Simulación numérica de una prueba de reología capilar para un polímero PC+ABS

The aim of this work was to simulate the capillary rheometry test in the Fluent module of the ANSYS Workbech® interface. It was used a series of viscosity data obtained from a capillary rheometry test for a PC + ABS polymer. These data were corrected according to the non-Newtonian behavior of the po...

Full description

Autores:
Jurado Páramo, Jorge
Plascencia Mora, Héctor
Aguilera Gómez, Eduardo
Tipo de recurso:
Fecha de publicación:
2021
Institución:
Universidad Santo Tomás
Repositorio:
Repositorio Institucional USTA
Idioma:
spa
OAI Identifier:
oai:repository.usta.edu.co:11634/41675
Acceso en línea:
http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/2310
http://hdl.handle.net/11634/41675
Palabra clave:
Capillary rheometry
Material model
Simulation
Viscosity
Modelo de material
Reometría capilar
Simulación
Viscosidad
Modelo de material
Reometria capilar
Simulação
Viscosidade
Rights
License
Derechos de autor 2021 Ingenio Magno
id SANTTOMAS2_f509208bfbc0c1120d6a89b4e7167e5a
oai_identifier_str oai:repository.usta.edu.co:11634/41675
network_acronym_str SANTTOMAS2
network_name_str Repositorio Institucional USTA
repository_id_str
dc.title.spa.fl_str_mv Simulación numérica de una prueba de reología capilar para un polímero PC+ABS
dc.title.alternative.eng.fl_str_mv Numerical simulation of a capillary rheometry test for a PC+ABS polymer
dc.title.alternative.por.fl_str_mv Simulação numérica de um teste de reologia capilar para um polímero PC+ABS
title Simulación numérica de una prueba de reología capilar para un polímero PC+ABS
spellingShingle Simulación numérica de una prueba de reología capilar para un polímero PC+ABS
Capillary rheometry
Material model
Simulation
Viscosity
Modelo de material
Reometría capilar
Simulación
Viscosidad
Modelo de material
Reometria capilar
Simulação
Viscosidade
title_short Simulación numérica de una prueba de reología capilar para un polímero PC+ABS
title_full Simulación numérica de una prueba de reología capilar para un polímero PC+ABS
title_fullStr Simulación numérica de una prueba de reología capilar para un polímero PC+ABS
title_full_unstemmed Simulación numérica de una prueba de reología capilar para un polímero PC+ABS
title_sort Simulación numérica de una prueba de reología capilar para un polímero PC+ABS
dc.creator.fl_str_mv Jurado Páramo, Jorge
Plascencia Mora, Héctor
Aguilera Gómez, Eduardo
dc.contributor.author.none.fl_str_mv Jurado Páramo, Jorge
Plascencia Mora, Héctor
Aguilera Gómez, Eduardo
dc.subject.proposal.eng.fl_str_mv Capillary rheometry
Material model
Simulation
Viscosity
topic Capillary rheometry
Material model
Simulation
Viscosity
Modelo de material
Reometría capilar
Simulación
Viscosidad
Modelo de material
Reometria capilar
Simulação
Viscosidade
dc.subject.proposal.spa.fl_str_mv Modelo de material
Reometría capilar
Simulación
Viscosidad
dc.subject.proposal.por.fl_str_mv Modelo de material
Reometria capilar
Simulação
Viscosidade
description The aim of this work was to simulate the capillary rheometry test in the Fluent module of the ANSYS Workbech® interface. It was used a series of viscosity data obtained from a capillary rheometry test for a PC + ABS polymer. These data were corrected according to the non-Newtonian behavior of the polymer. The viscosity data was fitted to the Cross model by the Autodesk® Data Fitting application. The test parameters as geometry, temperature, and the speed of the rheometer piston were used to generate the numerical model in ANSYS Fluent® software. For the numerical model, the geometry was generated, and the boundary conditions were defined. For the geometry, an axisymmetric model was defined. The mesh was generated with a concentration of elements near the walls. When the program finished solving the model, the solution was analyzed. It was compared the pressure value from simulation with the pressure value from the physical test, and a correlation coefficient of 0.999 was obtained.
publishDate 2021
dc.date.issued.none.fl_str_mv 2021-07-26
dc.date.accessioned.none.fl_str_mv 2022-01-18T21:47:58Z
dc.date.available.none.fl_str_mv 2022-01-18T21:47:58Z
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.drive.none.fl_str_mv info:eu-repo/semantics/article
dc.identifier.none.fl_str_mv http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/2310
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/11634/41675
url http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/2310
http://hdl.handle.net/11634/41675
dc.language.iso.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/2310/1965
dc.relation.citationissue.spa.fl_str_mv Ingenio Magno; Vol. 12 Núm. 1 (2021): Ingenio Magno vol. 12-1; 66-76
dc.relation.citationissue.none.fl_str_mv 2422-2399
