Determining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications

In this study, experimental investigations were carried out on polypropylene fiber (PF), steel mesh (SM) and PF+SMreinforced shotcrete (RS) panels to evaluate performance characteristics of energy absorption and load capacity. Inaddition to this, material cost evaluation of shotcrete mixtures for un...

Full description

Autores:
Kahraman, Bayram
Tipo de recurso:
Article of journal
Fecha de publicación:
2015
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/63652
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/63652
http://bdigital.unal.edu.co/64098/
Palabra clave:
55 Ciencias de la tierra / Earth sciences and geology
Shotcrete
Polypropylene Fiber
Energy Absorption
Panel test
Rights
openAccess
License
Atribución-NoComercial 4.0 Internacional
id UNACIONAL2_0d8d656199b06540d9f62d18dc01e92f
oai_identifier_str oai:repositorio.unal.edu.co:unal/63652
network_acronym_str UNACIONAL2
network_name_str Universidad Nacional de Colombia
repository_id_str
spelling Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Kahraman, Bayram3e6cb7c5-3bd0-460d-aa2c-f88ecfd4f3ce3002019-07-02T21:59:47Z2019-07-02T21:59:47Z2015-01-01ISSN: 2339-3459https://repositorio.unal.edu.co/handle/unal/63652http://bdigital.unal.edu.co/64098/In this study, experimental investigations were carried out on polypropylene fiber (PF), steel mesh (SM) and PF+SMreinforced shotcrete (RS) panels to evaluate performance characteristics of energy absorption and load capacity. Inaddition to this, material cost evaluation of shotcrete mixtures for unit energy absorption and load capacity has been given.The panel tests, along with the European specification for sprayed concrete (EFNARC), were done on 18 prismaticspecimens having the same mix designs and were cured for 28 days but reinforced at varying fiber dosages. Testresults indicate that in terms of unit cost performance for PF, the best dosages were 2 kg/m³ and 5 kg/m³ respectively.When compared with SM, it was determined that PF is more expensive within the range of 37 - 53%. ResumenEn este estudio se realizaron investigaciones experimentales en fibras de polipropileno, en mallas de acero y en paneles de hormigón proyectado reforzados con fibra de polipropileno y con mallas de acero para evaluar las características de desempeño en absorción de energía y en capacidad de carga. Adicionalmente, se provee una evaluación del costo de materiales en mezlas de hormigón proyectado por unidad de absorción de energía y por capacidad de carga. Los exámenes en paneles, con las especificaciones europeas para hormigón proyectado (EFNARC, inglés), se realizaron en 18 muestras prismáticas con los mismos diseños de mezcla y se curaron por 28 días con refuerzos de diferentes dosis de fibras. Los resultados de la evaluación indican que, en términos de desempeño por unidad de costo para fibras de polipropileno, las mejores dosis fueron 2 kg/m3 y 5 kg/m3, respectivamente. Cuando se comparó con las mallas de acero, se determinó que las fibras de polipropileno son entre el 37 % y el 53 % más caras.application/pdfspaUniversidad Nacional de Colombia - Sede Bogotá - Facultad de Ciencias - Departamento de Geocienciahttps://revistas.unal.edu.co/index.php/esrj/article/view/40995Universidad Nacional de Colombia Revistas electrónicas UN Earth Sciences Research JournalEarth Sciences Research JournalKahraman, Bayram (2015) Determining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications. Earth Sciences Research Journal, 19 (1). pp. 81-84. ISSN 2339-345955 Ciencias de la tierra / Earth sciences and geologyShotcretePolypropylene FiberEnergy AbsorptionPanel testDetermining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering ApplicationsArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL40995-251279-2-PB.pdfapplication/pdf1241219https://repositorio.unal.edu.co/bitstream/unal/63652/1/40995-251279-2-PB.pdf04294fcc2de9165af0504f243ebc1c8bMD51THUMBNAIL40995-251279-2-PB.pdf.jpg40995-251279-2-PB.pdf.jpgGenerated Thumbnailimage/jpeg5896https://repositorio.unal.edu.co/bitstream/unal/63652/2/40995-251279-2-PB.pdf.jpge911f1aaed4280fd561fff607130974eMD52unal/63652oai:repositorio.unal.edu.co:unal/636522024-04-30 23:10:34.21Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co
dc.title.spa.fl_str_mv Determining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications
title Determining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications
spellingShingle Determining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications
55 Ciencias de la tierra / Earth sciences and geology
Shotcrete
Polypropylene Fiber
Energy Absorption
Panel test
