Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid

This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. Nevertheless, the derivation of this model...

Full description

Autores:
Malagon, Gabriel Alexis
Bello Peña, Jeisson
Ordóñez Plata, Gabriel
Duarte Gualdrón, Cesar
Tipo de recurso:
Article of journal
Fecha de publicación:
2015
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/67658
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/67658
http://bdigital.unal.edu.co/68687/
Palabra clave:
62 Ingeniería y operaciones afines / Engineering
CFL circuit-based model
harmonics attenuation
harmonics diversity
harmonic load modelling.
Modelo circuital CFL
atenuación de armónicos
diversidad de armónicos
modelos de carga armónica.
Rights
openAccess
License
Atribución-NoComercial 4.0 Internacional
id UNACIONAL2_2b495fd5613877f4acf68ea12b7959e7
oai_identifier_str oai:repositorio.unal.edu.co:unal/67658
network_acronym_str UNACIONAL2
network_name_str Universidad Nacional de Colombia
repository_id_str
dc.title.spa.fl_str_mv Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
title Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
spellingShingle Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
62 Ingeniería y operaciones afines / Engineering
CFL circuit-based model
harmonics attenuation
harmonics diversity
harmonic load modelling.
Modelo circuital CFL
atenuación de armónicos
diversidad de armónicos
modelos de carga armónica.
title_short Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
title_full Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
title_fullStr Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
title_full_unstemmed Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
title_sort Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid
dc.creator.fl_str_mv Malagon, Gabriel Alexis
Bello Peña, Jeisson
Ordóñez Plata, Gabriel
Duarte Gualdrón, Cesar
dc.contributor.author.spa.fl_str_mv Malagon, Gabriel Alexis
Bello Peña, Jeisson
Ordóñez Plata, Gabriel
Duarte Gualdrón, Cesar
dc.subject.ddc.spa.fl_str_mv 62 Ingeniería y operaciones afines / Engineering
topic 62 Ingeniería y operaciones afines / Engineering
CFL circuit-based model
harmonics attenuation
harmonics diversity
harmonic load modelling.
Modelo circuital CFL
atenuación de armónicos
diversidad de armónicos
modelos de carga armónica.
dc.subject.proposal.spa.fl_str_mv CFL circuit-based model
harmonics attenuation
harmonics diversity
harmonic load modelling.
Modelo circuital CFL
atenuación de armónicos
diversidad de armónicos
modelos de carga armónica.
description This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. Nevertheless, the derivation of this model is not straightforward to follow and its performance in 120V 60Hz systems is a matter of research work. In this paper, the analytical derivation of this CFL model is presented in detail and its performance is discussed when predicting the current of a CFL designed to operate in a 120V 60Hz electrical system. The derived model is separately implemented in both MATLAB® and ATP-EMTP® software using two different sets of parameters previously proposed for 230V 50Hz CFLs. These simulation results are compared against laboratory measurements using a programmable AC voltage source. The measurements and simulations considered seven CFLs 110/127V 60Hz with different power ratings supplied by a sinusoidal (not distorted) voltage source. The simulations under these conditions do not properly predict the current measurements and therefore the set of parameters and/or the model itself need to be adjusted for 120V 60Hz power grids.
publishDate 2015
dc.date.issued.spa.fl_str_mv 2015-06-01
dc.date.accessioned.spa.fl_str_mv 2019-07-03T04:47:20Z
dc.date.available.spa.fl_str_mv 2019-07-03T04:47:20Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.issn.spa.fl_str_mv ISSN: 2248-8723
dc.identifier.uri.none.fl_str_mv https://repositorio.unal.edu.co/handle/unal/67658
dc.identifier.eprints.spa.fl_str_mv http://bdigital.unal.edu.co/68687/
identifier_str_mv ISSN: 2248-8723
url https://repositorio.unal.edu.co/handle/unal/67658
http://bdigital.unal.edu.co/68687/
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv https://revistas.unal.edu.co/index.php/ingeinv/article/view/53618
dc.relation.ispartof.spa.fl_str_mv Universidad Nacional de Colombia Revistas electrónicas UN Ingeniería e Investigación
Ingeniería e Investigación
dc.relation.references.spa.fl_str_mv Malagon, Gabriel Alexis and Bello Peña, Jeisson and Ordóñez Plata, Gabriel and Duarte Gualdrón, Cesar (2015) Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid. Ingeniería e Investigación, 35 (1Sup). pp. 89-97. ISSN 2248-8723
dc.rights.spa.fl_str_mv Derechos reservados - Universidad Nacional de Colombia
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.license.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional
dc.rights.uri.spa.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv Atribución-NoComercial 4.0 Internacional
Derechos reservados - Universidad Nacional de Colombia
