Application of Loop Automation in an overhead distribution network of medium voltage
Product to the affectations happened in the distribution circuits by the faults happened in its the investigation arises: Application of the Loop Automation in a net of distribution of half tension, looking for design a system of protection that is able to isolate the fault in the smallest tract in...
- Autores:
-
Miraglia Núñez, Dante
Mirez Tarrillo, Jorge
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2015
- Institución:
- Universidad Antonio Nariño
- Repositorio:
- Repositorio UAN
- Idioma:
- spa
- OAI Identifier:
- oai:repositorio.uan.edu.co:123456789/3955
- Acceso en línea:
- http://revistas.uan.edu.co/index.php/ingeuan/article/view/392
http://repositorio.uan.edu.co/handle/123456789/3955
- Palabra clave:
- distribution circuits
Nulec
electric protection
Loop Automation
circuitos de distribución
Nulec
protecciones eléctricas
Loop Automation
- Rights
- openAccess
- License
- Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)
id |
UAntonioN2_8e02306b10b0734e451fc8d50aba4841 |
---|---|
oai_identifier_str |
oai:repositorio.uan.edu.co:123456789/3955 |
network_acronym_str |
UAntonioN2 |
network_name_str |
Repositorio UAN |
repository_id_str |
|
spelling |
Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0)Acceso abiertohttps://creativecommons.org/licenses/by-nc-sa/4.0/info:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Miraglia Núñez, DanteMirez Tarrillo, Jorge2021-06-16T13:53:13Z2021-06-16T13:53:13Z2015-10-08http://revistas.uan.edu.co/index.php/ingeuan/article/view/392http://repositorio.uan.edu.co/handle/123456789/3955Product to the affectations happened in the distribution circuits by the faults happened in its the investigation arises: Application of the Loop Automation in a net of distribution of half tension, looking for design a system of protection that is able to isolate the fault in the smallest tract in the possible circuit, avoiding a high number of clients so is affected. In the work is carried out a brief description of the protection commonly used in the distribution systems demonstrating as these they are not able to limit the fault to the smallest possible area, and of how that is possible using the recloser of Nulec working under the Loop Automation. Also, is proposed a work methodology that facilitates the design of this system of protection getting in the analyzed circuits the faults affect to the smallest number of clients.Producto de las afectaciones ocurridas en los circuitos de distribución cuando ocurren fallas surge la investigación: Implementación del Aplicación del Loop Automation en una red de distribución de media tensión, buscando diseñar un sistema de protección capaz de aislar las fallas en el menor tramo posible del circuito afectando, es decir, al menor número de clientes posibles. En el trabajo se realiza una breve descripción de las protecciones comúnmente usadas en los sistemas de distribución demostrando como estas no son capaces de limitar la falla a la menor área posible y como esto se logra usando los reconectadores de Nulec trabajando como parte del esquema Loop Automation. Además se propone una metodología de trabajo que facilite el diseño de este sistema de protecciones obteniendo que en el circuito analizado las fallas ocurridas afecten al menor número de clientes posibles.application/pdfspaUniversidad Antonio Nariñohttp://revistas.uan.edu.co/index.php/ingeuan/article/view/392/3312346-14462145-0935INGE@UAN - TENDENCIAS EN LA INGENIERÍA; Vol. 5 Núm. 10 (2015)distribution circuitsNulecelectric protectionLoop Automationcircuitos de distribuciónNulecprotecciones eléctricasLoop AutomationApplication of Loop Automation in an overhead distribution network of medium voltageAplicación del Loop Automation en una red de distribución aérea de media tensióninfo:eu-repo/semantics/publishedVersionhttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1info:eu-repo/semantics/articlehttp://purl.org/coar/version/c_970fb48d4fbd8a85123456789/3955oai:repositorio.uan.edu.co:123456789/39552024-10-09 22:56:49.937https://creativecommons.org/licenses/by-nc-sa/4.0/Acceso abiertometadata.onlyhttps://repositorio.uan.edu.coRepositorio Institucional UANalertas.repositorio@uan.edu.co |
dc.title.en-US.fl_str_mv |
Application of Loop Automation in an overhead distribution network of medium voltage |
