Modos de falla en anclajes epóxicos post-instalados en concretos pobres, sometidos a ensayos de tracción directa

In our country, the study of failure modes in post-installed anchors has been limited to common concrete resistances, this paper aims to identify the types of failures associated with tested epoxy anchors, and interpret the faults based on existing classifications. The methodology used is based on b...

Full description

Autores:
Bermúdez Morales, William H
Páez Moreno, Diego Fernando
Tipo de recurso:
Fecha de publicación:
2018
Institución:
Universidad Santo Tomás
Repositorio:
Repositorio Institucional USTA
Idioma:
spa
OAI Identifier:
oai:repository.usta.edu.co:11634/12279
Acceso en línea:
http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/1504
Palabra clave:
engineering, construction, civil
Adhesion; Epoxy Anchor; Concrete; Post-Installed; Testing; Traction
ingenieria, contrucción, civil
Adherencia; Anclaje Epóxico; Concreto; Post-Instalado; Probetas; Tracción
engenharia, construção civil
Aderência; âncora epóxi; concreto; pós-instalado; tubos de ensaio; Tração
Rights
License
Copyright (c) 2018 Ingenio Magno
id SANTTOMAS2_635eba586e43f3d884bb67cafcab530e
oai_identifier_str oai:repository.usta.edu.co:11634/12279
network_acronym_str SANTTOMAS2
network_name_str Repositorio Institucional USTA
repository_id_str
dc.title.spa.fl_str_mv Modos de falla en anclajes epóxicos post-instalados en concretos pobres, sometidos a ensayos de tracción directa
dc.title.alternative.eng.fl_str_mv Failure modes of postinstalled epoxy anchors in poor concrete, submitted to direct traction tests
dc.title.alternative.por.fl_str_mv Modos de falha de ancoragens de epoxia post-instalados em poço de betão, submitido para testes de tracção directos
title Modos de falla en anclajes epóxicos post-instalados en concretos pobres, sometidos a ensayos de tracción directa
spellingShingle Modos de falla en anclajes epóxicos post-instalados en concretos pobres, sometidos a ensayos de tracción directa
engineering, construction, civil
Adhesion; Epoxy Anchor; Concrete; Post-Installed; Testing; Traction
ingenieria, contrucción, civil
Adherencia; Anclaje Epóxico; Concreto; Post-Instalado; Probetas; Tracción
engenharia, construção civil
Aderência; âncora epóxi; concreto; pós-instalado; tubos de ensaio; Tração
title_short Modos de falla en anclajes epóxicos post-instalados en concretos pobres, sometidos a ensayos de tracción directa
title_full Modos de falla en anclajes epóxicos post-instalados en concretos pobres, sometidos a ensayos de tracción directa
title_fullStr Modos de falla en anclajes epóxicos post-instalados en concretos pobres, sometidos a ensayos de tracción directa
title_full_unstemmed Modos de falla en anclajes epóxicos post-instalados en concretos pobres, sometidos a ensayos de tracción directa
title_sort Modos de falla en anclajes epóxicos post-instalados en concretos pobres, sometidos a ensayos de tracción directa
dc.creator.fl_str_mv Bermúdez Morales, William H
Páez Moreno, Diego Fernando
dc.contributor.author.spa.fl_str_mv Bermúdez Morales, William H
Páez Moreno, Diego Fernando
dc.subject.proposal.eng.fl_str_mv engineering, construction, civil
Adhesion; Epoxy Anchor; Concrete; Post-Installed; Testing; Traction
topic engineering, construction, civil
Adhesion; Epoxy Anchor; Concrete; Post-Installed; Testing; Traction
ingenieria, contrucción, civil
Adherencia; Anclaje Epóxico; Concreto; Post-Instalado; Probetas; Tracción
engenharia, construção civil
Aderência; âncora epóxi; concreto; pós-instalado; tubos de ensaio; Tração
dc.subject.proposal.spa.fl_str_mv ingenieria, contrucción, civil
Adherencia; Anclaje Epóxico; Concreto; Post-Instalado; Probetas; Tracción
dc.subject.proposal.por.fl_str_mv engenharia, construção civil
Aderência; âncora epóxi; concreto; pós-instalado; tubos de ensaio; Tração
description In our country, the study of failure modes in post-installed anchors has been limited to common concrete resistances, this paper aims to identify the types of failures associated with tested epoxy anchors, and interpret the faults based on existing classifications. The methodology used is based on building post-installed anchors in poor concrete and submitting them to a direct tensile test in the laboratory, analyzing the failure modes presented and determining the possible causes that originate the failure. As a result, any anchor reaches the yield strength of steel or steel failure, the cone failure mode presents the highest load resistance obtained in direct tensile tests. In general, the use of post-installed epoxy anchors with smaller bar diameters is not recommended, the failure modes observed in anchors with small steels are related to low applied load resistances.
publishDate 2018
dc.date.issued.spa.fl_str_mv 2018-06-02
dc.type.coarversion.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.drive.none.fl_str_mv info:eu-repo/semantics/article
dc.identifier.spa.fl_str_mv http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/1504
