Revisión Bibliográfica: Determinar los factores biomecánicos de la córnea relacionados con la aparición del Queratocono
Many studies have been done on keratoconus, however, the vast majority of these have been based on side effects in cornea, which makes it almost impossible to determine the cause of keratoconus. This review collects information on research conducted with state-of-the-art equipment, which has made it...
- Autores:
-
JIMENEZ RAMIREZ, JOSE FERNANDO
- Tipo de recurso:
- Trabajo de grado de pregrado
- Fecha de publicación:
- 2021
- Institución:
- Universidad Antonio Nariño
- Repositorio:
- Repositorio UAN
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.uan.edu.co:123456789/6641
- Acceso en línea:
- http://repositorio.uan.edu.co/handle/123456789/6641
- Palabra clave:
- Queratocono
Histéresis corneal
Espesor corneal
617.7
Keratoconus
Corneal hysteresis
Corneal thickness
- Rights
- openAccess
- License
- Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)
id |
UAntonioN2_c00fb0cd03fc8b70c9c8cfc3ad1140e6 |
---|---|
oai_identifier_str |
oai:repositorio.uan.edu.co:123456789/6641 |
network_acronym_str |
UAntonioN2 |
network_name_str |
Repositorio UAN |
repository_id_str |
|
dc.title.es_ES.fl_str_mv |
Revisión Bibliográfica: Determinar los factores biomecánicos de la córnea relacionados con la aparición del Queratocono |
title |
Revisión Bibliográfica: Determinar los factores biomecánicos de la córnea relacionados con la aparición del Queratocono |
spellingShingle |
Revisión Bibliográfica: Determinar los factores biomecánicos de la córnea relacionados con la aparición del Queratocono Queratocono Histéresis corneal Espesor corneal 617.7 Keratoconus Corneal hysteresis Corneal thickness |
title_short |
Revisión Bibliográfica: Determinar los factores biomecánicos de la córnea relacionados con la aparición del Queratocono |
title_full |
Revisión Bibliográfica: Determinar los factores biomecánicos de la córnea relacionados con la aparición del Queratocono |
title_fullStr |
Revisión Bibliográfica: Determinar los factores biomecánicos de la córnea relacionados con la aparición del Queratocono |
title_full_unstemmed |
Revisión Bibliográfica: Determinar los factores biomecánicos de la córnea relacionados con la aparición del Queratocono |
title_sort |
Revisión Bibliográfica: Determinar los factores biomecánicos de la córnea relacionados con la aparición del Queratocono |
dc.creator.fl_str_mv |
JIMENEZ RAMIREZ, JOSE FERNANDO |
dc.contributor.advisor.spa.fl_str_mv |
Reyes Clavijo, Ligia Soraya |
dc.contributor.author.spa.fl_str_mv |
JIMENEZ RAMIREZ, JOSE FERNANDO |
dc.subject.es_ES.fl_str_mv |
Queratocono Histéresis corneal Espesor corneal |
topic |
Queratocono Histéresis corneal Espesor corneal 617.7 Keratoconus Corneal hysteresis Corneal thickness |
dc.subject.ddc.es_ES.fl_str_mv |
617.7 |
dc.subject.keyword.es_ES.fl_str_mv |
Keratoconus Corneal hysteresis Corneal thickness |
description |
Many studies have been done on keratoconus, however, the vast majority of these have been based on side effects in cornea, which makes it almost impossible to determine the cause of keratoconus. This review collects information on research conducted with state-of-the-art equipment, which has made it possible to reference new factors of corneal biomechanics, which previously could not be measured in vivo, because they have adequate equipment, and that determine that the originating factor of the Keratoconus is due in part to loss of stability of the components of corneal biomechanics. |
