Mathematical model to determine the Coagulation Time Human Blood from Experimental Data
In this paper a linear mathematical model of first order with delay is presented to characterize the clotting time of blood from experimental data obtained by the technique of dynamic speckle. The experimental platform used has a CCD camera, a He-Ne laser and a computer for recording and processing...
- Autores:
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2015
- Institución:
- Universidad Antonio Nariño
- Repositorio:
- Repositorio UAN
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.uan.edu.co:123456789/10459
- Acceso en línea:
- https://revistas.uan.edu.co/index.php/ingeuan/article/view/391
https://repositorio.uan.edu.co/handle/123456789/10459
- Palabra clave:
- Coagulación
Modelos
Señales
Sistemas dinámicos
Coagulation
Models
Signals
Dynamic Systems
- Rights
- License
- https://creativecommons.org/licenses/by-nc-sa/4.0
id |
UAntonioN2_b3e1742929e867192533a399eb767663 |
---|---|
oai_identifier_str |
oai:repositorio.uan.edu.co:123456789/10459 |
network_acronym_str |
UAntonioN2 |
network_name_str |
Repositorio UAN |
repository_id_str |
|
spelling |
2015-10-082024-10-10T02:25:17Z2024-10-10T02:25:17Zhttps://revistas.uan.edu.co/index.php/ingeuan/article/view/391https://repositorio.uan.edu.co/handle/123456789/10459In this paper a linear mathematical model of first order with delay is presented to characterize the clotting time of blood from experimental data obtained by the technique of dynamic speckle. The experimental platform used has a CCD camera, a He-Ne laser and a computer for recording and processing information. Experimental results are presented, analysis and development of an automatic control system to validate the proposed medical treatment aimed at reducing the coagulation time of bloodEn este trabajo se presenta un modelo matemático lineal de primer orden con retardo, para caracterizar el tiempo de coagulación de la sangre a partir de datos obtenidos mediante la técnica de speckle dinámico. La plataforma experimental utilizada dispone de una cámara CCD, un láser de He-Ne y un computador para el registro y procesamiento de la información. Se presentan los resultados experimentales obtenidos, su análisis y se propone el desarrollo de un sistema de control para validar el tratamiento médico enfocado a reducir el tiempo de coagulación de la sangre.application/pdfspaUNIVERSIDAD ANTONIO NARIÑOhttps://revistas.uan.edu.co/index.php/ingeuan/article/view/391/330https://creativecommons.org/licenses/by-nc-sa/4.0http://purl.org/coar/access_right/c_abf2INGE@UAN - TENDENCIAS EN LA INGENIERÍA; Vol. 5 Núm. 10 (2015)2346-14462145-0935CoagulaciónModelosSeñalesSistemas dinámicosCoagulationModelsSignalsDynamic SystemsMathematical model to determine the Coagulation Time Human Blood from Experimental DataModelo Matemático para determinar el Tiempo de Coagulación de la Sangre Humana a partir de Datos Experimentalesinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85Bravo M., Diego A.Patiño V., Mario M.Pencue F., Leonairo123456789/10459oai:repositorio.uan.edu.co:123456789/104592024-10-14 03:48:21.352metadata.onlyhttps://repositorio.uan.edu.coRepositorio Institucional UANalertas.repositorio@uan.edu.co |
dc.title.en-US.fl_str_mv |
Mathematical model to determine the Coagulation Time Human Blood from Experimental Data |
dc.title.es-ES.fl_str_mv |
Modelo Matemático para determinar el Tiempo de Coagulación de la Sangre Humana a partir de Datos Experimentales |
title |
Mathematical model to determine the Coagulation Time Human Blood from Experimental Data |
spellingShingle |
Mathematical model to determine the Coagulation Time Human Blood from Experimental Data Coagulación Modelos Señales Sistemas dinámicos Coagulation Models Signals Dynamic Systems |
title_short |
Mathematical model to determine the Coagulation Time Human Blood from Experimental Data |
title_full |
Mathematical model to determine the Coagulation Time Human Blood from Experimental Data |
title_fullStr |
Mathematical model to determine the Coagulation Time Human Blood from Experimental Data |
title_full_unstemmed |
Mathematical model to determine the Coagulation Time Human Blood from Experimental Data |
title_sort |
Mathematical model to determine the Coagulation Time Human Blood from Experimental Data |
dc.subject.es-ES.fl_str_mv |
Coagulación Modelos Señales Sistemas dinámicos |
topic |
Coagulación Modelos Señales Sistemas dinámicos Coagulation Models Signals Dynamic Systems |
dc.subject.en-US.fl_str_mv |
Coagulation Models Signals Dynamic Systems |
description |
In this paper a linear mathematical model of first order with delay is presented to characterize the clotting time of blood from experimental data obtained by the technique of dynamic speckle. The experimental platform used has a CCD camera, a He-Ne laser and a computer for recording and processing information. Experimental results are presented, analysis and development of an automatic control system to validate the proposed medical treatment aimed at reducing the coagulation time of blood |
publishDate |
2015 |
dc.date.accessioned.none.fl_str_mv |
2024-10-10T02:25:17Z |
dc.date.available.none.fl_str_mv |
2024-10-10T02:25:17Z |
dc.date.none.fl_str_mv |
2015-10-08 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.coarversion.none.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.uan.edu.co/index.php/ingeuan/article/view/391 |
dc.identifier.uri.none.fl_str_mv |
https://repositorio.uan.edu.co/handle/123456789/10459 |
url |
https://revistas.uan.edu.co/index.php/ingeuan/article/view/391 https://repositorio.uan.edu.co/handle/123456789/10459 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.uan.edu.co/index.php/ingeuan/article/view/391/330 |
dc.rights.es-ES.fl_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0 |
dc.rights.coar.spa.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0 http://purl.org/coar/access_right/c_abf2 |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.es-ES.fl_str_mv |
UNIVERSIDAD ANTONIO NARIÑO |
dc.source.es-ES.fl_str_mv |
INGE@UAN - TENDENCIAS EN LA INGENIERÍA; Vol. 5 Núm. 10 (2015) |
dc.source.none.fl_str_mv |
2346-1446 2145-0935 |
institution |
Universidad Antonio Nariño |
repository.name.fl_str_mv |
Repositorio Institucional UAN |
repository.mail.fl_str_mv |
alertas.repositorio@uan.edu.co |
_version_ |
1814300319091261440 |