2145-9282
dc.rights.spa.fl_str_mv Derechos de autor 2021 Ingenio Magno
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Derechos de autor 2021 Ingenio Magno
http://purl.org/coar/access_right/c_abf2
dc.format.mimetype.none.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Santo Tomás Seccional Tunja
institution Universidad Santo Tomás
repository.name.fl_str_mv Repositorio Universidad Santo Tomás
repository.mail.fl_str_mv noreply@usta.edu.co
_version_ 1782026101565947904
spelling Jurado Páramo, JorgePlascencia Mora, HéctorAguilera Gómez, Eduardo2022-01-18T21:47:58Z2022-01-18T21:47:58Z2021-07-26http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/2310http://hdl.handle.net/11634/41675The aim of this work was to simulate the capillary rheometry test in the Fluent module of the ANSYS Workbech® interface. It was used a series of viscosity data obtained from a capillary rheometry test for a PC + ABS polymer. These data were corrected according to the non-Newtonian behavior of the polymer. The viscosity data was fitted to the Cross model by the Autodesk® Data Fitting application. The test parameters as geometry, temperature, and the speed of the rheometer piston were used to generate the numerical model in ANSYS Fluent® software. For the numerical model, the geometry was generated, and the boundary conditions were defined. For the geometry, an axisymmetric model was defined. The mesh was generated with a concentration of elements near the walls. When the program finished solving the model, the solution was analyzed. It was compared the pressure value from simulation with the pressure value from the physical test, and a correlation coefficient of 0.999 was obtained.El objetivo de este trabajo fue simular la prueba de reometría capilar en el módulo de Fluent® en la interfaz de ANSYS Workbech®. Se partió de una serie de datos de viscosidad obtenidos de una prueba de reometría capilar para un polímero PC+ABS. Estos datos fueron corregidos conforme al comportamiento no Newtoniano que presenta el polímero. Se hizo un ajuste de los datos al modelo de Cross mediante una aplicación Data Fitting de Autodesk®. Se generó el modelo numérico en función de los datos de la prueba: tipo y tamaño de geometría, temperatura y velocidad de avance del pistón del reómetro, en el software comercial ANSYS Fluent®. Estos datos se utilizaron para la creación de la geometría y la aplicación de condiciones de frontera del modelo numérico. Para la geometría se utilizó un caso axisimétrico al que se le generó la malla con concentración de elementos cerca de las paredes. Después de resolver se comparó el valor de presión obtenido en la simulación contra el valor reportado por la prueba física y se observó un coeficiente de correlación de 0.999 entre los dos grupos de datos.O objetivo deste trabalho foi simular o teste de reometria capilar no módulo Fluent da interface ANSYS Workbech®. Ele foi iniciado a partir de uma série de dados de viscosidade obtidos de um teste de reometria capilar para um polímero PC + ABS. Esses dados foram corrigidos de acordo com o comportamento não newtoniano do polímero. Os dados foram ajustados ao modelo Cross usando um aplicativo Autodesk® Data Fitting. O modelo numérico foi gerado com base nos dados de teste: tipo e tamanho da geometria, temperatura e velocidade de avanço do pistão do reômetro, no software comercial ANSYS Fluent®. Esses dados foram usados ​​para a criação da geometria e aplicação das condições de contorno do modelo numérico. Para a geometria, foi utilizado um caso axissimétrico em que a malha foi gerada com uma concentração de elementos próximos às paredes. Após a resolução, o valor da pressão obtido na simulação foi comparado com o valor reportado pelo teste físico e foi observado um coeficiente de correlação de 0,999 entre os dois grupos de dados.application/pdfspaUniversidad Santo Tomás Seccional Tunjahttp://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/2310/1965Ingenio Magno; Vol. 12 Núm. 1 (2021): Ingenio Magno vol. 12-1; 66-762422-23992145-9282Derechos de autor 2021 Ingenio Magnohttp://purl.org/coar/access_right/c_abf2Simulación numérica de una prueba de reología capilar para un polímero PC+ABSNumerical simulation of a capillary rheometry test for a PC+ABS polymerSimulação numérica de um teste de reologia capilar para um polímero PC+ABSinfo:eu-repo/semantics/articlehttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_2df8fbb1Capillary rheometryMaterial modelSimulationViscosityModelo de materialReometría capilarSimulaciónViscosidadModelo de materialReometria capilarSimulaçãoViscosidade11634/41675oai:repository.usta.edu.co:11634/416752023-07-14 16:21:02.511metadata only accessRepositorio Universidad Santo Tomásnoreply@usta.edu.co