Methodology for Relative Location of Voltage Sags Source using Voltage Measurements Only

This paper presents a methodology for the relative location of voltage sags source based on voltage measurements only. Network faults are the most frequent disturbances in the electrical systems and in turn are the causes that generate most voltage sags. Thus, the proposed algorithm considers only v...

Full description

Autores:
Blanco Solano, Jairo
Petit Suárez, Johann F.
Ordóñez Plata, Gabriel Ordóñez Plata
Tipo de recurso:
Article of journal
Fecha de publicación:
2015
Institución:
Universidad Nacional de Colombia
Repositorio:
Universidad Nacional de Colombia
Idioma:
spa
OAI Identifier:
oai:repositorio.unal.edu.co:unal/60687
Acceso en línea:
https://repositorio.unal.edu.co/handle/unal/60687
http://bdigital.unal.edu.co/59019/
Palabra clave:
62 Ingeniería y operaciones afines / Engineering
Power quality monitoring
relative location
voltage sags
positive sequence voltage
network faults
Rights
openAccess
License
Atribución-NoComercial 4.0 Internacional
id UNACIONAL2_03c92c23abd749d06eab4a0b3b8b833c
oai_identifier_str oai:repositorio.unal.edu.co:unal/60687
network_acronym_str UNACIONAL2
network_name_str Universidad Nacional de Colombia
repository_id_str
spelling Atribución-NoComercial 4.0 InternacionalDerechos reservados - Universidad Nacional de Colombiahttp://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Blanco Solano, Jairo6c73f95e-0200-4255-8747-88bde204c87a300Petit Suárez, Johann F.430081b9-2c00-491b-a8b6-74339cdd210f300Ordóñez Plata, Gabriel Ordóñez Plata9a1b4f71-8a0c-4602-9557-3d91307634b13002019-07-02T18:53:10Z2019-07-02T18:53:10Z2015-07-01ISSN: 2346-2183https://repositorio.unal.edu.co/handle/unal/60687http://bdigital.unal.edu.co/59019/This paper presents a methodology for the relative location of voltage sags source based on voltage measurements only. Network faults are the most frequent disturbances in the electrical systems and in turn are the causes that generate most voltage sags. Thus, the proposed algorithm considers only voltage sags by network faults and a minimum of three voltage meters are required. Power quality can be evaluated automatically using the characterising and extracting information from voltage records. The positive sequence voltages are the descriptors used to determine the relative location of the voltage sags causes and the methodology is applied to a simulation where its effectiveness is verified. Matlab was used for validating this methodology, receiving voltage records of simulated voltage sags in ATP-EMTP.application/pdfspaUniversidad Nacional de Colombia (Sede Medellín). Facultad de Minas.https://revistas.unal.edu.co/index.php/dyna/article/view/48581Universidad Nacional de Colombia Revistas electrónicas UN DynaDynaBlanco Solano, Jairo and Petit Suárez, Johann F. and Ordóñez Plata, Gabriel Ordóñez Plata (2015) Methodology for Relative Location of Voltage Sags Source using Voltage Measurements Only. DYNA, 82 (192). pp. 94-100. ISSN 2346-218362 Ingeniería y operaciones afines / EngineeringPower quality monitoringrelative locationvoltage sagspositive sequence voltagenetwork faultsMethodology for Relative Location of Voltage Sags Source using Voltage Measurements OnlyArtículo de revistainfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Texthttp://purl.org/redcol/resource_type/ARTORIGINAL48581-257552-1-PB.pdfapplication/pdf895367https://repositorio.unal.edu.co/bitstream/unal/60687/1/48581-257552-1-PB.pdf48919054be19322b948b06e49c94b91fMD51THUMBNAIL48581-257552-1-PB.pdf.jpg48581-257552-1-PB.pdf.jpgGenerated Thumbnailimage/jpeg9319https://repositorio.unal.edu.co/bitstream/unal/60687/2/48581-257552-1-PB.pdf.jpg73d2520d54ddb32d8a45b6e1304771e7MD52unal/60687oai:repositorio.unal.edu.co:unal/606872023-04-08 23:04:52.121Repositorio Institucional Universidad Nacional de Colombiarepositorio_nal@unal.edu.co
dc.title.spa.fl_str_mv Methodology for Relative Location of Voltage Sags Source using Voltage Measurements Only
title Methodology for Relative Location of Voltage Sags Source using Voltage Measurements Only
spellingShingle Methodology for Relative Location of Voltage Sags Source using Voltage Measurements Only
62 Ingeniería y operaciones afines / Engineering
Power quality monitoring
relative location
voltage sags
positive sequence voltage
network faults