dc.title.es-ES.fl_str_mv |
Aplicación del Loop Automation en una red de distribución aérea de media tensión |
title |
Application of Loop Automation in an overhead distribution network of medium voltage |
spellingShingle |
Application of Loop Automation in an overhead distribution network of medium voltage distribution circuits Nulec electric protection Loop Automation circuitos de distribución Nulec protecciones eléctricas Loop Automation |
title_short |
Application of Loop Automation in an overhead distribution network of medium voltage |
title_full |
Application of Loop Automation in an overhead distribution network of medium voltage |
title_fullStr |
Application of Loop Automation in an overhead distribution network of medium voltage |
title_full_unstemmed |
Application of Loop Automation in an overhead distribution network of medium voltage |
title_sort |
Application of Loop Automation in an overhead distribution network of medium voltage |
dc.creator.fl_str_mv |
Miraglia Núñez, Dante Mirez Tarrillo, Jorge |
dc.contributor.author.spa.fl_str_mv |
Miraglia Núñez, Dante Mirez Tarrillo, Jorge |
dc.subject.en-US.fl_str_mv |
distribution circuits Nulec electric protection Loop Automation |
topic |
distribution circuits Nulec electric protection Loop Automation circuitos de distribución Nulec protecciones eléctricas Loop Automation |
dc.subject.es-ES.fl_str_mv |
circuitos de distribución Nulec protecciones eléctricas Loop Automation |
description |
Product to the affectations happened in the distribution circuits by the faults happened in its the investigation arises: Application of the Loop Automation in a net of distribution of half tension, looking for design a system of protection that is able to isolate the fault in the smallest tract in the possible circuit, avoiding a high number of clients so is affected. In the work is carried out a brief description of the protection commonly used in the distribution systems demonstrating as these they are not able to limit the fault to the smallest possible area, and of how that is possible using the recloser of Nulec working under the Loop Automation. Also, is proposed a work methodology that facilitates the design of this system of protection getting in the analyzed circuits the faults affect to the smallest number of clients. |
publishDate |
2015 |
dc.date.issued.spa.fl_str_mv |
2015-10-08 |
dc.date.accessioned.none.fl_str_mv |
2021-06-16T13:53:13Z |
dc.date.available.none.fl_str_mv |
2021-06-16T13:53:13Z |
dc.type.coar.fl_str_mv |
http://purl.org/coar/resource_type/c_2df8fbb1 |
dc.type.version.spa.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.coar.spa.fl_str_mv |
http://purl.org/coar/resource_type/c_6501 |
dc.type.driver.spa.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.coarversion.none.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a85 |
format |
http://purl.org/coar/resource_type/c_6501 |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
http://revistas.uan.edu.co/index.php/ingeuan/article/view/392 |
dc.identifier.uri.none.fl_str_mv |
http://repositorio.uan.edu.co/handle/123456789/3955 |
url |
http://revistas.uan.edu.co/index.php/ingeuan/article/view/392 http://repositorio.uan.edu.co/handle/123456789/3955 |
dc.language.iso.spa.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
http://revistas.uan.edu.co/index.php/ingeuan/article/view/392/331 |
dc.rights.none.fl_str_mv |
Acceso abierto |
dc.rights.license.spa.fl_str_mv |
Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) |
dc.rights.uri.spa.fl_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0/ |
dc.rights.accessrights.spa.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.coar.spa.fl_str_mv |
http://purl.org/coar/access_right/c_abf2 |
rights_invalid_str_mv |
Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) Acceso abierto https://creativecommons.org/licenses/by-nc-sa/4.0/ http://purl.org/coar/access_right/c_abf2 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.spa.fl_str_mv |
Universidad Antonio Nariño |
dc.source.none.fl_str_mv |
2346-1446 2145-0935 |
dc.source.es-ES.fl_str_mv |
INGE@UAN - TENDENCIAS EN LA INGENIERÍA; Vol. 5 Núm. 10 (2015) |
institution |
Universidad Antonio Nariño |
repository.name.fl_str_mv |
Repositorio Institucional UAN |
repository.mail.fl_str_mv |
alertas.repositorio@uan.edu.co |
_version_ |
1814300364873138176 |