http://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Nacional de Colombia - Sede Bogotá - Facultad de Ingeniería
institution Universidad Nacional de Colombia
bitstream.url.fl_str_mv https://repositorio.unal.edu.co/bitstream/unal/67658/1/53618-266809-3-PB.pdf
https://repositorio.unal.edu.co/bitstream/unal/67658/2/53618-266809-3-PB.pdf.jpg
bitstream.checksum.fl_str_mv 9c819f1d9bade8a5eb22d50f5d939753
28f9cd77dc827511de7c6b11869b79b4
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad Nacional de Colombia
repository.mail.fl_str_mv repositorio_nal@unal.edu.co
_version_ 1814089405556588544
spelling Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Malagon, Gabriel Alexisb8a6964c-805a-4472-a79a-0358d2645eec300Bello Peña, Jeisson57fa20dd-5633-49b7-91ca-baeaad00eb4a300Ordóñez Plata, Gabrield18d5d11-5d61-4743-a552-495ce1f6315e300Duarte Gualdrón, Cesare8d5f5a8-0e1a-47c7-a556-3386de29cb5c3002019-07-03T04:47:20Z2019-07-03T04:47:20Z2015-06-01ISSN: 2248-8723https://repositorio.unal.edu.co/handle/unal/67658http://bdigital.unal.edu.co/68687/This article presents an analysis and discussion on the performance of a circuit-based model for Compact Fluorescent Lamps (CFL) in a 120V 60Hz power grid. This model is proposed and validated in previous scientific literature for CFLs in 230V 50Hz systems. Nevertheless, the derivation of this model is not straightforward to follow and its performance in 120V 60Hz systems is a matter of research work. In this paper, the analytical derivation of this CFL model is presented in detail and its performance is discussed when predicting the current of a CFL designed to operate in a 120V 60Hz electrical system. The derived model is separately implemented in both MATLAB® and ATP-EMTP® software using two different sets of parameters previously proposed for 230V 50Hz CFLs. These simulation results are compared against laboratory measurements using a programmable AC voltage source. The measurements and simulations considered seven CFLs 110/127V 60Hz with different power ratings supplied by a sinusoidal (not distorted) voltage source. The simulations under these conditions do not properly predict the current measurements and therefore the set of parameters and/or the model itself need to be adjusted for 120V 60Hz power grids.En este artículo se presenta un análisis y una discusión sobre el  comportamiento de un modelo circuital para lámparas fluorescentes compactas (CFL) en una red eléctrica de 120V 60Hz. Este modelo es propuesto y validado en trabajos previos para lámparas fluorescentes compactas en sistemas de 230V 50Hz. Sin embargo, la derivación de este modelo no es fácil de seguir y su desempeño en una red de 120V 60Hz es materia de investigación. En este trabajo, la derivación analítica de este modelo de CFL se presenta en detalle y se discute su desempeño en la predicción de la corriente consumida por una CFL en un sistema eléctrico de 120V 60Hz. El modelo derivado es implementado tanto en MATLAB® como en ATP-EMTP®, utilizando dos diferentes conjuntos de parámetros previamente propuestos para lámparas fluorescentes compactas en 230V 50Hz. Estos resultados de simulación se comparan con mediciones de laboratorio obtenidas utilizando una fuente de tensión alterna programable. Las mediciones y simulaciones consideran siete lámparas fluorescentes compactas 110/127V 60Hz con diferentes  potencias alimentadas por una fuente de tensión sinusoidal (no distorsionada). Las simulaciones bajo estas condiciones no predicen adecuadamente las mediciones realizadas y por lo tanto el conjunto de parámetros y/o el modelo necesitan ser ajustados para redes eléctricas de 120V 60Hz.application/pdfspaUniversidad Nacional de Colombia - Sede Bogotá - Facultad de Ingenieríahttps://revistas.unal.edu.co/index.php/ingeinv/article/view/53618Universidad Nacional de Colombia Revistas electrónicas UN Ingeniería e InvestigaciónIngeniería e InvestigaciónMalagon, Gabriel Alexis and Bello Peña, Jeisson and Ordóñez Plata, Gabriel and Duarte Gualdrón, Cesar (2015) Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power grid. Ingeniería e Investigación, 35 (1Sup). pp. 89-97. ISSN 2248-872362 Ingeniería y operaciones afines / EngineeringCFL circuit-based modelharmonics attenuationharmonics diversityharmonic load modelling.Modelo circuital CFLatenuación de armónicosdiversidad de armónicosmodelos de carga armónica.Analytical and experimental discussion of a circuit-based model for compact fluorescent lamps in a 60Hz power gridArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL53618-266809-3-PB.pdfapplication/pdf1640354https://repositorio.unal.edu.co/bitstream/unal/67658/1/53618-266809-3-PB.pdf9c819f1d9bade8a5eb22d50f5d939753MD51THUMBNAIL53618-266809-3-PB.pdf.jpg53618-266809-3-PB.pdf.jpgGenerated Thumbnailimage/jpeg8934https://repositorio.unal.edu.co/bitstream/unal/67658/2/53618-266809-3-PB.pdf.jpg28f9cd77dc827511de7c6b11869b79b4MD52unal/67658oai:repositorio.unal.edu.co:unal/676582024-05-22 23:34:10.097Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co