title_short Methodology for Relative Location of Voltage Sags Source using Voltage Measurements Only
title_full Methodology for Relative Location of Voltage Sags Source using Voltage Measurements Only
title_fullStr Methodology for Relative Location of Voltage Sags Source using Voltage Measurements Only
title_full_unstemmed Methodology for Relative Location of Voltage Sags Source using Voltage Measurements Only
title_sort Methodology for Relative Location of Voltage Sags Source using Voltage Measurements Only
dc.creator.fl_str_mv Blanco Solano, Jairo
Petit Suárez, Johann F.
Ordóñez Plata, Gabriel Ordóñez Plata
dc.contributor.author.spa.fl_str_mv Blanco Solano, Jairo
Petit Suárez, Johann F.
Ordóñez Plata, Gabriel Ordóñez Plata
dc.subject.ddc.spa.fl_str_mv 62 Ingeniería y operaciones afines / Engineering
topic 62 Ingeniería y operaciones afines / Engineering
Power quality monitoring
relative location
voltage sags
positive sequence voltage
network faults
dc.subject.proposal.spa.fl_str_mv Power quality monitoring
relative location
voltage sags
positive sequence voltage
network faults
description This paper presents a methodology for the relative location of voltage sags source based on voltage measurements only. Network faults are the most frequent disturbances in the electrical systems and in turn are the causes that generate most voltage sags. Thus, the proposed algorithm considers only voltage sags by network faults and a minimum of three voltage meters are required. Power quality can be evaluated automatically using the characterising and extracting information from voltage records. The positive sequence voltages are the descriptors used to determine the relative location of the voltage sags causes and the methodology is applied to a simulation where its effectiveness is verified. Matlab was used for validating this methodology, receiving voltage records of simulated voltage sags in ATP-EMTP.
publishDate 2015
dc.date.issued.spa.fl_str_mv 2015-07-01
dc.date.accessioned.spa.fl_str_mv 2019-07-02T18:53:10Z
dc.date.available.spa.fl_str_mv 2019-07-02T18:53:10Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.driver.spa.fl_str_mv info:eu-repo/semantics/article
dc.type.version.spa.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.coar.spa.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.spa.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.content.spa.fl_str_mv Text
dc.type.redcol.spa.fl_str_mv http://purl.org/redcol/resource_type/ART
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.issn.spa.fl_str_mv ISSN: 2346-2183
dc.identifier.uri.none.fl_str_mv https://repositorio.unal.edu.co/handle/unal/60687
dc.identifier.eprints.spa.fl_str_mv http://bdigital.unal.edu.co/59019/
identifier_str_mv ISSN: 2346-2183
url https://repositorio.unal.edu.co/handle/unal/60687
http://bdigital.unal.edu.co/59019/
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv https://revistas.unal.edu.co/index.php/dyna/article/view/48581
dc.relation.ispartof.spa.fl_str_mv Universidad Nacional de Colombia Revistas electrónicas UN Dyna
Dyna
dc.relation.references.spa.fl_str_mv Blanco Solano, Jairo and Petit Suárez, Johann F. and Ordóñez Plata, Gabriel Ordóñez Plata (2015) Methodology for Relative Location of Voltage Sags Source using Voltage Measurements Only. DYNA, 82 (192). pp. 94-100. ISSN 2346-2183
dc.rights.spa.fl_str_mv Derechos reservados - Universidad Nacional de Colombia
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
dc.rights.license.spa.fl_str_mv Atribución-NoComercial 4.0 Internacional
dc.rights.uri.spa.fl_str_mv http://creativecommons.org/licenses/by-nc/4.0/
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv Atribución-NoComercial 4.0 Internacional
Derechos reservados - Universidad Nacional de Colombia
http://creativecommons.org/licenses/by-nc/4.0/
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Nacional de Colombia (Sede Medellín). Facultad de Minas.
institution Universidad Nacional de Colombia
bitstream.url.fl_str_mv https://repositorio.unal.edu.co/bitstream/unal/60687/1/48581-257552-1-PB.pdf
https://repositorio.unal.edu.co/bitstream/unal/60687/2/48581-257552-1-PB.pdf.jpg
bitstream.checksum.fl_str_mv 48919054be19322b948b06e49c94b91f
73d2520d54ddb32d8a45b6e1304771e7
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad Nacional de Colombia
repository.mail.fl_str_mv repositorio_nal@unal.edu.co
_version_ 1814089209878675456