Influence of moist air in copper heat sinks: Analysis through the entropy generation minimization criterion
Many factors affect heat transfer during the cooling of modern electronic devices. Today, knowledge accrues from modeling, simu-lation, and experimentation. This allows predicting and calculating features of heat transfer phenomena, to some extent. Examples include the amount of heat generated and r...
- Autores:
-
Cruz, Jorge Mario
Amaya, Iván Mauricio
Correa, Carlos Rodrigo
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2015
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/67643
- Acceso en línea:
- https://repositorio.unal.edu.co/handle/unal/67643
http://bdigital.unal.edu.co/68672/
- Palabra clave:
- 62 Ingeniería y operaciones afines / Engineering
Heat sinks
microelectronics
global optimization
entropy generation minimization
moist air.
Disipadores de calor
microelectrónica
optimización global
mínima generación de entropía
aire húmedo.
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional
id |
UNACIONAL2_57dbf7bf401d8a69f1dad2a3b96064f0 |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/67643 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
dc.title.spa.fl_str_mv |
Influence of moist air in copper heat sinks: Analysis through the entropy generation minimization criterion |
title |
Influence of moist air in copper heat sinks: Analysis through the entropy generation minimization criterion |
spellingShingle |
Influence of moist air in copper heat sinks: Analysis through the entropy generation minimization criterion 62 Ingeniería y operaciones afines / Engineering Heat sinks microelectronics global optimization entropy generation minimization moist air. Disipadores de calor microelectrónica optimización global mínima generación de entropía aire húmedo. |
title_short |
Influence of moist air in copper heat sinks: Analysis through the entropy generation minimization criterion |
title_full |
Influence of moist air in copper heat sinks: Analysis through the entropy generation minimization criterion |
title_fullStr |
Influence of moist air in copper heat sinks: Analysis through the entropy generation minimization criterion |
title_full_unstemmed |
Influence of moist air in copper heat sinks: Analysis through the entropy generation minimization criterion |
title_sort |
Influence of moist air in copper heat sinks: Analysis through the entropy generation minimization criterion |
dc.creator.fl_str_mv |
Cruz, Jorge Mario Amaya, Iván Mauricio Correa, Carlos Rodrigo |
dc.contributor.author.spa.fl_str_mv |
Cruz, Jorge Mario Amaya, Iván Mauricio Correa, Carlos Rodrigo |
dc.subject.ddc.spa.fl_str_mv |
62 Ingeniería y operaciones afines / Engineering |
topic |
62 Ingeniería y operaciones afines / Engineering Heat sinks microelectronics global optimization entropy generation minimization moist air. Disipadores de calor microelectrónica optimización global mínima generación de entropía aire húmedo. |
dc.subject.proposal.spa.fl_str_mv |
Heat sinks microelectronics global optimization entropy generation minimization moist air. Disipadores de calor microelectrónica optimización global mínima generación de entropía aire húmedo. |
description |
Many factors affect heat transfer during the cooling of modern electronic devices. Today, knowledge accrues from modeling, simu-lation, and experimentation. This allows predicting and calculating features of heat transfer phenomena, to some extent. Examples include the amount of heat generated and removed, the required physical properties of the working fluid, and the required material properties of the heat sink, among other parameters. This article describes some simulation results of using air with a given relative humidity (10 %, 50 % and 90 %). Its influence on the heat transfer process was also analyzed. Results show a measurable effect of using humidified air instead of dry air and copper as a bulk material. The heat transfer rate increased about 20 % when using air with 90 % relative humidity passing through a rectangular microchannel heat sink made of copper. |
publishDate |
2015 |
dc.date.issued.spa.fl_str_mv |
2015-09-01 |
dc.date.accessioned.spa.fl_str_mv |
2019-07-03T04:45:07Z |
dc.date.available.spa.fl_str_mv |
2019-07-03T04:45:07Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.coarversion.spa.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.issn.spa.fl_str_mv |
ISSN: 2248-8723 |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/67643 |
dc.identifier.eprints.spa.fl_str_mv |
http://bdigital.unal.edu.co/68672/ |
identifier_str_mv |
ISSN: 2248-8723 |
url |
https://repositorio.unal.edu.co/handle/unal/67643 http://bdigital.unal.edu.co/68672/ |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.spa.fl_str_mv |
https://revistas.unal.edu.co/index.php/ingeinv/article/view/49623 |
dc.relation.ispartof.spa.fl_str_mv |