url http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/1504
dc.language.iso.spa.fl_str_mv spa
language spa
dc.relation.spa.fl_str_mv http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/1504/1381
dc.relation.citationissue.spa.fl_str_mv Ingenio Magno; Vol. 8, Núm. 2 (2017): Ingenio Magno vol. 8-2; 56 - 68
2422-2399
2145-9282
dc.rights.spa.fl_str_mv Copyright (c) 2018 Ingenio Magno
dc.rights.coar.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Copyright (c) 2018 Ingenio Magno
http://purl.org/coar/access_right/c_abf2
dc.format.mimetype.spa.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Santo Tomás Seccional Tunja
institution Universidad Santo Tomás
repository.name.fl_str_mv Repositorio Universidad Santo Tomás
repository.mail.fl_str_mv noreply@usta.edu.co
_version_ 1782026250626269184
spelling Bermúdez Morales, William HPáez Moreno, Diego Fernando2018-06-02http://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/1504In our country, the study of failure modes in post-installed anchors has been limited to common concrete resistances, this paper aims to identify the types of failures associated with tested epoxy anchors, and interpret the faults based on existing classifications. The methodology used is based on building post-installed anchors in poor concrete and submitting them to a direct tensile test in the laboratory, analyzing the failure modes presented and determining the possible causes that originate the failure. As a result, any anchor reaches the yield strength of steel or steel failure, the cone failure mode presents the highest load resistance obtained in direct tensile tests. In general, the use of post-installed epoxy anchors with smaller bar diameters is not recommended, the failure modes observed in anchors with small steels are related to low applied load resistances.En nuestro país, el estudio de modos de falla en anclajes post-instalados, ha sido limitado a concretos de resistencias comunes. Este escrito tiene como objetivo identificar los tipos de fallas asociados a anclajes epóxicos ensayados, e interpretar las fallas en base a clasificaciones existentes. La metodología utilizada se basa en construir anclajes post-instalados en concretos pobres y someterlos en laboratorio a un ensayo de tracción directa, analizar los modos de falla presentados y determinar las posibles causas que motivan la falla. Como resultados, ningún anclaje alcanza el límite de fluencia del acero o falla de acero, el modo de falla cono de concreto presenta la resistencia de carga más alta obtenida en los ensayos de tracción directa. De manera general, no se recomienda el uso de los anclajes epóxicos post-instalados con diámetros de barras menores, los modos de falla observados en anclajes con aceros pequeños se relacionan a resistencias bajas de carga aplicada.Em nosso país, o estudo dos modos de falha em âncoras pós-instaladas foi limitado a resistências de resistência ao concreto, O objetivo deste trabalho é identificar os tipos de falhas associadas às âncoras epóxi testadas e interpretar as falhas com base nas classificações existentes. A metodologia utilizada baseia-se na construção de âncoras pós-instaladas em concreto pobre e submete-as a um teste de tração direta em laboratório, analise os modos de falha apresentados e determine as possíveis causas que causam a falha. Como resultado, nenhuma âncora atinge o limite de elasticidade da falha de aço ou aço, O modo de falha do cone de concreto apresenta a maior resistência de carga obtida nos testes de tração direta. Em geral, o uso de âncoras epóxi pós-instaladas com diâmetros de barras menores não é recomendado, Os modos de falha observados nas âncoras com aços pequenos estão relacionados à baixa resistência da carga aplicada.application/pdfspaUniversidad Santo Tomás Seccional Tunjahttp://revistas.ustatunja.edu.co/index.php/ingeniomagno/article/view/1504/1381Ingenio Magno; Vol. 8, Núm. 2 (2017): Ingenio Magno vol. 8-2; 56 - 682422-23992145-9282Copyright (c) 2018 Ingenio Magnohttp://purl.org/coar/access_right/c_abf2Modos de falla en anclajes epóxicos post-instalados en concretos pobres, sometidos a ensayos de tracción directaFailure modes of postinstalled epoxy anchors in poor concrete, submitted to direct traction testsModos de falha de ancoragens de epoxia post-instalados em poço de betão, submitido para testes de tracção directosinfo:eu-repo/semantics/articlehttp://purl.org/coar/version/c_970fb48d4fbd8a85http://purl.org/coar/resource_type/c_2df8fbb1engineering, construction, civilAdhesion; Epoxy Anchor; Concrete; Post-Installed; Testing; Tractioningenieria, contrucción, civilAdherencia; Anclaje Epóxico; Concreto; Post-Instalado; Probetas; Tracciónengenharia, construção civilAderência; âncora epóxi; concreto; pós-instalado; tubos de ensaio; Tração11634/12279oai:repository.usta.edu.co:11634/122792023-07-14 16:37:43.322metadata only accessRepositorio Universidad Santo Tomásnoreply@usta.edu.co