Comparación entre el módulo resiliente de la subrasante determinado en laboratorio y el retrocaculado, factor de ajuste C

The main objective of this article is to understand the relationship between the Subgrade Resilient Retrocalculated Module (Mrr), given from the information provided by the Impact Deflectometer (FWD), and that obtained from the lab results (Mr), which is given by the designated adjustment factor “C”...

Full description

Autores:
Guzmán-Suárez, Edwin Antonio
Higuera-Sandoval, Carlos Hernando
Tipo de recurso:
Fecha de publicación:
2016
Institución:
Universidad Santo Tomás
Repositorio:
Universidad Santo Tomás
Idioma:
spa
OAI Identifier:
oai:repository.usta.edu.co:11634/5014
Acceso en línea:
http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/1167
http://hdl.handle.net/11634/5014
Palabra clave:
Impact deflectometer
Adjustment factor
Resilient module
Retrocalcualtion
Deflectómetro de impacto
Factor de ajuste
Módulo resiliente
Retrocálculo
Deflectómetro de impacto
Fator de ajuste
Módulo resiliente
Retrocálculo
Rights
License
Copyright (c) 2016 Ingenio Magno
id SantoToma2_8c3ddf2b7fae61c86a401dfded5cd16e
oai_identifier_str oai:repository.usta.edu.co:11634/5014
network_acronym_str SantoToma2
network_name_str Universidad Santo Tomás
repository_id_str
dc.title.spa.fl_str_mv Comparación entre el módulo resiliente de la subrasante determinado en laboratorio y el retrocaculado, factor de ajuste C
dc.title.alternative.eng.fl_str_mv Comparison between the subgrade resilient module determined in the laboratory and retrocaculated adjustment factor C
dc.title.alternative.por.fl_str_mv Comparativo entre o módulo resiliente do subleito determinado no laboratório e o retrocalculado-fator de ajuste C
title Comparación entre el módulo resiliente de la subrasante determinado en laboratorio y el retrocaculado, factor de ajuste C
spellingShingle Comparación entre el módulo resiliente de la subrasante determinado en laboratorio y el retrocaculado, factor de ajuste C
Impact deflectometer
Adjustment factor
Resilient module
Retrocalcualtion
Deflectómetro de impacto
Factor de ajuste
Módulo resiliente
Retrocálculo
Deflectómetro de impacto
Fator de ajuste
Módulo resiliente
Retrocálculo
title_short Comparación entre el módulo resiliente de la subrasante determinado en laboratorio y el retrocaculado, factor de ajuste C
title_full Comparación entre el módulo resiliente de la subrasante determinado en laboratorio y el retrocaculado, factor de ajuste C
title_fullStr Comparación entre el módulo resiliente de la subrasante determinado en laboratorio y el retrocaculado, factor de ajuste C
title_full_unstemmed Comparación entre el módulo resiliente de la subrasante determinado en laboratorio y el retrocaculado, factor de ajuste C
title_sort Comparación entre el módulo resiliente de la subrasante determinado en laboratorio y el retrocaculado, factor de ajuste C
dc.creator.fl_str_mv Guzmán-Suárez, Edwin Antonio
Higuera-Sandoval, Carlos Hernando
dc.contributor.author.spa.fl_str_mv Guzmán-Suárez, Edwin Antonio
Higuera-Sandoval, Carlos Hernando
dc.subject.proposal.eng.fl_str_mv Impact deflectometer
Adjustment factor
Resilient module
Retrocalcualtion
topic Impact deflectometer
Adjustment factor
Resilient module
Retrocalcualtion
Deflectómetro de impacto
Factor de ajuste
Módulo resiliente
Retrocálculo
Deflectómetro de impacto
Fator de ajuste
Módulo resiliente
Retrocálculo
dc.subject.proposal.spa.fl_str_mv Deflectómetro de impacto
Factor de ajuste
Módulo resiliente
Retrocálculo
dc.subject.proposal.por.fl_str_mv Deflectómetro de impacto
Fator de ajuste
Módulo resiliente
Retrocálculo
description The main objective of this article is to understand the relationship between the Subgrade Resilient Retrocalculated Module (Mrr), given from the information provided by the Impact Deflectometer (FWD), and that obtained from the lab results (Mr), which is given by the designated adjustment factor “C”. Initially, a structural evaluation of a length of flexible pavement was analyzed through FWD. The results characterized the resistance of the subgrade through the Resilient Module parameter. Using retro calculation techniques, the values of the Resilient Module determined in the laboratory tests were compared. This yielded an adjustment factor in order to make the module values obtained comparable. The analysis consisted of retrocalculating the Resilient Module in the subgrade through the implementation of different methods. Then, these results were compared to the results obtained from the Resilient Module in the laboratory determined under the conditions prevailing in the pavement structure in service. As a result of the correlation found, the variables Mrr y Mr were established. The analysis yielded the conclusion that there exists more than one factor to be applied on the Resilient Module of the retrocalucated subgrade. Also, the adjustment factor depends on the method which categorizes the resistance of the subgrade and the Resilient Module equation of the subgrade material tested in the laboratory.
publishDate 2016
dc.date.issued.spa.fl_str_mv 2016-08-29
dc.date.accessioned.spa.fl_str_mv 2017-09-16T15:58:17Z
dc.date.available.spa.fl_str_mv 2017-09-16T15:58:17Z
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.drive.none.fl_str_mv info:eu-repo/semantics/article
dc.identifier.spa.fl_str_mv http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/1167
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/11634/5014
url http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/1167
http://hdl.handle.net/11634/5014
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/1167/1131
dc.relation.citationissue.spa.fl_str_mv Ingenio Magno; Vol. 7 (2016): Ingenio Magno Vol. 7-1; 62-83
2422-2399
2145-9282
dc.rights.spa.fl_str_mv Copyright (c) 2016 Ingenio Magno
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Copyright (c) 2016 Ingenio Magno
http://purl.org/coar/access_right/c_abf2