Universidad Nacional de Colombia Revistas electrónicas UN Ingeniería e Investigación Ingeniería e Investigación |
dc.relation.references.spa.fl_str_mv |
Cruz, Jorge Mario and Amaya, Iván Mauricio and Correa, Carlos Rodrigo (2015) Influence of moist air in copper heat sinks: Analysis through the entropy generation minimization criterion. Ingeniería e Investigación, 35 (3). pp. 44-52. ISSN 2248-8723 |
dc.rights.spa.fl_str_mv |
Derechos reservados - Universidad Nacional de Colombia |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial 4.0 Internacional Derechos reservados - Universidad Nacional de Colombia http://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Universidad Nacional de Colombia - Sede Bogotá - Facultad de Ingeniería |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/67643/1/49623-276922-1-PB.pdf https://repositorio.unal.edu.co/bitstream/unal/67643/2/49623-276922-1-PB.pdf.jpg |
bitstream.checksum.fl_str_mv |
2f169da5e3412175c627bee274117b06 1d4c818499b88ccaba5dbe21876880a9 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814089953899970560 |
spelling |
Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Cruz, Jorge Marioa77a9059-0b99-44f5-be33-f5a6733c6a48300Amaya, Iván Mauricio43171af7-814e-4c46-851a-014f93849005300Correa, Carlos Rodrigo5e17a6a6-f635-4083-a277-4537f3e0821e3002019-07-03T04:45:07Z2019-07-03T04:45:07Z2015-09-01ISSN: 2248-8723https://repositorio.unal.edu.co/handle/unal/67643http://bdigital.unal.edu.co/68672/Many factors affect heat transfer during the cooling of modern electronic devices. Today, knowledge accrues from modeling, simu-lation, and experimentation. This allows predicting and calculating features of heat transfer phenomena, to some extent. Examples include the amount of heat generated and removed, the required physical properties of the working fluid, and the required material properties of the heat sink, among other parameters. This article describes some simulation results of using air with a given relative humidity (10 %, 50 % and 90 %). Its influence on the heat transfer process was also analyzed. Results show a measurable effect of using humidified air instead of dry air and copper as a bulk material. The heat transfer rate increased about 20 % when using air with 90 % relative humidity passing through a rectangular microchannel heat sink made of copper.Son muchos los factores que afectan la transferencia de calor durante el enfriamiento de los dispositivos electrónicos modernos. En la actualidad, el conocimiento acumulado proviene del modelado, la simulación, y la experimentación. Esto permite predecir y calcular características de fenómenos de transferencia de calor, hasta cierto punto. Ejemplos de ello incluyen la cantidad de calor generado y removido, las propiedades físicas necesarias para un fluido de trabajo, y las propiedades requeridas para el material de un disipador de calor, entre otros parámetros. Este artículo describe algunos resultados de simulación utilizando aire con un valor de humedad relativa dado (10, 50 y 90 %). Su influencia en el proceso de transferencia de calor también fue analizado. Los resultados muestran un efecto medible del uso de aire humedecido en lugar del aire seco y del cobre como material del disipador. La tasa de transferencia de calor incrementó alrededor de 20 %, utilizando aire con 90 % de humedad relativa que atraviesa un disipador de calor de microcanales rectangulares hecho de cobre.application/pdfspaUniversidad Nacional de Colombia - Sede Bogotá - Facultad de Ingenieríahttps://revistas.unal.edu.co/index.php/ingeinv/article/view/49623Universidad Nacional de Colombia Revistas electrónicas UN Ingeniería e InvestigaciónIngeniería e InvestigaciónCruz, Jorge Mario and Amaya, Iván Mauricio and Correa, Carlos Rodrigo (2015) Influence of moist air in copper heat sinks: Analysis through the entropy generation minimization criterion. Ingeniería e Investigación, 35 (3). pp. 44-52. ISSN 2248-872362 Ingeniería y operaciones afines / EngineeringHeat sinksmicroelectronicsglobal optimizationentropy generation minimizationmoist air.Disipadores de calormicroelectrónicaoptimización globalmínima generación de entropíaaire húmedo.Influence of moist air in copper heat sinks: Analysis through the entropy generation minimization criterionArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL49623-276922-1-PB.pdfapplication/pdf1531697https://repositorio.unal.edu.co/bitstream/unal/67643/1/49623-276922-1-PB.pdf2f169da5e3412175c627bee274117b06MD51THUMBNAIL49623-276922-1-PB.pdf.jpg49623-276922-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg8858https://repositorio.unal.edu.co/bitstream/unal/67643/2/49623-276922-1-PB.pdf.jpg1d4c818499b88ccaba5dbe21876880a9MD52unal/67643oai:repositorio.unal.edu.co:unal/676432024-05-22 23:34:06.574Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co |