Evaluación ex vivo de la retención de estructuras en Zirconia-ytria de procera con diferentes cementos
ABSTRACT: Since the specialized literature does not report reliable protocols for cementing zirconia-yttria restorations, the purpose of this study was to perform an ex vivo assessment of the retention by frictional strength of Procera® zirconia-yttria systems cemented with four materials: Ketac Cem...
- Autores:
-
Mejía Bravo, Richard Milton
Caparroso Pérez, Carlos Bernardo
Ruiz Restrepo, Xiomara Cristina
Espitia Mesa, José Fernando
Moreno Castillo, Jenny Alexandra
Montoya Sepúlveda, Andrés Felipe
- Tipo de recurso:
- Article of investigation
- Fecha de publicación:
- 2014
- Institución:
- Universidad de Antioquia
- Repositorio:
- Repositorio UdeA
- Idioma:
- spa
- OAI Identifier:
- oai:bibliotecadigital.udea.edu.co:10495/4412
- Acceso en línea:
- http://hdl.handle.net/10495/4412
- Palabra clave:
- Porcelana dental
Cementos dentales
Retención de la prótesis
- Rights
- openAccess
- License
- Atribución-NoComercial-CompartirIgual 2.5 Colombia (CC BY-NC-SA 2.5 CO)
Summary: | ABSTRACT: Since the specialized literature does not report reliable protocols for cementing zirconia-yttria restorations, the purpose of this study was to perform an ex vivo assessment of the retention by frictional strength of Procera® zirconia-yttria systems cemented with four materials: Ketac Cem (3M) ESPE), Multilink Automix (Ivoclar Vivadent), Panavia F 2.0 (Kuraray), and RelyX U100 (3M ESPE) on natural teeth. Methods: We gathered 40 recently extracted third molars, which were disinfected with 0.5% NaOCl and stored in saline solution, embedded in acrylic resin, and cut at a 10° convergence angle per wall with an axial carving of 1.5 mm in depth and 4 mm in height. Impressions were taken with Aquasil Ultra® Dentsply and cast with type IV plaster, obtaining 40 Procera AllZircon (Nobel Biocare) structures. 10 samples per material were cemented and thermocycled x 5,000 cycles of 15 s. They were then tractioned with a universal testing machine and failure types at the different interfaces were analyzed. One-way multiple-range ANOVA statistical analysis was performed. Results: average retention values in Newtons were 440 N for Ketac Cem, 698 N for Multilink Automix, 686 N for Panavia F 2.0, and 551 N for RelyX U100. Dentin adhesion failure occurred in 53.8% of cases, followed by mixed failure, with 12.82%. Conclusions: resinous cements with acid phosphate monomers reported higher retention values in comparison with conventional acid-base cements. Adherence to dentin and cement handling can affect the final result. |
---|