Analytical method validation for determination of total mercury in human blood by zeeman mercury spectrometer ra-915+ with the pyrolysis module pyro-915+
This article describes the methodology of the validation about the identification of total mercury in blood samples by Zeeman atomic absorption spectrophotometry RA-915+ with the module of Pyrolysis PYRO-915+, suitable for the direct determination of total mercury concentrations in various matrices,...
- Autores:
-
Ramírez, Carolina
Olarte, Ermel
Tellez, Eliana
Palma, Marien
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2013
- Institución:
- Universidad Nacional de Colombia
- Repositorio:
- Universidad Nacional de Colombia
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.unal.edu.co:unal/49811
- Acceso en línea:
- https://repositorio.unal.edu.co/handle/unal/49811
http://bdigital.unal.edu.co/43301/
- Palabra clave:
- mercurio
validación de métodos
espectrofotometría de absorción atómica
mercury
analytical methods validation
atomic absorption spectrophotometry
- Rights
- openAccess
- License
- Atribución-NoComercial 4.0 Internacional
id |
UNACIONAL2_1a231fb44864edc62ca0bb1856971d30 |
---|---|
oai_identifier_str |
oai:repositorio.unal.edu.co:unal/49811 |
network_acronym_str |
UNACIONAL2 |
network_name_str |
Universidad Nacional de Colombia |
repository_id_str |
|
dc.title.spa.fl_str_mv |
Analytical method validation for determination of total mercury in human blood by zeeman mercury spectrometer ra-915+ with the pyrolysis module pyro-915+ |
title |
Analytical method validation for determination of total mercury in human blood by zeeman mercury spectrometer ra-915+ with the pyrolysis module pyro-915+ |
spellingShingle |
Analytical method validation for determination of total mercury in human blood by zeeman mercury spectrometer ra-915+ with the pyrolysis module pyro-915+ mercurio validación de métodos espectrofotometría de absorción atómica mercury analytical methods validation atomic absorption spectrophotometry |
title_short |
Analytical method validation for determination of total mercury in human blood by zeeman mercury spectrometer ra-915+ with the pyrolysis module pyro-915+ |
title_full |
Analytical method validation for determination of total mercury in human blood by zeeman mercury spectrometer ra-915+ with the pyrolysis module pyro-915+ |
title_fullStr |
Analytical method validation for determination of total mercury in human blood by zeeman mercury spectrometer ra-915+ with the pyrolysis module pyro-915+ |
title_full_unstemmed |
Analytical method validation for determination of total mercury in human blood by zeeman mercury spectrometer ra-915+ with the pyrolysis module pyro-915+ |
title_sort |
Analytical method validation for determination of total mercury in human blood by zeeman mercury spectrometer ra-915+ with the pyrolysis module pyro-915+ |
dc.creator.fl_str_mv |
Ramírez, Carolina Olarte, Ermel Tellez, Eliana Palma, Marien |
dc.contributor.author.spa.fl_str_mv |
Ramírez, Carolina Olarte, Ermel Tellez, Eliana Palma, Marien |
dc.subject.proposal.spa.fl_str_mv |
mercurio validación de métodos espectrofotometría de absorción atómica mercury analytical methods validation atomic absorption spectrophotometry |
topic |
mercurio validación de métodos espectrofotometría de absorción atómica mercury analytical methods validation atomic absorption spectrophotometry |
description |
This article describes the methodology of the validation about the identification of total mercury in blood samples by Zeeman atomic absorption spectrophotometry RA-915+ with the module of Pyrolysis PYRO-915+, suitable for the direct determination of total mercury concentrations in various matrices, that unlike other atomization techniques (graphite furnace, cold vapor or hydride generator) does not require a sample pre-treatment. With the application of this validation, is provided the reliability in the results. Most of the validation parameters were subjected to analysis of variance ANOVA with a confidence level of 95%. It was obtained a detection limit of 2.16 µg/L, a quantitation limit of 5.54µg/L and linearity in the range of 5.54 µg/L to , in addition, the precision and accuracy was evaluated, obtaining favorable results in the analysis. The calculation of the expanded uncertainty for this method was 0.610 µg/L. |
publishDate |
2013 |
dc.date.issued.spa.fl_str_mv |
2013 |
dc.date.accessioned.spa.fl_str_mv |
2019-06-29T09:20:33Z |
dc.date.available.spa.fl_str_mv |
2019-06-29T09:20:33Z |
dc.type.spa.fl_str_mv |
Artículo de revista |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.coarversion.spa.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
dc.type.content.spa.fl_str_mv |
Text |
dc.type.redcol.spa.fl_str_mv |
http://purl.org/redcol/resource_type/ART |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.unal.edu.co/handle/unal/49811 |
dc.identifier.eprints.spa.fl_str_mv |
http://bdigital.unal.edu.co/43301/ |
url |
https://repositorio.unal.edu.co/handle/unal/49811 http://bdigital.unal.edu.co/43301/ |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.spa.fl_str_mv |
http://revistas.unal.edu.co/index.php/rcolquim/article/view/45909 |
dc.relation.ispartof.spa.fl_str_mv |
Universidad Nacional de Colombia Revistas electrónicas UN Revista Colombiana de Química Revista Colombiana de Química |
dc.relation.ispartofseries.none.fl_str_mv |
Revista Colombiana de Química; Vol. 42, núm. 3 (2013): Versión preliminar; 326-343 2357-3791 0120-2804 |
