Análisis de factores de confort acústico y su relación con variables de ventilación de entrada en aulas de instituciones educativas ubicadas en ciudades de clima tropical (caso de estudio Medellín)
The following research framed within the research project "Identification of factors of environmental performance (acoustic, thermal and visual) determinants of the mental health of teachers and students of public schools in Bogotá, Medellín and Cali, evaluates some variables of the current con...
- Autores:
-
Rendón Giraldo, Jeiser
- Tipo de recurso:
- Fecha de publicación:
- 2018
- Institución:
- Universidad de San Buenaventura
- Repositorio:
- Repositorio USB
- Idioma:
- spa
- OAI Identifier:
- oai:bibliotecadigital.usb.edu.co:10819/6038
- Acceso en línea:
- http://hdl.handle.net/10819/6038
- Palabra clave:
- Confort
Aulas
Trópico
Acoustics
Ventilation
Classrooms
Tropics
Ventanas (acústica)
Medición acústicas
Acústica
Ventilación
Acústica en arquitectura
Ruido en edificaciones
- Rights
- License
- Atribución-NoComercial-SinDerivadas 2.5 Colombia
Summary: | The following research framed within the research project "Identification of factors of environmental performance (acoustic, thermal and visual) determinants of the mental health of teachers and students of public schools in Bogotá, Medellín and Cali, evaluates some variables of the current conditions of acoustic comfort and ventilation that public educational institutions of Medellin and the impact of ventilation on acoustic comfort. The analysis starts from the question that arises, before the educational buildings developed after the year 2000, year in which the Colombian Technical Norm NTC4595 "Approach and design of school facilities and environments" was published. It becomes relevant in this investigation to know the conditions of comfort in the educational classrooms and to evaluate the adoption of its content by the construction sector. The methodology used for this research, takes as sample 3 educational institutions, in which 7 classrooms were measured, from each classroom the building, geographical, acoustic information and the typology of the openings used for natural ventilation were raised. In addition, other quantitative variables that could help to clarify the results as they were (internal temperature, internal air velocity at the entrance of the opening, relative humidity and atmospheric pressure). In the analysis of results, it was found that a large percentage of the classrooms comply with the ventilation parameters established by NTC4595 (effective area of ventilation and height); but, they overcome the acoustic variables (background noise, reverberation time and transmission loss). |
---|