Use of Viscous Fluid Dissipators as a measure of Structural Reinforcement

Peru, a country with high seismicity throughout its history, currently shows an absence of large-magnitude earthquakes, so it is a priority to analyze existing structures and influence whether any intervention is required to improve their earthquake-resistant behavior, the main purpose of This resea...

Full description

Autores:
Tipo de recurso:
Article of journal
Fecha de publicación:
2023
Institución:
Universidad Católica de Pereira
Repositorio:
Repositorio Institucional - RIBUC
Idioma:
spa
OAI Identifier:
oai:repositorio.ucp.edu.co:10785/13709
Acceso en línea:
https://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/2757
http://hdl.handle.net/10785/13709
Palabra clave:
Rights
openAccess
License
Derechos de autor 2023 Entre Ciencia e Ingeniería
id RepoRIBUC2_437bcbb2a713f52492d88e3f8fa9f437
oai_identifier_str oai:repositorio.ucp.edu.co:10785/13709
network_acronym_str RepoRIBUC2
network_name_str Repositorio Institucional - RIBUC
repository_id_str
spelling 2023-08-29T03:49:42Z2023-08-29T03:49:42Z2023-01-02https://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/275710.31908/19098367.2757http://hdl.handle.net/10785/13709Peru, a country with high seismicity throughout its history, currently shows an absence of large-magnitude earthquakes, so it is a priority to analyze existing structures and influence whether any intervention is required to improve their earthquake-resistant behavior, the main purpose of This research project was to estimate if these devices are suitable for use as a measure of structural reinforcement, the present research project is of the applied - evaluative type, showing favorable results that would validate its use, adding a viscous damping greater than 15%, thus dissipating the seismic energy by more than 85%; reducing lateral displacements and internal forces in vertical elements such as columns and shear walls between 50% and 80%, therefore these elements would require less areas of steel, being an additional advantage its easy implementation compared to traditional reinforcement methods, confirming that they are suitable for use as a reinforcement measure.Perú un país de alta sismicidad a lo largo de su historia muestra en la actualidad ausencia de sismos de gran magnitud, por lo que es de prioridad analizar las estructuras existentes e influir si se requiere alguna intervención que mejore su comportamiento sismorresistente. El propósito principal de este proyecto investigativo es estimar si estos dispositivos son aptos para su uso como medida de reforzamiento estructural, es un proyecto de tipo aplicado – evaluativo, el cual muestra resultados favorables que validarían su uso, adicionando un amortiguamiento viscoso mayor al 15%, disipando así la energía sísmica en más del 85%; reduciendo los desplazamientos laterales y esfuerzos internos en los elementos verticales como columnas y muros de corte entre un 50% y 80%, por lo tanto, estos elementos requerirían menores áreas de acero, siendo una ventaja adicional su fácil implementación comparado a los métodos tradicionales de reforzamiento, confirmando que son adecuados para su uso como medida de reforzamiento.application/pdfapplication/xmlspaUniversidad Católica de Pereirahttps://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/2757/2600https://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/2757/2635Derechos de autor 2023 Entre Ciencia e Ingenieríahttps://creativecommons.org/licenses/by-nc/4.0/deed.es_EShttps://creativecommons.org/licenses/by-nc/4.0/deed.es_ESinfo:eu-repo/semantics/openAccesshttp://purl.org/coar/access_right/c_abf2Entre ciencia e ingeniería; Vol 16 No 32 (2022); 52-57Entre Ciencia e Ingeniería; Vol. 16 Núm. 32 (2022); 52-57Entre ciencia e ingeniería; v. 16 n. 32 (2022); 52-572539-41691909-8367Use of Viscous Fluid Dissipators as a measure of Structural ReinforcementUso de Disipadores de Fluido Viscoso como medida de Reforzamiento EstructuralArtículo de revistahttp://purl.org/coar/resource_type/c_6501http://purl.org/coar/resource_type/c_2df8fbb1http://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionMuñoz Pérez, Sócrates PedroCuyán Barboza, Arlinton EdwinPublication10785/13709oai:repositorio.ucp.edu.co:10785/137092025-01-27 18:58:33.408https://creativecommons.org/licenses/by-nc/4.0/deed.es_ESDerechos de autor 2023 Entre Ciencia e Ingenieríametadata.onlyhttps://repositorio.ucp.edu.coRepositorio Institucional de la Universidad Católica de Pereira - RIBUCbdigital@metabiblioteca.com