dc.relation.references.spa.fl_str_mv |
Ramírez, Carolina and Olarte, Ermel and Tellez, Eliana and Palma, Marien (2013) Analytical method validation for determination of total mercury in human blood by zeeman mercury spectrometer ra-915+ with the pyrolysis module pyro-915+. Revista Colombiana de Química; Vol. 42, núm. 3 (2013): Versión preliminar; 326-343 2357-3791 0120-2804 . |
dc.rights.spa.fl_str_mv |
Derechos reservados - Universidad Nacional de Colombia |
dc.rights.coar.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
dc.rights.license.spa.fl_str_mv |
Atribución-NoComercial 4.0 Internacional |
dc.rights.uri.spa.fl_str_mv |
http://creativecommons.org/licenses/by-nc/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Atribución-NoComercial 4.0 Internacional Derechos reservados - Universidad Nacional de Colombia http://creativecommons.org/licenses/by-nc/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.mimetype.spa.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Universidad Nacional de Colombia |
institution |
Universidad Nacional de Colombia |
bitstream.url.fl_str_mv |
https://repositorio.unal.edu.co/bitstream/unal/49811/1/45909-222616-1-SM.pdf https://repositorio.unal.edu.co/bitstream/unal/49811/2/45909-222616-1-SM.pdf.jpg |
bitstream.checksum.fl_str_mv |
50c13d8fba975a071d533817bebe9bbc d9e5d7e21eca4f07ec7221bf393f3d23 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional Universidad Nacional de Colombia |
repository.mail.fl_str_mv |
repositorio_nal@unal.edu.co |
_version_ |
1814089630612455424 |
spelling |
Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Ramírez, Carolina0186cbd0-620b-415b-a672-fa0918519f6c300Olarte, Ermel2197594f-cb01-47cf-a4fa-34fe4302a16a300Tellez, Elianadbb15bab-9c64-4634-9c66-f60c71040a48300Palma, Marien3c3e9d67-f4ff-47de-99a5-e6b5796512d13002019-06-29T09:20:33Z2019-06-29T09:20:33Z2013https://repositorio.unal.edu.co/handle/unal/49811http://bdigital.unal.edu.co/43301/This article describes the methodology of the validation about the identification of total mercury in blood samples by Zeeman atomic absorption spectrophotometry RA-915+ with the module of Pyrolysis PYRO-915+, suitable for the direct determination of total mercury concentrations in various matrices, that unlike other atomization techniques (graphite furnace, cold vapor or hydride generator) does not require a sample pre-treatment. With the application of this validation, is provided the reliability in the results. Most of the validation parameters were subjected to analysis of variance ANOVA with a confidence level of 95%. It was obtained a detection limit of 2.16 µg/L, a quantitation limit of 5.54µg/L and linearity in the range of 5.54 µg/L to , in addition, the precision and accuracy was evaluated, obtaining favorable results in the analysis. The calculation of the expanded uncertainty for this method was 0.610 µg/L.Este artículo describe la metodología de validación para la técnica de identificación de mercurio total en muestras de sangre por espectrofotometría de absorción atómica Zeeman RA-915+ con el módulo de Pirólisis PYRO-915+, adecuada para la determinación directa de las concentraciones de mercurio total en varias matrices, que a diferencia de otras técnicas de atomización (horno de grafito, vapor frio, o generador de hidruros) no necesita un pre-tratamiento de la muestra. Con la aplicación de ésta validación en la realización de los análisis se brinda la confiabilidad necesaria en la obtención y emisión de los resultados. La mayoría de parámetros de la validación, se sometieron a análisis de varianza tipo ANOVA con un nivel de confianza del 95 %. Se obtuvo un límite de detección de 2.16 µg/L, un límite de cuantificación de 5.54 µg/L y una linealidad en el rango de 5.54 µg/L a 100 µg/L, adicionalmente, se evaluó exactitud y precisión, obteniendo resultados favorables para el análisis. El cálculo de la incertidumbre expandida para este método fue 0.610 µg/L.application/pdfspaUniversidad Nacional de Colombiahttp://revistas.unal.edu.co/index.php/rcolquim/article/view/45909Universidad Nacional de Colombia Revistas electrónicas UN Revista Colombiana de QuímicaRevista Colombiana de QuímicaRevista Colombiana de Química; Vol. 42, núm. 3 (2013): Versión preliminar; 326-343 2357-3791 0120-2804Ramírez, Carolina and Olarte, Ermel and Tellez, Eliana and Palma, Marien (2013) Analytical method validation for determination of total mercury in human blood by zeeman mercury spectrometer ra-915+ with the pyrolysis module pyro-915+. Revista Colombiana de Química; Vol. 42, núm. 3 (2013): Versión preliminar; 326-343 2357-3791 0120-2804 .Analytical method validation for determination of total mercury in human blood by zeeman mercury spectrometer ra-915+ with the pyrolysis module pyro-915+Artículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTmercuriovalidación de métodosespectrofotometría de absorción atómicamercuryanalytical methods validationatomic absorption spectrophotometryORIGINAL45909-222616-1-SM.pdfapplication/pdf1022300https://repositorio.unal.edu.co/bitstream/unal/49811/1/45909-222616-1-SM.pdf50c13d8fba975a071d533817bebe9bbcMD51THUMBNAIL45909-222616-1-SM.pdf.jpg45909-222616-1-SM.pdf.jpgGenerated Thumbnailimage/jpeg6226https://repositorio.unal.edu.co/bitstream/unal/49811/2/45909-222616-1-SM.pdf.jpgd9e5d7e21eca4f07ec7221bf393f3d23MD52unal/49811oai:repositorio.unal.edu.co:unal/498112023-12-11 23:07:27.723Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co |