cb0a7b5721c2bfb78da1eMD52unal/60396oai:repositorio.unal.edu.co:unal/603962024-04-13 23:10:25.143Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co
dc.title.spa.fl_str_mv Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion
title Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion
spellingShingle Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion
62 Ingeniería y operaciones afines / Engineering
Electrogoniometer
inertial sensors
joint range of motion
motion capture system
Electrogoniómetro
sensores inerciales
rango articular de movimiento
sistema de captura de movimiento
title_short Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion
title_full Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion
title_fullStr Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion
title_full_unstemmed Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion
title_sort Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion
dc.creator.fl_str_mv Ruiz-Olaya, Andrés F.
Callejas-Cuervo, Mauro
Lara-Herrera, Claudia N.
dc.contributor.author.spa.fl_str_mv Ruiz-Olaya, Andrés F.
Callejas-Cuervo, Mauro
Lara-Herrera, Claudia N.
dc.subject.ddc.spa.fl_str_mv 62 Ingeniería y operaciones afines / Engineering
topic 62 Ingeniería y operaciones afines / Engineering
Electrogoniometer
inertial sensors
joint range of motion
motion capture system
Electrogoniómetro
sensores inerciales
rango articular de movimiento
sistema de captura de movimiento
dc.subject.proposal.spa.fl_str_mv Electrogoniometer
inertial sensors
joint range of motion
motion capture system
Electrogoniómetro
sensores inerciales
rango articular de movimiento
sistema de captura de movimiento
description Human movement analysis have become fundamental for a wide range of applications, such as physical therapies, neuro-rehabilitation, sports medicine, human motor system performance assessment and occupational medicine. This paper focuses on the design, implementation and validation of an inertial sensor-based portable electrogoniometer aimed at measuring joint range of motion. The system is composed of two inertial measurement units and a microcontroller that permits real-time human motion capture. The electrogoniometer was tested both in static and dynamic conditions in comparison to a standard commercial electrogoniometer during elbow movements. For static validation, the concordance correlation coefficient (ρC) obtained was 0.9605. The ρC found for slow-speed cyclical movements was 0.9830 and the ρC found for moderate-speed cyclical movements was 0.9619.
publishDate 2017
dc.date.issued.spa.fl_str_mv 2017-04-01
dc.date.accessioned.spa.fl_str_mv 2019-07-02T18:13:19Z
dc.date.available.spa.fl_str_mv 2019-07-02T18:13:19Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.issn.spa.fl_str_mv ISSN: 2346-2183
dc.identifier.uri.none.fl_str_mv https://repositorio.unal.edu.co/handle/unal/60396
dc.identifier.eprints.spa.fl_str_mv http://bdigital.unal.edu.co/58728/
identifier_str_mv ISSN: 2346-2183
url https://repositorio.unal.edu.co/handle/unal/60396
http://bdigital.unal.edu.co/58728/
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv https://revistas.unal.edu.co/index.php/dyna/article/view/59054
dc.relation.ispartof.spa.fl_str_mv Universidad Nacional de Colombia Revistas electrónicas UN Dyna
Dyna
dc.relation.references.spa.fl_str_mv Ruiz-Olaya, Andrés F. and Callejas-Cuervo, Mauro and Lara-Herrera, Claudia N. (2017) Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion. DYNA, 84 (201). pp. 180-185. ISSN 2346-2183
dc.rights.spa.fl_str_mv Derechos reservados - Universidad Nacional de Colombia
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.license.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional
dc.rights.uri.spa.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv Atribución-NoComercial 4.0 Internacional
Derechos reservados - Universidad Nacional de Colombia
http://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Nacional de Colombia (Sede Medellín). Facultad de Minas.
institution Universidad Nacional de Colombia
bitstream.url.fl_str_mv https://repositorio.unal.edu.co/bitstream/unal/60396/1/59054-333136-1-PB.pdf
https://repositorio.unal.edu.co/bitstream/unal/60396/2/59054-333136-1-PB.pdf.jpg
bitstream.checksum.fl_str_mv 1cc97c9f897473fb346597075b2d39b0
b79fef81924cb0a7b5721c2bfb78da1e
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad Nacional de Colombia
repository.mail.fl_str_mv repositorio_nal@unal.edu.co
_version_ 1814090130591318016