Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. Nevertheless, the derivation of this model...
- Autores:
-
Malagon, Gabriel Alexis
Bello Peña, Jeisson
Ordóñez Plata, Gabriel
Duarte Gualdrón, Cesar
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2015
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/67658
- Acceso en línea:
- https://repositorio.unal.edu.co/handle/unal/67658
http://bdigital.unal.edu.co/68687/
- Palabra clave:
- 62 Ingeniería y operaciones afines / Engineering
CFL circuit-based model
harmonics attenuation
harmonics diversity
harmonic load modelling.
Modelo circuital CFL
atenuación de armónicos
diversidad de armónicos
modelos de carga armónica.
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional
id |
UNACIONAL2_2b495fd5613877f4acf68ea12b7959e7 |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/67658 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
dc.title.spa.fl_str_mv |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid |
title |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid |
spellingShingle |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid 62 Ingeniería y operaciones afines / Engineering CFL circuit-based model harmonics attenuation harmonics diversity harmonic load modelling. Modelo circuital CFL atenuación de armónicos diversidad de armónicos modelos de carga armónica. |
title_short |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid |
title_full |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid |
title_fullStr |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid |
title_full_unstemmed |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid |
title_sort |
Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid |
dc.creator.fl_str_mv |
Malagon, Gabriel Alexis Bello Peña, Jeisson Ordóñez Plata, Gabriel Duarte Gualdrón, Cesar |
dc.contributor.author.spa.fl_str_mv |
Malagon, Gabriel Alexis Bello Peña, Jeisson Ordóñez Plata, Gabriel Duarte Gualdrón, Cesar |
dc.subject.ddc.spa.fl_str_mv |
62 Ingeniería y operaciones afines / Engineering |
topic |
62 Ingeniería y operaciones afines / Engineering CFL circuit-based model harmonics attenuation harmonics diversity harmonic load modelling. Modelo circuital CFL atenuación de armónicos diversidad de armónicos modelos de carga armónica. |
dc.subject.proposal.spa.fl_str_mv |
CFL circuit-based model harmonics attenuation harmonics diversity harmonic load modelling. Modelo circuital CFL atenuación de armónicos diversidad de armónicos modelos de carga armónica. |
description |
This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. Nevertheless, the derivation of this model is not straightforward to follow and its performance in 120V 60Hz systems is a matter of research work. In this paper, the analytical derivation of this CFL model is presented in detail and its performance is discussed when predicting the current of a CFL designed to operate in a 120V 60Hz electrical system. The derived model is separately implemented in both MATLAB® and ATP-EMTP® software using two different sets of parameters previously proposed for 230V 50Hz CFLs. These simulation results are compared against laboratory measurements using a programmable AC voltage source. The measurements and simulations considered seven CFLs 110/127V 60Hz with different power ratings supplied by a sinusoidal (not distorted) voltage source. The simulations under these conditions do not properly predict the current measurements and therefore the set of parameters and/or the model itself need to be adjusted for 120V 60Hz power grids. |
publishDate |
2015 |
dc.date.issued.spa.fl_str_mv |
2015-06-01 |
dc.date.accessioned.spa.fl_str_mv |
2019-07-03T04:47:20Z |
dc.date.available.spa.fl_str_mv |
2019-07-03T04:47:20Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.coarversion.spa.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.issn.spa.fl_str_mv |
ISSN: 2248-8723 |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/67658 |
dc.identifier.eprints.spa.fl_str_mv |
http://bdigital.unal.edu.co/68687/ |
identifier_str_mv |
ISSN: 2248-8723 |
url |
https://repositorio.unal.edu.co/handle/unal/67658 http://bdigital.unal.edu.co/68687/ |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.spa.fl_str_mv |
https://revistas.unal.edu.co/index.php/ingeinv/article/view/53618 |
dc.relation.ispartof.spa.fl_str_mv |
Universidad Nacional de Colombia Revistas electrónicas UN Ingeniería e Investigación Ingeniería e Investigación |
dc.relation.references.spa.fl_str_mv |
Malagon, Gabriel Alexis and Bello Peña, Jeisson and Ordóñez Plata, Gabriel and Duarte Gualdrón, Cesar (2015) Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid. Ingeniería e Investigación, 35 (1Sup). pp. 89-97. ISSN 2248-8723 |
dc.rights.spa.fl_str_mv |
