MICROCHIP RFID PASIVO IMPLANTADO EN DIENTES MOLARES SOMETIDOS A ALTAS TEMPERATURAS CON FINES DE IDENTIFICACIÓN FORENSE

Objective: to assess In vitro behavior of a passive RFID microchip implanted in human molars and subjected to high temperatures to determine their resistance and performance.Methods: an experimental In vitro study was done to evaluate the behavior of a passive RFID microchip (VeriChip™) implanted in...

Full description

Autores:
Moreno Gómez, Freddy
Moreno Correa, Sandra Milena
Garzón Rayo, Herney
Tipo de recurso:
Fecha de publicación:
2013
Institución:
Universidad Santo Tomás
Repositorio:
Universidad Santo Tomás
Idioma:
spa
OAI Identifier:
oai:repository.usta.edu.co:11634/37078
Acceso en línea:
http://revistas.ustabuca.edu.co/index.php/USTASALUD_ODONTOLOGIA/article/view/1215
http://hdl.handle.net/11634/37078
Palabra clave:
Rights
License
Derechos de autor 2018 UstaSalud
id SantoToma2_2e43c0c7cdff1301f255fa21b80b8e9a
oai_identifier_str oai:repository.usta.edu.co:11634/37078
network_acronym_str SantoToma2
network_name_str Universidad Santo Tomás
repository_id_str
dc.title.spa.fl_str_mv MICROCHIP RFID PASIVO IMPLANTADO EN DIENTES MOLARES SOMETIDOS A ALTAS TEMPERATURAS CON FINES DE IDENTIFICACIÓN FORENSE
dc.title.alternative.eng.fl_str_mv IMPLANTED PASSIVE RFID MICROCHIPS IN MOLARS SUBJECTED TO HIGH TEMPERATURES WITH FORENSIC IDENTIFICATION PURPOSES
title MICROCHIP RFID PASIVO IMPLANTADO EN DIENTES MOLARES SOMETIDOS A ALTAS TEMPERATURAS CON FINES DE IDENTIFICACIÓN FORENSE
spellingShingle MICROCHIP RFID PASIVO IMPLANTADO EN DIENTES MOLARES SOMETIDOS A ALTAS TEMPERATURAS CON FINES DE IDENTIFICACIÓN FORENSE
title_short MICROCHIP RFID PASIVO IMPLANTADO EN DIENTES MOLARES SOMETIDOS A ALTAS TEMPERATURAS CON FINES DE IDENTIFICACIÓN FORENSE
title_full MICROCHIP RFID PASIVO IMPLANTADO EN DIENTES MOLARES SOMETIDOS A ALTAS TEMPERATURAS CON FINES DE IDENTIFICACIÓN FORENSE
title_fullStr MICROCHIP RFID PASIVO IMPLANTADO EN DIENTES MOLARES SOMETIDOS A ALTAS TEMPERATURAS CON FINES DE IDENTIFICACIÓN FORENSE
title_full_unstemmed MICROCHIP RFID PASIVO IMPLANTADO EN DIENTES MOLARES SOMETIDOS A ALTAS TEMPERATURAS CON FINES DE IDENTIFICACIÓN FORENSE
title_sort MICROCHIP RFID PASIVO IMPLANTADO EN DIENTES MOLARES SOMETIDOS A ALTAS TEMPERATURAS CON FINES DE IDENTIFICACIÓN FORENSE
dc.creator.fl_str_mv Moreno Gómez, Freddy
Moreno Correa, Sandra Milena
Garzón Rayo, Herney
dc.contributor.author.none.fl_str_mv Moreno Gómez, Freddy
Moreno Correa, Sandra Milena
Garzón Rayo, Herney
description Objective: to assess In vitro behavior of a passive RFID microchip implanted in human molars and subjected to high temperatures to determine their resistance and performance.Methods: an experimental In vitro study was done to evaluate the behavior of a passive RFID microchip (VeriChip™) implanted in 10 human molars with a composite restoration (Filtek P90™ Silorane 3M-ESPE®) in class I occlusal cavities and class V vestibular cavities and subjected to high temperatures (100 °C, 200 °C, 300 °C, 400 °C and 500 °C), in order to determine their resistance and performance. The specimens were observed through Digital Photography (DP), Stereomicroscopy (SM) and Scanning Electron Microscopy (SEM).Results: it was observed that passive RFID microchips have capacity to withstand high temperatures maintaining their macrostructural integrity, but they were observed cohesive and adhesive fractures that disrupt the mechanisms of adhesion between the dental tissues, the composite material and the microchip, and impairs its correct operation beyond 300 °C.Conclusions: passive RFID microchips implanted in human molars with a resin restoration resist the action of high temperatures without altering their macrostructure, however they only operated up to 300 °C, which eventually may contribute to the processes of forensic identification in case of burned, charred and incinerated bodies.
publishDate 2013
dc.date.issued.none.fl_str_mv 2013-07-01
dc.date.accessioned.none.fl_str_mv 2021-09-24T16:23:29Z
dc.date.available.none.fl_str_mv 2021-09-24T16:23:29Z
dc.type.spa.fl_str_mv Artículo revisado por pares
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.drive.none.fl_str_mv info:eu-repo/semantics/article
dc.identifier.none.fl_str_mv http://revistas.ustabuca.edu.co/index.php/USTASALUD_ODONTOLOGIA/article/view/1215
10.15332/us.v12i2.1215
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/11634/37078
url http://revistas.ustabuca.edu.co/index.php/USTASALUD_ODONTOLOGIA/article/view/1215
http://hdl.handle.net/11634/37078
identifier_str_mv 10.15332/us.v12i2.1215
dc.language.iso.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://revistas.ustabuca.edu.co/index.php/USTASALUD_ODONTOLOGIA/article/view/1215/1001
dc.relation.citationissue.spa.fl_str_mv Ustasalud; Vol. 12 Núm. 2 (2013); 116-123
