Optimization of the auxiliary ventilation system, based on experiments executed on a ventilation test bench for mines

In this study, the simulation results of the parameters concerning mine ventilation on a test bench are presented. Said investigation incorporated the previous design and implementation of a monitoring system at the laboratory. This was in order to calculate the fan efficiency, based on electrical m...

Full description

Autores:
Castro Duque, Yesid
Tipo de recurso:
Article of journal
Fecha de publicación:
2018
Institución:
UNIVERSIDAD FRANCISCO DE PAULA SANTANDER
Repositorio:
Repositorio Digital UFPS
Idioma:
eng
OAI Identifier:
oai:repositorio.ufps.edu.co:ufps/621
Acceso en línea:
http://repositorio.ufps.edu.co/handle/ufps/621
https://doi.org/10.15446/dyna.v85n207.64255
Palabra clave:
fan performance
ventilation bench
temperature
humidity
pressure
rendimiento del ventilador
banco de ventilación
temperatura
humedad
presión
Rights
openAccess
License
Atribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
Description
Summary:In this study, the simulation results of the parameters concerning mine ventilation on a test bench are presented. Said investigation incorporated the previous design and implementation of a monitoring system at the laboratory. This was in order to calculate the fan efficiency, based on electrical measurements, and fluid mechanics (Bernoulli theory), and whose results can be observed in real time on a computer or through other similar means. The designed system monitors parameters present in the atmosphere of the test bench’s duct, such as temperature, air pressure, methane gas concentration, and electrical variables like voltage and current. The aforementioned observation is done through a graphical interface designed with LabView 2011 software. Tests were performed varying the accessories. The reduction percentage, allows one to infer that the duct section was adequately designed.