Quantification of two isomeric flavones in rat colon tissue using reverse phase high performance liquid chromatography
Background: Antineoplastic activity has been previously shown for two isomeric flavones, 5,7-dihydroxy-3,6,8-trimethoxy flavone (flavone A) and 3,5-dihydroxy-6,7,8-trimethoxy flavone (flavone B), against colon cancer cell lines (Thomas et al. in PLoS ONE 7:e39806, 5). Here, we present modified metho...
- Autores:
-
Whitted, Crystal L.
Palau, Victoria E.
Torrenegra, Rubén D.
Rodrigez, Oscar E.
Harirforoosh, Sam
- Tipo de recurso:
- Article of journal
- Fecha de publicación:
- 2017
- Institución:
- Universidad de Ciencias Aplicadas y Ambientales U.D.C.A
- Repositorio:
- Repositorio Institucional UDCA
- Idioma:
- eng
- OAI Identifier:
- oai:repository.udca.edu.co:11158/2412
- Palabra clave:
- Helichrysum
Aceites Volátiles
Cromatografía Líquida de Alta Presión
Calibración
Línea Celular Tumoral
Cromatografía de Fase Inversa
Flavonas
Helichrysum
Olis volatile
Chromatography, High Pressure Liquid
Calibration
Cell Line, Tumor
Chromatography, Reverse-Phase
Flavones
- Rights
- openAccess
- License
- Derechos Reservados - Universidad de Ciencias Aplicadas y Ambientales
Summary: | Background: Antineoplastic activity has been previously shown for two isomeric flavones, 5,7-dihydroxy-3,6,8-trimethoxy flavone (flavone A) and 3,5-dihydroxy-6,7,8-trimethoxy flavone (flavone B), against colon cancer cell lines (Thomas et al. in PLoS ONE 7:e39806, 5). Here, we present modified methods for the extraction and quantification of flavones A and B in rat colon tissue after intravenous dosing via high performance liquid chromatography, from the originally described procedure for extraction and quantification in rat plasma (Whitted et al. in J Chromatogr B Analyt Technol Biomed Life Sci 1001:150-155, 7). Results: Modifications included tissue homogenization (1 g tissue: 2 mL water), filtration of the supernatant with a PVDF membrane, and the use of only one calibration curve to determine the concentration of each flavone in colon tissue. Good separation was achieved and representative equations were linear with r 2 ≥ 0.99 for both flavones. Precision and accuracy for flavone A ranged from 0.88-24.03 and 109-116%. Precision and accuracy for flavone B ranged from 1.62-33.56 and 98-113%. Concentrations of 1639 ± 601 ng/g flavone A and 5975 ± 2480 ng/g of flavone B were detected in rat colon tissue 6 h post dosing. Conclusions: Modifications to the extraction methods for flavone A and flavone B from rat colon tissue had good separation, precision, and accuracy |
---|