Cascade dc/dc Converters for Efficiency Improvement and low Harmonic Content: Experimental Validation

This paper presents the experimental validation of the benefits providedby the cascade configuration of dc/dc converters over classical single dc/dc converters. The results obtained prove that the cascade connection ofdc/dc converters, despite insert additional parasitic resistances, improvesthe vol...

Full description

Autores:
Tipo de recurso:
Article of journal
Fecha de publicación:
2019
Institución:
Universidad Católica de Pereira
Repositorio:
Repositorio Institucional - RIBUC
Idioma:
spa
OAI Identifier:
oai:repositorio.ucp.edu.co:10785/9905
Acceso en línea:
https://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/730
http://hdl.handle.net/10785/9905
Palabra clave:
Rights
openAccess
License
Derechos de autor 2019 Entre Ciencia e Ingeniería
id RepoRIBUC2_79dbf7b7c993317118fc36be97e9b7c4
oai_identifier_str oai:repositorio.ucp.edu.co:10785/9905
network_acronym_str RepoRIBUC2
network_name_str Repositorio Institucional - RIBUC
repository_id_str
spelling 2022-06-01T19:08:49Z2022-06-01T19:08:49Z2019-08-01https://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/730http://hdl.handle.net/10785/9905This paper presents the experimental validation of the benefits providedby the cascade configuration of dc/dc converters over classical single dc/dc converters. The results obtained prove that the cascade connection ofdc/dc converters, despite insert additional parasitic resistances, improvesthe voltage conversion ratio and efficiency of a step-up conversion chain.In addition, the adopted cascade configuration also reduces the currentharmonics injected to sensible power sources like fuel cells or photovoltaicgenerators. Finally, a simple procedure to experimentally identify theinductor parasitic loss resistance on boost converters was also introduced.Este artículo presenta la validación experimental de los beneficios ofrecidos por la conexión en cascada de convertidores dc/dc sobre los convertidores dc/dc clásicos. Los resultados obtenidos prueban que la conexión en cascada de convertidores dc/dc, a pesar de insertar resistencias parásitas adicionales, incrementa la relación de transformación de voltaje y la eficiencia de un sistema de conversión. Además, la configuración en cascada seleccionada reduce el contenido armónico inyectado a fuentes de potencia sensibles como pilas de combustible y paneles fotovoltaicos. Finalmente, se presenta un procedimiento simple para identificar experimentalmente la resistencia parásita del inductor en un convertidor elevador.application/pdfspaUniversidad Católica de Pereirahttps://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/730/726Derechos de autor 2019 Entre Ciencia e Ingenieríahttps://creativecommons.org/licenses/by-nc/4.0/deed.es_EShttps://creativecommons.org/licenses/by-nc/4.0/deed.es_ESinfo:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Entre ciencia e ingeniería; Vol 5 No 10 (2011); 121-133Entre Ciencia e Ingeniería; Vol. 5 Núm. 10 (2011); 121-133Entre ciencia e ingeniería; v. 5 n. 10 (2011); 121-1332539-41691909-8367Cascade dc/dc Converters for Efficiency Improvement and low Harmonic Content: Experimental ValidationConvertidores dc/dc en cascada para incremento de eficiencia y reducción de contenido armónico: Validación experimental.Artículo de revistahttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPaniagua Palacio, Laur CristinaRamírez Álvarez, Iván JoséRamos Paja, Carlos AndrésPublication10785/9905oai:repositorio.ucp.edu.co:10785/99052025-01-27 19:00:57.24https://creativecommons.org/licenses/by-nc/4.0/deed.es_ESDerechos de autor 2019 Entre Ciencia e Ingenieríametadata.onlyhttps://repositorio.ucp.edu.coRepositorio Institucional de la Universidad Católica de Pereira - RIBUCbdigital@metabiblioteca.com
dc.title.eng.fl_str_mv Cascade dc/dc Converters for Efficiency Improvement and low Harmonic Content: Experimental Validation
dc.title.spa.fl_str_mv Convertidores dc/dc en cascada para incremento de eficiencia y reducción de contenido armónico: Validación experimental.
title Cascade dc/dc Converters for Efficiency Improvement and low Harmonic Content: Experimental Validation
spellingShingle Cascade dc/dc Converters for Efficiency Improvement and low Harmonic Content: Experimental Validation
title_short Cascade dc/dc Converters for Efficiency Improvement and low Harmonic Content: Experimental Validation
title_full Cascade dc/dc Converters for Efficiency Improvement and low Harmonic Content: Experimental Validation
title_fullStr Cascade dc/dc Converters for Efficiency Improvement and low Harmonic Content: Experimental Validation
title_full_unstemmed Cascade dc/dc Converters for Efficiency Improvement and low Harmonic Content: Experimental Validation
title_sort Cascade dc/dc Converters for Efficiency Improvement and low Harmonic Content: Experimental Validation
description This paper presents the experimental validation of the benefits providedby the cascade configuration of dc/dc converters over classical single dc/dc converters. The results obtained prove that the cascade connection ofdc/dc converters, despite insert additional parasitic resistances, improvesthe voltage conversion ratio and efficiency of a step-up conversion chain.In addition, the adopted cascade configuration also reduces the currentharmonics injected to sensible power sources like fuel cells or photovoltaicgenerators. Finally, a simple procedure to experimentally identify theinductor parasitic loss resistance on boost converters was also introduced.
publishDate 2019
dc.date.issued.none.fl_str_mv 2019-08-01
dc.date.accessioned.none.fl_str_mv 2022-06-01T19:08:49Z
dc.date.available.none.fl_str_mv 2022-06-01T19:08:49Z
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.coar.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.none.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driver.none.fl_str_mv info:eu-repo/semantics/article
dc.type.version.none.fl_str_mv info:eu-repo/semantics/publishedVersion
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/730
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/10785/9905
url https://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/730
http://hdl.handle.net/10785/9905
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/730/726
dc.rights.spa.fl_str_mv Derechos de autor 2019 Entre Ciencia e Ingeniería
https://creativecommons.org/licenses/by-nc/4.0/deed.es_ES
dc.rights.uri.spa.fl_str_mv https://creativecommons.org/licenses/by-nc/4.0/deed.es_ES
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Derechos de autor 2019 Entre Ciencia e Ingeniería
https://creativecommons.org/licenses/by-nc/4.0/deed.es_ES
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.spa.fl_str_mv Universidad Católica de Pereira
dc.source.eng.fl_str_mv Entre ciencia e ingeniería; Vol 5 No 10 (2011); 121-133
dc.source.spa.fl_str_mv Entre Ciencia e Ingeniería; Vol. 5 Núm. 10 (2011); 121-133
dc.source.por.fl_str_mv Entre ciencia e ingeniería; v. 5 n. 10 (2011); 121-133
dc.source.none.fl_str_mv 2539-4169
1909-8367
institution Universidad Católica de Pereira
repository.name.fl_str_mv Repositorio Institucional de la Universidad Católica de Pereira - RIBUC
repository.mail.fl_str_mv bdigital@metabiblioteca.com
_version_ 1834112780211322880