Derechos reservados - Universidad Nacional de Colombia |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial 4.0 Internacional Derechos reservados - Universidad Nacional de Colombia http://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Universidad Nacional de Colombia - Sede Bogotá - Facultad de Ingeniería |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/67658/1/53618-266809-3-PB.pdf https://repositorio.unal.edu.co/bitstream/unal/67658/2/53618-266809-3-PB.pdf.jpg |
bitstream.checksum.fl_str_mv |
9c819f1d9bade8a5eb22d50f5d939753 28f9cd77dc827511de7c6b11869b79b4 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814089405556588544 |
spelling |
Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Malagon, Gabriel Alexisb8a6964c-805a-4472-a79a-0358d2645eec300Bello Peña, Jeisson57fa20dd-5633-49b7-91ca-baeaad00eb4a300Ordóñez Plata, Gabrield18d5d11-5d61-4743-a552-495ce1f6315e300Duarte Gualdrón, Cesare8d5f5a8-0e1a-47c7-a556-3386de29cb5c3002019-07-03T04:47:20Z2019-07-03T04:47:20Z2015-06-01ISSN: 2248-8723https://repositorio.unal.edu.co/handle/unal/67658http://bdigital.unal.edu.co/68687/This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. Nevertheless, the derivation of this model is not straightforward to follow and its performance in 120V 60Hz systems is a matter of research work. In this paper, the analytical derivation of this CFL model is presented in detail and its performance is discussed when predicting the current of a CFL designed to operate in a 120V 60Hz electrical system. The derived model is separately implemented in both MATLAB® and ATP-EMTP® software using two different sets of parameters previously proposed for 230V 50Hz CFLs. These simulation results are compared against laboratory measurements using a programmable AC voltage source. The measurements and simulations considered seven CFLs 110/127V 60Hz with different power ratings supplied by a sinusoidal (not distorted) voltage source. The simulations under these conditions do not properly predict the current measurements and therefore the set of parameters and/or the model itself need to be adjusted for 120V 60Hz power grids.En este artículo se presenta un análisis y una discusión sobre el comportamiento de un modelo circuital para lámparas fluorescentes compactas (CFL) en una red eléctrica de 120V 60Hz. Este modelo es propuesto y validado en trabajos previos para lámparas fluorescentes compactas en sistemas de 230V 50Hz. Sin embargo, la derivación de este modelo no es fácil de seguir y su desempeño en una red de 120V 60Hz es materia de investigación. En este trabajo, la derivación analítica de este modelo de CFL se presenta en detalle y se discute su desempeño en la predicción de la corriente consumida por una CFL en un sistema eléctrico de 120V 60Hz. El modelo derivado es implementado tanto en MATLAB® como en ATP-EMTP®, utilizando dos diferentes conjuntos de parámetros previamente propuestos para lámparas fluorescentes compactas en 230V 50Hz. Estos resultados de simulación se comparan con mediciones de laboratorio obtenidas utilizando una fuente de tensión alterna programable. Las mediciones y simulaciones consideran siete lámparas fluorescentes compactas 110/127V 60Hz con diferentes potencias alimentadas por una fuente de tensión sinusoidal (no distorsionada). Las simulaciones bajo estas condiciones no predicen adecuadamente las mediciones realizadas y por lo tanto el conjunto de parámetros y/o el modelo necesitan ser ajustados para redes eléctricas de 120V 60Hz.application/pdfspaUniversidad Nacional de Colombia - Sede Bogotá - Facultad de Ingenieríahttps://revistas.unal.edu.co/index.php/ingeinv/article/view/53618Universidad Nacional de Colombia Revistas electrónicas UN Ingeniería e InvestigaciónIngeniería e InvestigaciónMalagon, Gabriel Alexis and Bello Peña, Jeisson and Ordóñez Plata, Gabriel and Duarte Gualdrón, Cesar (2015) Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid. Ingeniería e Investigación, 35 (1Sup). pp. 89-97. ISSN 2248-872362 Ingeniería y operaciones afines / EngineeringCFL circuit-based modelharmonics attenuationharmonics diversityharmonic load modelling.Modelo circuital CFLatenuación de armónicosdiversidad de armónicosmodelos de carga armónica.Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power gridArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL53618-266809-3-PB.pdfapplication/pdf1640354https://repositorio.unal.edu.co/bitstream/unal/67658/1/53618-266809-3-PB.pdf9c819f1d9bade8a5eb22d50f5d939753MD51THUMBNAIL53618-266809-3-PB.pdf.jpg53618-266809-3-PB.pdf.jpgGenerated Thumbnailimage/jpeg8934https://repositorio.unal.edu.co/bitstream/unal/67658/2/53618-266809-3-PB.pdf.jpg28f9cd77dc827511de7c6b11869b79b4MD52unal/67658oai:repositorio.unal.edu.co:unal/676582024-05-22 23:34:10.097Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co |