dc.title.eng.fl_str_mv Use of Viscous Fluid Dissipators as a measure of Structural Reinforcement
dc.title.spa.fl_str_mv Uso de Disipadores de Fluido Viscoso como medida de Reforzamiento Estructural
title Use of Viscous Fluid Dissipators as a measure of Structural Reinforcement
spellingShingle Use of Viscous Fluid Dissipators as a measure of Structural Reinforcement
title_short Use of Viscous Fluid Dissipators as a measure of Structural Reinforcement
title_full Use of Viscous Fluid Dissipators as a measure of Structural Reinforcement
title_fullStr Use of Viscous Fluid Dissipators as a measure of Structural Reinforcement
title_full_unstemmed Use of Viscous Fluid Dissipators as a measure of Structural Reinforcement
title_sort Use of Viscous Fluid Dissipators as a measure of Structural Reinforcement
description Peru, a country with high seismicity throughout its history, currently shows an absence of large-magnitude earthquakes, so it is a priority to analyze existing structures and influence whether any intervention is required to improve their earthquake-resistant behavior, the main purpose of This research project was to estimate if these devices are suitable for use as a measure of structural reinforcement, the present research project is of the applied - evaluative type, showing favorable results that would validate its use, adding a viscous damping greater than 15%, thus dissipating the seismic energy by more than 85%; reducing lateral displacements and internal forces in vertical elements such as columns and shear walls between 50% and 80%, therefore these elements would require less areas of steel, being an additional advantage its easy implementation compared to traditional reinforcement methods, confirming that they are suitable for use as a reinforcement measure.
publishDate 2023
dc.date.accessioned.none.fl_str_mv 2023-08-29T03:49:42Z
dc.date.available.none.fl_str_mv 2023-08-29T03:49:42Z
dc.date.issued.none.fl_str_mv 2023-01-02
dc.type.spa.fl_str_mv Artículo de revista
dc.type.coar.fl_str_mv http://purl.org/coar/resource_type/c_2df8fbb1
dc.type.coar.none.fl_str_mv http://purl.org/coar/resource_type/c_6501
dc.type.coarversion.none.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driver.none.fl_str_mv info:eu-repo/semantics/article
dc.type.version.none.fl_str_mv info:eu-repo/semantics/publishedVersion
format http://purl.org/coar/resource_type/c_6501
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/2757
10.31908/19098367.2757
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/10785/13709
url https://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/2757
http://hdl.handle.net/10785/13709
identifier_str_mv 10.31908/19098367.2757
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/2757/2600
https://revistas.ucp.edu.co/index.php/entrecienciaeingenieria/article/view/2757/2635
dc.rights.spa.fl_str_mv Derechos de autor 2023 Entre Ciencia e Ingeniería
https://creativecommons.org/licenses/by-nc/4.0/deed.es_ES
dc.rights.uri.spa.fl_str_mv https://creativecommons.org/licenses/by-nc/4.0/deed.es_ES
dc.rights.accessrights.spa.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.coar.spa.fl_str_mv http://purl.org/coar/access_right/c_abf2
rights_invalid_str_mv Derechos de autor 2023 Entre Ciencia e Ingeniería
https://creativecommons.org/licenses/by-nc/4.0/deed.es_ES
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/xml
dc.publisher.spa.fl_str_mv Universidad Católica de Pereira
dc.source.eng.fl_str_mv Entre ciencia e ingeniería; Vol 16 No 32 (2022); 52-57
dc.source.spa.fl_str_mv Entre Ciencia e Ingeniería; Vol. 16 Núm. 32 (2022); 52-57
dc.source.por.fl_str_mv Entre ciencia e ingeniería; v. 16 n. 32 (2022); 52-57
dc.source.none.fl_str_mv 2539-4169
1909-8367
institution Universidad Católica de Pereira
repository.name.fl_str_mv Repositorio Institucional de la Universidad Católica de Pereira - RIBUC
repository.mail.fl_str_mv bdigital@metabiblioteca.com
_version_ 1828143387527610368