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Santo Tomás Seccional Tunja
institution Universidad Santo Tomás
repository.name.fl_str_mv Repositorio Universidad Santo Tomás
repository.mail.fl_str_mv noreply@usta.edu.co
_version_ 1800786418136514560
spelling Guzmán-Suárez, Edwin AntonioHiguera-Sandoval, Carlos Hernando2017-09-16T15:58:17Z2017-09-16T15:58:17Z2016-08-29http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/1167http://hdl.handle.net/11634/5014The main objective of this article is to understand the relationship between the Subgrade Resilient Retrocalculated Module (Mrr), given from the information provided by the Impact Deflectometer (FWD), and that obtained from the lab results (Mr), which is given by the designated adjustment factor “C”. Initially, a structural evaluation of a length of flexible pavement was analyzed through FWD. The results characterized the resistance of the subgrade through the Resilient Module parameter. Using retro calculation techniques, the values of the Resilient Module determined in the laboratory tests were compared. This yielded an adjustment factor in order to make the module values obtained comparable. The analysis consisted of retrocalculating the Resilient Module in the subgrade through the implementation of different methods. Then, these results were compared to the results obtained from the Resilient Module in the laboratory determined under the conditions prevailing in the pavement structure in service. As a result of the correlation found, the variables Mrr y Mr were established. The analysis yielded the conclusion that there exists more than one factor to be applied on the Resilient Module of the retrocalucated subgrade. Also, the adjustment factor depends on the method which categorizes the resistance of the subgrade and the Resilient Module equation of the subgrade material tested in the laboratory.Este artículo busca conocer la relación existente entre el módulo resiliente de la subrasante retrocalculado (Mrr), a partir de la información del deflectómetro de impacto (FWD), y el obtenido en pruebas de laboratorio (Mr); relación que está dada por el denominado factor de ajuste “C”. Inicialmente, en este trabajo se ha realizado la evaluación estructural de un tramo de pavimento flexible mediante FWD. Los resultados de caracterizar la resistencia de la subrasante mediante el parámetro módulo resiliente, al aplicar técnicas de retrocálculo, han sido comparados con el valor del módulo resiliente determinado en las pruebas de laboratorio, y a partir de esta relación se han establecido factores de ajuste para hacer equiparables los valores de módulo obtenidos. El análisis efectuado consistió en retrocalcular el módulo resiliente de la subrasante mediante la implementación de diferentes métodos, para posteriormente contrastar estos resultados con el módulo resiliente de laboratorio, determinado bajo las condiciones imperantes en la estructura de pavimento en servicio. Como resultado, a partir de la relación encontrada, se establecen factores para hacer consistentes los valores de Mrr y Mr. A partir del análisis realizado se concluye que no existe un único factor por aplicar al módulo resiliente de la subrasante retrocalculado; el factor de ajuste es función del método con que se caracteriza la resistencia de la subrasante y de la ecuación constitutiva del módulo resiliente del material de subrasante ensayado en laboratorio.O objetivo principal neste artigo é conhecer a relação existente entre o módulo resiliente do subleito retrocalculado (Mrr), a partir da informação do Deflectómetro de impacto (FWD), obtido em ensaios de laboratório (Mr), dada pelo denominado fator de ajuste “C”. Inicialmente, neste trabalho foi realizada a avaliação estrutural de um trecho de asfalto flexível mediante FWD. Os resultados da caracterização da resistência do subleito mediante o parámetro módulo resiliente, aplicando técnicas de retrocálculo, foram comparados com o valor do módulo resiliente determinado nos ensaios de laboratório, e a partir da relação estabeleceram-se fatores de ajuste para fazer equiparáveis os valores do módulo obtidos. A análise realizada, consistiu em retrocalcular o módulo resiliente do subleito mediante a implementação dos diferentes métodos, para contrastar estes resultados com o módulo resiliente do laboratório, determinados sob as condições predominantes na estrutura do pavimento em serviço. Como resultado, a partir da relação encontrada estabeleceram-se fatores para fazer os valores consistentes Mrr e Mr. Da análise realizada, concluiu-se que não existe um único fator para aplicar ao módulo resiliente do subleito retrocalculado. O fator de ajuste é uma função do método utilizado para caracterizar a resistência do subleito e da equação do módulo resiliente do material do subleito testado no laboratório.application/pdfspaUniversidad Santo Tomás Seccional Tunjahttp://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/1167/1131Ingenio Magno; Vol. 7 (2016): Ingenio Magno Vol. 7-1; 62-832422-23992145-9282Copyright (c) 2016 Ingenio Magnohttp://purl.org/coar/access_right/c_abf2Comparación entre el módulo resiliente de la subrasante determinado en laboratorio y el retrocaculado, factor de ajuste CComparison between the subgrade resilient module determined in the laboratory and retrocaculated adjustment factor CComparativo entre o módulo resiliente do subleito determinado no laboratório e o retrocalculado-fator de ajuste Cinfo:eu-repo/semantics/articlehttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_2df8fbb1Impact deflectometerAdjustment factorResilient moduleRetrocalcualtionDeflectómetro de impactoFactor de ajusteMódulo resilienteRetrocálculoDeflectómetro de impactoFator de ajusteMódulo resilienteRetrocálculo11634/5014oai:repository.usta.edu.co:11634/50142023-07-14 16:34:14.093metadata only accessRepositorio Universidad Santo Tomásnoreply@usta.edu.co