publishDate |
2021 |
dc.date.issued.spa.fl_str_mv |
2021-05-25 |
dc.date.accessioned.none.fl_str_mv |
2022-05-23T23:59:56Z |
dc.date.available.none.fl_str_mv |
2022-05-23T23:59:56Z |
dc.type.spa.fl_str_mv |
Trabajo de grado (Pregrado y/o Especialización) |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_7a1f |
dc.type.coarversion.none.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
format |
http://purl.org/coar/resource_type/c_7a1f |
dc.identifier.uri.none.fl_str_mv |
http://repositorio.uan.edu.co/handle/123456789/6641 |
dc.identifier.bibliographicCitation.spa.fl_str_mv |
1. Zaky AG, Faisal Ellakwa A, Basiony AI. El grosor corneal central (CCT) es un factor biométrico [1] con un amplio rango de variabilidad en ojos sanos, cuya causa se cree que es el resultado de diferentes cantidades de colfibrillas de lagen y sustancia interfibrilar en la matriz estromal corne. 2021 [cited 2021 Feb 27]; Available from: https://doi.org/10.1155/2021/6613143 2. Nishida T, Kojima T, Kataoka T, Isogai N, Yoshida Y, Nakamura T. Evaluation of Biomechanically Corrected Intraocular Pressure Measurements in Keratoconus and Forme Fruste Keratoconus. Ophthalmic Res [Internet]. 2020 Dec 1 [cited 2021 Feb 27];63(6):541–9. Available from: https://www.karger.com/Article/FullText/506839 3. Zhang B, Shweikh Y, Khawaja AP, Gallacher J, Bauermeister S, Foster PJ, et al. Associations with Corneal Hysteresis in a Population Cohort: Results from 96 010 UK Biobank Participants. Ophthalmology [Internet]. 2019 Nov 1 [cited 2021 Feb 28];126(11):1500–10. Available from: http://www.aaojournal.org/article/S0161642019307249/fulltext orneal biomechanical assessment using corneal visualization scheimpflug technology in keratoconic and normal eyes. J Ophthalmol [Internet]. 2014 [cited 2020 Sep 24];2014. Available from: /pmc/articles/PMC3988970/?report=abstract 4. Jiang X, Dellepiane N, Pairo-Castineira E, Boutin T, Kumar Y, Bickmore WA, et al. Fine-mapping and cell-specific enrichment at corneal resistance factor loci prioritize candidate causal regulatory variants. Commun Biol. 2020 Dec 1;3(1). 5. Sedaghat M-R, Momeni-Moghaddam H, Azimi A, Fakhimi Z, Ziaei M, Danesh Z, et al. Corneal Biomechanical Properties in Varying Severities of Myopia. Front Bioeng Biotechnol [Internet]. 2021 Jan 21 [cited 2021 Mar 1];8:595330. Available from: https://www.frontiersin.org/articles/10.3389/fbioe.2020.595330/full 6. He M, Ding H, He H, Zhang C, Liu L, Zhong X. Corneal biomechanical properties in healthy children measured by corneal visualization scheimpflug technology. 7. Tian L, Huang YF, Wang LQ, Bai H, Wang Q, Jiang JJ, et al. C 8. Ionescu IC, Corbu CG, Nicula C, Coviltir V, Potop V, Constantin M, et al. The importance of corneal biomechanics in assessing first degree family members of keratoconus patients. Rom J Ophthalmol. 2018;61(2):149–54. 9. Villa C SJ. La córnea. Parte I Estructura, función y anatomía microscópica. Gac Opt. 2003;454:1–5. 10. María Ángeles del Buey Sayas. Estudio de la biomecánica corneal: relación entre las propiedades Biomecánicas Corneales, determinadas mediante el analizador de respuesta ocular ora y la patología ocular. Cirugía, Ginecol y Obstet Univ Zaragoza. 2013;343–4. |
dc.identifier.instname.spa.fl_str_mv |
instname:Universidad Antonio Nariño |
dc.identifier.reponame.spa.fl_str_mv |