title_short Determining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications
title_full Determining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications
title_fullStr Determining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications
title_full_unstemmed Determining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications
title_sort Determining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications
dc.creator.fl_str_mv Kahraman, Bayram
dc.contributor.author.spa.fl_str_mv Kahraman, Bayram
dc.subject.ddc.spa.fl_str_mv 55 Ciencias de la tierra / Earth sciences and geology
topic 55 Ciencias de la tierra / Earth sciences and geology
Shotcrete
Polypropylene Fiber
Energy Absorption
Panel test
dc.subject.proposal.spa.fl_str_mv Shotcrete
Polypropylene Fiber
Energy Absorption
Panel test
description In this study, experimental investigations were carried out on polypropylene fiber (PF), steel mesh (SM) and PF+SMreinforced shotcrete (RS) panels to evaluate performance characteristics of energy absorption and load capacity. Inaddition to this, material cost evaluation of shotcrete mixtures for unit energy absorption and load capacity has been given.The panel tests, along with the European specification for sprayed concrete (EFNARC), were done on 18 prismaticspecimens having the same mix designs and were cured for 28 days but reinforced at varying fiber dosages. Testresults indicate that in terms of unit cost performance for PF, the best dosages were 2 kg/m³ and 5 kg/m³ respectively.When compared with SM, it was determined that PF is more expensive within the range of 37 - 53%. ResumenEn este estudio se realizaron investigaciones experimentales en fibras de polipropileno, en mallas de acero y en paneles de hormigón proyectado reforzados con fibra de polipropileno y con mallas de acero para evaluar las características de desempeño en absorción de energía y en capacidad de carga. Adicionalmente, se provee una evaluación del costo de materiales en mezlas de hormigón proyectado por unidad de absorción de energía y por capacidad de carga. Los exámenes en paneles, con las especificaciones europeas para hormigón proyectado (EFNARC, inglés), se realizaron en 18 muestras prismáticas con los mismos diseños de mezcla y se curaron por 28 días con refuerzos de diferentes dosis de fibras. Los resultados de la evaluación indican que, en términos de desempeño por unidad de costo para fibras de polipropileno, las mejores dosis fueron 2 kg/m3 y 5 kg/m3, respectivamente. Cuando se comparó con las mallas de acero, se determinó que las fibras de polipropileno son entre el 37 % y el 53 % más caras.
publishDate 2015
dc.date.issued.spa.fl_str_mv 2015-01-01
dc.date.accessioned.spa.fl_str_mv 2019-07-02T21:59:47Z
dc.date.available.spa.fl_str_mv 2019-07-02T21:59:47Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.issn.spa.fl_str_mv ISSN: 2339-3459
dc.identifier.uri.none.fl_str_mv https://repositorio.unal.edu.co/handle/unal/63652
dc.identifier.eprints.spa.fl_str_mv http://bdigital.unal.edu.co/64098/
identifier_str_mv ISSN: 2339-3459
url https://repositorio.unal.edu.co/handle/unal/63652
http://bdigital.unal.edu.co/64098/
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv https://revistas.unal.edu.co/index.php/esrj/article/view/40995
dc.relation.ispartof.spa.fl_str_mv Universidad Nacional de Colombia Revistas electrónicas UN Earth Sciences Research Journal
Earth Sciences Research Journal
dc.relation.references.spa.fl_str_mv Kahraman, Bayram (2015) Determining Optimal Polypropylene Fiber Dosages In Sprayed Concrete For Mining And Civil Engineering Applications. Earth Sciences Research Journal, 19 (1). pp. 81-84. ISSN 2339-3459
dc.rights.spa.fl_str_mv Derechos reservados - Universidad Nacional de Colombia
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.license.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional
dc.rights.uri.spa.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv Atribución-NoComercial 4.0 Internacional
Derechos reservados - Universidad Nacional de Colombia
http://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Nacional de Colombia - Sede Bogotá - Facultad de Ciencias - Departamento de Geociencia
institution Universidad Nacional de Colombia
bitstream.url.fl_str_mv https://repositorio.unal.edu.co/bitstream/unal/63652/1/40995-251279-2-PB.pdf
https://repositorio.unal.edu.co/bitstream/unal/63652/2/40995-251279-2-PB.pdf.jpg
bitstream.checksum.fl_str_mv 04294fcc2de9165af0504f243ebc1c8b
e911f1aaed4280fd561fff607130974e
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad Nacional de Colombia
repository.mail.fl_str_mv repositorio_nal@unal.edu.co
_version_ 1814089239746314240