dc.relation.citationissue.eng.fl_str_mv Ustasalud; Vol. 12 Núm. 2 (2013); 116-123
dc.relation.citationissue.none.fl_str_mv 2590-7875
1692-5106
10.15332/us.v12i2
dc.rights.spa.fl_str_mv Derechos de autor 2018 UstaSalud
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Derechos de autor 2018 UstaSalud
http://purl.org/coar/access_right/c_abf2
dc.format.mimetype.none.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Santo Tomás Seccional Bucaramanga
institution Universidad Santo Tomás
repository.name.fl_str_mv Repositorio Universidad Santo Tomás
repository.mail.fl_str_mv noreply@usta.edu.co
_version_ 1800786368825131008
spelling Moreno Gómez, FreddyMoreno Correa, Sandra MilenaGarzón Rayo, Herney2021-09-24T16:23:29Z2021-09-24T16:23:29Z2013-07-01http://revistas.ustabuca.edu.co/index.php/USTASALUD_ODONTOLOGIA/article/view/121510.15332/us.v12i2.1215http://hdl.handle.net/11634/37078Objective: to assess In vitro behavior of a passive RFID microchip implanted in human molars and subjected to high temperatures to determine their resistance and performance.Methods: an experimental In vitro study was done to evaluate the behavior of a passive RFID microchip (VeriChip™) implanted in 10 human molars with a composite restoration (Filtek P90™ Silorane 3M-ESPE®) in class I occlusal cavities and class V vestibular cavities and subjected to high temperatures (100 °C, 200 °C, 300 °C, 400 °C and 500 °C), in order to determine their resistance and performance. The specimens were observed through Digital Photography (DP), Stereomicroscopy (SM) and Scanning Electron Microscopy (SEM).Results: it was observed that passive RFID microchips have capacity to withstand high temperatures maintaining their macrostructural integrity, but they were observed cohesive and adhesive fractures that disrupt the mechanisms of adhesion between the dental tissues, the composite material and the microchip, and impairs its correct operation beyond 300 °C.Conclusions: passive RFID microchips implanted in human molars with a resin restoration resist the action of high temperatures without altering their macrostructure, however they only operated up to 300 °C, which eventually may contribute to the processes of forensic identification in case of burned, charred and incinerated bodies.Objetivo: valorar el comportamiento In vitro de un microchip RFID pasivo implantado en molares humanos y sometidos a altas temperaturas para determinar su capacidad de resistencia y funcionamiento.Materiales y métodos: estudio experimental In vitro que evaluó el comportamiento de un microchip RFID pasivo (VeriChip™) implantado en diez molares humanos a través de una restauración en resina (Filtek P90™ Silorane 3M-ESPE®) en cavidades oclusales clase I y vestibulares clase V y sometido a altas temperaturas (100 °C, 200 °C, 300 °C, 400 °C y 500 °C), con el fin de determinar su capacidad de resistencia y funcionamiento. Los especímenes fueron observados a través de Fotografía Digital (FD), Estereomicroscopio (EM) y Microscopio Electrónico de Barrido (MEB).Resultados: se observó que los microchips RFID pasivos tienen capacidad de resistir a las altas temperaturas al conservar su integridad macroestructural; sin embargo, se observaron fracturas cohesivas y adhesivas que alteran los mecanismos de adhesión entre los tejidos dentales, la resina y el microchip, y el correcto funcionamiento de este último a partir de los 300 °C.Conclusiones: los microchips RFID pasivos implantados en molares humanos a través de una restauración en resina resisten la acción de las altas temperaturas sin alterar su macroestructura. No obstante, solo funcionaron hasta los 300 °C; lo que, eventualmente, podrá contribuir con los procesos de identificación forense para el caso de cadáveres quemados, carbonizados e incinerados.[Moreno F, Moreno SM, Garzón H. Microchip RFID pasivo implantado en dientes molares sometidos a altas temperaturas con fines de identificación forense. Ustasalud 2013; 12: 116 - 123]application/pdfspaUniversidad Santo Tomás Seccional Bucaramangahttp://revistas.ustabuca.edu.co/index.php/USTASALUD_ODONTOLOGIA/article/view/1215/1001Ustasalud; Vol. 12 Núm. 2 (2013); 116-123Ustasalud; Vol. 12 Núm. 2 (2013); 116-1232590-78751692-510610.15332/us.v12i2Derechos de autor 2018 UstaSaludhttp://purl.org/coar/access_right/c_abf2MICROCHIP RFID PASIVO IMPLANTADO EN DIENTES MOLARES SOMETIDOS A ALTAS TEMPERATURAS CON FINES DE IDENTIFICACIÓN FORENSEIMPLANTED PASSIVE RFID MICROCHIPS IN MOLARS SUBJECTED TO HIGH TEMPERATURES WITH FORENSIC IDENTIFICATION PURPOSESArtículo revisado por paresinfo:eu-repo/semantics/articlehttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_2df8fbb111634/37078oai:repository.usta.edu.co:11634/370782023-07-14 16:13:40.906metadata only accessRepositorio Universidad Santo Tomásnoreply@usta.edu.co