reponame:Repositorio Institucional UAN |
dc.identifier.repourl.spa.fl_str_mv |
repourl:https://repositorio.uan.edu.co/ |
url |
http://repositorio.uan.edu.co/handle/123456789/6641 |
identifier_str_mv |
1. Zaky AG, Faisal Ellakwa A, Basiony AI. El grosor corneal central (CCT) es un factor biométrico [1] con un amplio rango de variabilidad en ojos sanos, cuya causa se cree que es el resultado de diferentes cantidades de colfibrillas de lagen y sustancia interfibrilar en la matriz estromal corne. 2021 [cited 2021 Feb 27]; Available from: https://doi.org/10.1155/2021/6613143 2. Nishida T, Kojima T, Kataoka T, Isogai N, Yoshida Y, Nakamura T. Evaluation of Biomechanically Corrected Intraocular Pressure Measurements in Keratoconus and Forme Fruste Keratoconus. Ophthalmic Res [Internet]. 2020 Dec 1 [cited 2021 Feb 27];63(6):541–9. Available from: https://www.karger.com/Article/FullText/506839 3. Zhang B, Shweikh Y, Khawaja AP, Gallacher J, Bauermeister S, Foster PJ, et al. Associations with Corneal Hysteresis in a Population Cohort: Results from 96 010 UK Biobank Participants. Ophthalmology [Internet]. 2019 Nov 1 [cited 2021 Feb 28];126(11):1500–10. Available from: http://www.aaojournal.org/article/S0161642019307249/fulltext orneal biomechanical assessment using corneal visualization scheimpflug technology in keratoconic and normal eyes. J Ophthalmol [Internet]. 2014 [cited 2020 Sep 24];2014. Available from: /pmc/articles/PMC3988970/?report=abstract 4. Jiang X, Dellepiane N, Pairo-Castineira E, Boutin T, Kumar Y, Bickmore WA, et al. Fine-mapping and cell-specific enrichment at corneal resistance factor loci prioritize candidate causal regulatory variants. Commun Biol. 2020 Dec 1;3(1). 5. Sedaghat M-R, Momeni-Moghaddam H, Azimi A, Fakhimi Z, Ziaei M, Danesh Z, et al. Corneal Biomechanical Properties in Varying Severities of Myopia. Front Bioeng Biotechnol [Internet]. 2021 Jan 21 [cited 2021 Mar 1];8:595330. Available from: https://www.frontiersin.org/articles/10.3389/fbioe.2020.595330/full 6. He M, Ding H, He H, Zhang C, Liu L, Zhong X. Corneal biomechanical properties in healthy children measured by corneal visualization scheimpflug technology. 7. Tian L, Huang YF, Wang LQ, Bai H, Wang Q, Jiang JJ, et al. C 8. Ionescu IC, Corbu CG, Nicula C, Coviltir V, Potop V, Constantin M, et al. The importance of corneal biomechanics in assessing first degree family members of keratoconus patients. Rom J Ophthalmol. 2018;61(2):149–54. 9. Villa C SJ. La córnea. Parte I Estructura, función y anatomía microscópica. Gac Opt. 2003;454:1–5. 10. María Ángeles del Buey Sayas. Estudio de la biomecánica corneal: relación entre las propiedades Biomecánicas Corneales, determinadas mediante el analizador de respuesta ocular ora y la patología ocular. Cirugía, Ginecol y Obstet Univ Zaragoza. 2013;343–4. instname:Universidad Antonio Nariño reponame:Repositorio Institucional UAN repourl:https://repositorio.uan.edu.co/ |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.rights.none.fl_str_mv |
Acceso abierto |
dc.rights.license.spa.fl_str_mv |
Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) |
dc.rights.uri.spa.fl_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.coar.spa.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
rights_invalid_str_mv |
Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) Acceso abierto https://creativecommons.org/licenses/by-nc-sa/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.publisher.spa.fl_str_mv |
Universidad Antonio Nariño |
dc.publisher.program.spa.fl_str_mv |
Optometría |
dc.publisher.faculty.spa.fl_str_mv |
Facultad de Optometría |
dc.publisher.campus.spa.fl_str_mv |
Bogotá - Circunvalar |
institution |
Universidad Antonio Nariño |
bitstream.url.fl_str_mv |
https://repositorio.uan.edu.co/bitstreams/03364235-5e07-43b5-826b-158a068ff73d/download https://repositorio.uan.edu.co/bitstreams/cbce0843-551a-491d-916e-3956ca21de66/download https://repositorio.uan.edu.co/bitstreams/f0b25cb3-c90d-4089-a326-df6134d98931/download https://repositorio.uan.edu.co/bitstreams/9bead027-66e8-492e-a89c-e572329b72da/download |
bitstream.checksum.fl_str_mv |
80294ba9ff4c5b4f07812ee200fbc42f 36c39ab62e4f766db4a7fd62fb2d871e c6de1a436dd51fd598ed8f12d812de69 009b654e562a6751f289b222292fe0fd |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional UAN |
repository.mail.fl_str_mv |
alertas.repositorio@uan.edu.co |
_version_ |
1814300434177720320 |
spelling |
Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)Acceso abiertohttps://creativecommons.org/licenses/by-nc-sa/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Reyes Clavijo, Ligia SorayaJIMENEZ RAMIREZ, JOSE FERNANDO102718297182022-05-23T23:59:56Z2022-05-23T23:59:56Z2021-05-25http://repositorio.uan.edu.co/handle/123456789/66411. Zaky AG, Faisal Ellakwa A, Basiony AI. El grosor corneal central (CCT) es un factor biométrico [1] con un amplio rango de variabilidad en ojos sanos, cuya causa se cree que es el resultado de diferentes cantidades de colfibrillas de lagen y sustancia interfibrilar en la matriz estromal corne. 2021 [cited 2021 Feb 27]; Available from: https://doi.org/10.1155/2021/66131432. Nishida T, Kojima T, Kataoka T, Isogai N, Yoshida Y, Nakamura T. Evaluation of Biomechanically Corrected Intraocular Pressure Measurements in Keratoconus and Forme Fruste Keratoconus. Ophthalmic Res [Internet]. 2020 Dec 1 [cited 2021 Feb 27];63(6):541–9. Available from: https://www.karger.com/Article/FullText/5068393. Zhang B, Shweikh Y, Khawaja AP, Gallacher J, Bauermeister S, Foster PJ, et al. Associations with Corneal Hysteresis in a Population Cohort: Results from 96 010 UK Biobank Participants. Ophthalmology [Internet]. 2019 Nov 1 [cited 2021 Feb 28];126(11):1500–10. Available from: http://www.aaojournal.org/article/S0161642019307249/fulltext orneal biomechanical assessment using corneal visualization scheimpflug technology in keratoconic and normal eyes. J Ophthalmol [Internet]. 2014 [cited 2020 Sep 24];2014. Available from: /pmc/articles/PMC3988970/?report=abstract4. Jiang X, Dellepiane N, Pairo-Castineira E, Boutin T, Kumar Y, Bickmore WA, et al. Fine-mapping and cell-specific enrichment at corneal resistance factor loci prioritize candidate causal regulatory variants. Commun Biol. 2020 Dec 1;3(1).5. Sedaghat M-R, Momeni-Moghaddam H, Azimi A, Fakhimi Z, Ziaei M, Danesh Z, et al. Corneal Biomechanical Properties in Varying Severities of Myopia. Front Bioeng Biotechnol [Internet]. 2021 Jan 21 [cited 2021 Mar 1];8:595330. Available from: https://www.frontiersin.org/articles/10.3389/fbioe.2020.595330/full6. He M, Ding H, He H, Zhang C, Liu L, Zhong X. Corneal biomechanical properties in healthy children measured by corneal visualization scheimpflug technology.7. Tian L, Huang YF, Wang LQ, Bai H, Wang Q, Jiang JJ, et al. C8. Ionescu IC, Corbu CG, Nicula C, Coviltir V, Potop V, Constantin M, et al. The importance of corneal biomechanics in assessing first degree family members of keratoconus patients. Rom J Ophthalmol. 2018;61(2):149–54.9. Villa C SJ. La córnea. Parte I Estructura, función y anatomía microscópica. Gac Opt. 2003;454:1–5.10. María Ángeles del Buey Sayas. Estudio de la biomecánica corneal: relación entre las propiedades Biomecánicas Corneales, determinadas mediante el analizador de respuesta ocular ora y la patología ocular. Cirugía, Ginecol y Obstet Univ Zaragoza. 2013;343–4.instname:Universidad Antonio Nariñoreponame:Repositorio Institucional UANrepourl:https://repositorio.uan.edu.co/Many studies have been done on keratoconus, however, the vast majority of these have been based on side effects in cornea, which makes it almost impossible to determine the cause of keratoconus. This review collects information on research conducted with state-of-the-art equipment, which has made it possible to reference new factors of corneal biomechanics, which previously could not be measured in vivo, because they have adequate equipment, and that determine that the originating factor of the Keratoconus is due in part to loss of stability of the components of corneal biomechanics.Se han realizados muchos estudios sobre el queratocono, sin embargo, la gran mayoría de estos, se han basado sobre los efectos secundarios en córnea, lo que hace casi imposible determinar el porqué del queratocono. Esta revisión recopila información, sobre investigaciones realizadas con equipos de última tecnología, que han permitido referenciar nuevos factores de la biomecánica corneal, que antes no podían ser medidos in vivo, por no disponer del equipo adecuado, y que determinan que el factor originario del queratocono se debe en parte a la pérdida de la estabilidad de los componentes de la biomecánica corneal.OptómetraPregradoDistanciaMonografíaspaUniversidad Antonio NariñoOptometríaFacultad de OptometríaBogotá - CircunvalarQueratoconoHistéresis cornealEspesor corneal617.7KeratoconusCorneal hysteresisCorneal thicknessRevisión Bibliográfica: Determinar los factores biomecánicos de la córnea relacionados con la aparición del QueratoconoTrabajo de grado (Pregrado y/o Especialización)http://purl.org/coar/resource_type/c_7a1fhttp://purl.org/coar/version/c_970fb48d4fbd8a85EspecializadaCC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-81037https://repositorio.uan.edu.co/bitstreams/03364235-5e07-43b5-826b-158a068ff73d/download80294ba9ff4c5b4f07812ee200fbc42fMD54ORIGINAL2021_JoséFernandoJiménezRamírez_Acta.pdf2021_JoséFernandoJiménezRamírez_Acta.pdfapplication/pdf169847https://repositorio.uan.edu.co/bitstreams/cbce0843-551a-491d-916e-3956ca21de66/download36c39ab62e4f766db4a7fd62fb2d871eMD512021_JoséFernandoJiménezRamírez.pdf2021_JoséFernandoJiménezRamírez.pdfapplication/pdf807195https://repositorio.uan.edu.co/bitstreams/f0b25cb3-c90d-4089-a326-df6134d98931/downloadc6de1a436dd51fd598ed8f12d812de69MD522021_JoséFernandoJiménezRamírez_Autorización.pdf2021_JoséFernandoJiménezRamírez_Autorización.pdfapplication/pdf311355https://repositorio.uan.edu.co/bitstreams/9bead027-66e8-492e-a89c-e572329b72da/download009b654e562a6751f289b222292fe0fdMD53123456789/6641oai:repositorio.uan.edu.co:123456789/66412024-10-09 23:23:06.55https://creativecommons.org/licenses/by-nc-sa/4.0/Acceso abiertorestrictedhttps://repositorio.uan.edu.coRepositorio Institucional UANalertas.repositorio@uan.edu.co |